scholarly journals Experimental and analytical investigation on high performance concrete-filled steel tube stub columns under axial load

2021 ◽  
Vol 1136 (1) ◽  
pp. 012014
Author(s):  
B Harini ◽  
N Lingeshwaran ◽  
I Siva Kishore
2019 ◽  
Vol 23 (5) ◽  
pp. 969-978
Author(s):  
Jian-gang Wei ◽  
Jun Zhou ◽  
Jiang-nan Huang ◽  
Hui-hui Yuan ◽  
Qing-wei Huang

This article experimentally investigates the cyclic behavior of ultra high performance concrete–filled steel tube beam-columns. A total of eight specimens were tested. The considered parameters were the axial load ratio and steel ratio. The results showed that all ultra high performance concrete–filled steel tube beam-columns had a very good cyclic behavior without significant pinching. Increasing the axial load ratio results in the decrease of strength and ductility, but it has no obvious influence on the initial flexural stiffness. Reducing the steel ratio results in the decrease of the strength, stiffness and ductility, and energy dissipation capacity.


2020 ◽  
Vol 114 ◽  
pp. 103813
Author(s):  
Peiliang Shen ◽  
Jian-Xin Lu ◽  
Haibing Zheng ◽  
Linnu Lu ◽  
Fazhou Wang ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-18
Author(s):  
Jing Ji ◽  
Maomao Yang ◽  
Zhichao Xu ◽  
Liangqin Jiang ◽  
Huayu Song

The behavior of H-shaped honeycombed stub columns with rectangular concrete-filled steel tube flanges (STHCCs) subjected to axial load was investigated experimentally. A total of 16 specimens were studied, and the main parameters varied in the tests included the confinement effect coefficient of the steel tube (ξ), the concrete cubic compressive strength (fcu), the steel web thickness (t2), and the slenderness ratio of specimens (λs). Failure modes, load-displacement curves, load-strain curves of the steel tube flanges and webs, and force mechanisms were obtained by means of axial compression tests. The parameter influences on the axial compression bearing capacity and ductility were then analyzed. The results showed that rudder slip diagonal lines occur on the steel tube outer surface and the concrete-filled steel tube flanges of all specimens exhibit shear failure. Specimen load-displacement curves can be broadly divided into elastic deformation, elastic-plastic deformation, and load descending and residual deformation stages. The specimen axial compression bearing capacity and ductility increase with increasing ξ, and the axial compression bearing capacity increases gradually with increasing fcu, whereas the ductility decreases. The ductility significantly improves with increasing t2, whereas the axial compression bearing capacity increases slightly. The axial compression bearing capacity decreases gradually with increasing λs, whereas the ductility increases. An analytical expression for the STHCC short column axial compression bearing capacity is established by introducing a correction function ( w ), which has good agreement with experimental results. Finally, several design guidelines are suggested, which can provide a foundation for the popularization and application of this kind of novel composite column in practical engineering projects.


2018 ◽  
Vol 792 ◽  
pp. 160-165 ◽  
Author(s):  
Anatoly L. Krishan ◽  
Maria A. Astafyeva ◽  
Elvira P. Chernyshova

This work is dedicated to an experimental research of strength and resistance characteristics of axially loaded concrete filled steel tube elements of self-stressing concrete, including high-performance concrete. Labcrete specimens of circular section 112 mm in diameter and 1000 mm in length were used in experiments. The research shows that the use of self-stressing concrete increased the strength of the specimens by approximately 10%, and enhanced elastic behavior limit by 20-33%. In the course of testing self-stressing concrete specimens, registered longitudinal deformations were within 0.52-0.75%. Analysis of the obtained results indicates a significantly greater case effect in the pre-stressed specimens. This effect is somewhat less pronounced in high-performance concrete specimens, yet still prominent.


2009 ◽  
Vol 405-406 ◽  
pp. 50-54
Author(s):  
Yi Bo Yang ◽  
Song Liang ◽  
Hai Hong Mo ◽  
You Wen Chen ◽  
Jun Sheng Chen ◽  
...  

Guangzhou Xita Project uses a special exterior frame which consists of huge inclining concrete-filled columns. To ensure the engineering quality and select the suitable concrete-filled steel tube column structure, two concrete-filled steel tube column structure experiments have been carried out. To ensure the quality of the concrete-filled steel tube column structure experiment, the C100, C90 and C70 high performance concrete experimental research have been done specially, and the result of the experimental researches has been used in concrete-filled steel tube column structure sample successfully. The raw materials, mixture proportions and performance of the high performance concrete were discussed in this paper.


Sign in / Sign up

Export Citation Format

Share Document