Solid-phase radioimmunoassay for morphine, with use of an affinity-purified morphine antibody.

1978 ◽  
Vol 24 (2) ◽  
pp. 339-342 ◽  
Author(s):  
M Steiner ◽  
J L Spratt

Abstract Morphine antibody purified by affinity chromatography was used to develop a solid-phase radioimmunoassay for morphine in polystyrene tubes. The tubes are coated with an appropriate concentration of the purified antibody, rinsed three times with buffered saline, and stored at -15 degrees C. Using tritiated dihydromorphine, we determined competitive morphine binding by difference when the radioactivity in the assay supernates was measured after incubation (1 h, 37 degrees C). Five standard curves, with use of serum equivalents of morphine ranging from 0 to 6 mug/liter, were linear and had a mean correlation coefficient of 0.98. Uncer conditions of the assay, levorphanol was comparable to morphine in its inhibitory effect on binding of labeled dihydromorphine, whereas dextrorphan was essentially inactive. Morphine-3-glucuronide, a major metabolite, is 55-fold less inhibitory in terms of its capacity to displace the radiolabel. We believe that the sensitivity of the technique, coupled with the simplicity of nonseparatory sampling, renders the system suitable for rapid determination of morphine and related compounds in biological fluids.

1978 ◽  
Vol 8 (2) ◽  
pp. 134-141
Author(s):  
B Ziola ◽  
O Meurman ◽  
M T Matikainen ◽  
A Salmi ◽  
J L Kalliomäki

A solid-phase radioimmunoassay for the rapid determination of human immunoglobulin M (IgM) rheumatoid factor (RF) has been developed. Preparation of the solid phase for the assay involved the formation of complexes between respiratory syncytial virus-specific human IgG antibodies and virus antigen on the surface of polystyrene balls. Binding of serum RF to IgG in the immune complex was subsequently detected by 125I-labeled mu-chain-specific antibodies to human IgM. The amount of radioactive indicator antibody bound was converted to units of RF by comparison to the standard curve for an RF reference-serum pool. This assay should prove useful in studies of the physiological role of RF, since it can effectively measure low levels of circulating RF.


2002 ◽  
Vol 35 (2) ◽  
pp. 269-282 ◽  
Author(s):  
A. Ruiz Medina ◽  
M. C. Cano García ◽  
A. Molina Díaz

2021 ◽  
Author(s):  
Long Li ◽  
Kehan Xu ◽  
Zuohua Huang ◽  
Xinxin Xu ◽  
Jibran Iqbal ◽  
...  

A new in-syringe membrane SPE and solid-phase visible spectra method was proposed for the rapid extraction and visible spectra determination of trace Cu2+. The chelation and membrane SPE can be...


Sign in / Sign up

Export Citation Format

Share Document