scholarly journals Experimental Research on a Kind of High-pressure Hot Gas Servo Valve Based on PWM Principle

Author(s):  
Zhong Yang ◽  
Xin Zhang
Author(s):  
J. Michael Owen ◽  
Hui Tang ◽  
Gary D. Lock

Ingress is the leakage of hot mainstream gas through the rim-seal clearance into the wheel-space between the rotating turbine disk (the rotor) and the adjacent stationary casing (the stator). The high-pressure rotor is purged by a radial outflow of air from the high-pressure compressor, and this cooling air is also used to reduce the ingress. The engine designer needs to predict the stator and rotor temperatures as a function of cooling-flow rate. The sealing effectiveness determines how much air is needed to reduce or prevent ingress; although there are numerous theoretical and experimental papers on the effectiveness of different seal geometries, there are few papers on the effect of ingress on the temperature of the rotating disk. This is an unsolved problem of great practical importance: under high stress, a small increase in metal temperature can significantly reduce operating life. In this paper, conservation equations and control volumes are used to develop theoretical equations for the exchange of mass, concentration and enthalpy in an adiabatic rotor–stator system when ingress occurs. It is assumed that there are boundary layers on the rotor and stator, separated by an inviscid rotating core, and the fluid entrained from the core into the boundary layer on the rotor is recirculated into that on the stator. The superposed cooling flow protects the rotor surface from the adverse effects of hot-gas ingress, which increases the temperature of the fluid entrained into the rotor boundary layer. A theoretical model has been developed to predict the relationship between the sealing effectiveness on the stator and the adiabatic effectiveness on the rotor, including the effects of both ingress and frictional heating. The model involves the use of a nondimensional buffer parameter, Ψ, which is related to the relative amount of fluid entrained into the rotor boundary layer. The analysis shows that the cooling flow acts as a buffer, which attenuates the effect of hot gas ingress on the rotor, but frictional heating reduces the buffer effect. The theoretical effectiveness curves are in good agreement with experimental data obtained from a rotor–stator heat-transfer rig, and the results confirm that the buffer effect increases as the sealing effectiveness of the rim seals decreases. The analysis quantifies the increase in the adiabatic rotor temperature due to direct frictional heating, which is separate from the increase due to the combined effects of the ingress and the indirect frictional heating of the entrained fluid. These combined effects are reduced as Ψ increases, and Ψ = 1 at a critical flow rate above which there is no entrained fluid and consequently no indirect heating of the rotor. The model also challenges the conventional physical interpretation of ingress as, in general, not all the hot gas that enters the rim-seal clearance can penetrate into the wheel-space. The ingress manifests itself through a mixing of enthalpy, which can be exchanged even if no ingested fluid enters the wheel-space.


Author(s):  
Neil Goldstein ◽  
Carlos A. Arana ◽  
Fritz Bien ◽  
Jamine Lee ◽  
John Gruninger ◽  
...  

The feasibility of an innovative minimally intrusive sensor for monitoring the hot gas stream at the turbine inlet in high performance aircraft gas turbine engines was demonstrated. The sensor uses passive fiber-optical probes and a remote readout device to collect and analyze the spatially resolved spectral signature of the hot gas in the combustor/turbine flowpaths. Advanced information processing techniques are used to extract the average temperature, temperature pattern factor, and chemical composition on a sub-second time scale. Temperatures and flame composition were measured in a variety of combustion systems including a high pressure, high temperature combustion cell. Algorithms for real-time temperature measurements were developed and demonstrated. This approach should provide a real-time temperature profile, temperature pattern factor, and chemical species sensing capability for multi-point monitoring of high temperature and high pressure flow at the combustor exit with application as an engine development diagnostic tool, and ultimately, as a real-time active control component for high performance gas turbines.


2019 ◽  
Vol 103 ◽  
pp. 329-336
Author(s):  
Yue Li ◽  
Quan Dong ◽  
Xiaoyan Wang ◽  
Enzhe Song ◽  
Liyun Fan ◽  
...  

1994 ◽  
Vol 12 (4) ◽  
pp. 869-887 ◽  
Author(s):  
S. Hulkkonen ◽  
O. Heinonen ◽  
J. Tiihonen ◽  
R. Impola

Author(s):  
V. Zakkay ◽  
E. A. M. Gbordzoe ◽  
K. M. Sellakumar ◽  
C. Q. Lu

Three hot gas clean up units namely, the Screenless Granular Bed Filter (GBF), Ceramic Cross-flow Filter (CXF) and High Temperature, High Pressure Electrostatic Precipitator (ESP) designed for PFBC combined cycle power applications were tested at the New York University (NYU) DOE-PFBC facility located at Westbury, New York using a 780 mm ID pressurized fluidized bed combustor. The combustor was operated up to 10 atma and 870 °C. With the exception of the ESP whose performance was hampered by persistent electrode bushing failure, the particulate capturing efficiencies of the GBF and the CXF were predominantly in the upper 90 % range. The dust loading leaving the filters was consistently lower than the NSPS particulate emission limit. The results also indicate that the filter exit gas stream may meet the gas turbine particulate tolerance limit. None of the three high temperature, high pressure (HTHP) gas clean up units tested emerges as a favorite for use in cleaning PFBC exhaust stream because, each has mechanical design as well as operational flaws which could be corrected. The Cross-flow filter suffered from filter element cracking or delamination or gasket failure during its short test program. The backpulse cleaning system also needs to be optimized. The GBF is susceptible to media bubbling and granule flow problems through its lower seal leg. The Electrostatic Precipitator tested at NYU failed because its electrode bushings cracked due to overheating and could not hold their designed voltage. Further HTHP filter testing at the sub-pilot plant scale is necessary to optimize filter design and develop effective operational procedures for the hot gas clean up systems that will make them viable for commercial PFBC application.


Author(s):  
Joseph T. Hamrick

The paper discusses the problems encountered in providing a high-pressure hot-gas source to the turbine of an aircraft engine starter, the methods of solving these problems, and the design procedures followed in arriving at a solid-propellant cartridge which functioned in all the environments encountered in both storage and operation. Development techniques and results of experimental investigations are presented.