Liquid-chromatographic profiling of endogenous fluorescent substances in sera and urine of uremic and normal subjects.

1983 ◽  
Vol 29 (4) ◽  
pp. 675-677 ◽  
Author(s):  
H Mabuchi ◽  
H Nakahashi

Abstract Endogenous fluorescent substances increase in serum during uremia. We have used "high-performance" liquid chromatography to profile these fluorescent substances in both uremic and normal body fluids. The fluorescence excitation and emission maxima we used were 322 and 415 nm, respectively. Of the numerous fluorescent substances found in uremic body fluids and in normal urine, some were also detectable in normal serum, but at relatively weak fluorescence intensities.

1993 ◽  
Vol 264 (5) ◽  
pp. L490-L495 ◽  
Author(s):  
A. B. Cohen ◽  
M. D. Stevens ◽  
E. J. Miller ◽  
M. A. Atkinson ◽  
G. Mullenbach ◽  
...  

We carried out studies to determine whether the neutrophil-activation peptide-2 (NAP-2) plays a role in the recruitment and/or degranulation of neutrophils into the lungs of patients with the adult respiratory distress syndrome (ARDS) or congestive heart failure (CHF). NAP-2 precursors plus NAP-2 (beta-thromboglobulin-like antigen) were measured in lung fluids and plasmas with a radioimmunoassay, and NAP-2 was separated from its precursors by high-performance liquid chromatography. Pulmonary edema fluids (PEFs) from patients with CHF contained higher concentrations of the beta-thromboglobulin-like antigen than PEFs from patients with ARDS, and bronchoalveolar lavage fluids (BALs) from patients with ARDS contained higher concentrations of beta-thromboglobulin-like antigen than BALs from normal subjects. beta-Thromboglobulin-like antigen concentration was 4.1-fold greater in PEFs from patients with CHF than in their plasmas. Chemotactically active NAP-2 was also demonstrated in PEFs but not in plasmas from patients with CHF and ARDS. These data suggest that significant platelet degranulation occurred into the lungs of the patients with CHF and that NAP-2 and other platelet constituents may contribute to fluid formation in patients with CHF.


1975 ◽  
Vol 145 (3) ◽  
pp. 517-526 ◽  
Author(s):  
F B Jungalwala ◽  
R J Turel ◽  
J E Evans ◽  
R H McCluer

A highly sensitive method for the separation and quantitative measurement of phospholipids containing primary amino groups, such as phosphatidylethanolamine, phosphatidylserine and lysophosphatidylethanolamine, is described. The method involves a simple and quantitative derivative formation of the phospholipids containing amino groups to their u.v.-absorbing biphenylcarbonyl derivatives. These have molar extinction coefficients of about 23,000 at 268nm. The phospholipid derivatives are then separated and non-destructively determined by high-performance liquid chromatography. The amino phospholipids containing vinyl ether bonds (plasmalogens) can be determined separately from the diacyl- and alkylacyl-amino phospholipids. The lower limit of detection by high-performance liquid-chromatographic analysis of the phospholipid derivatives is about 10-13pmol or 0.3-0.4ng of phospholipid P. The quantitative range of derivative formation and analysis by high-performance liquid chromatography of the phospholipids containing amino groups was shown to be 10-500nmol. The method was shown to be applicable to the analysis of phospholipids containing amino groups in tissue samples.


1980 ◽  
Vol 26 (10) ◽  
pp. 1499-1503 ◽  
Author(s):  
M D Ullman ◽  
R E Pyeritz ◽  
H W Moser ◽  
D A Wenger ◽  
E H Kolodny

Abstract Quantitative high-performance liquid chromatographic analysis of perbenzoylated sphingolipids has been used to study the correlations of body chemistry to clinical phenomena. Plasma sphingolipids were isolated from 32 Gaucher (β-glucosidase deficiency) and six Fabry (α-galactosidase deficiency) patients by solvent partition and chromatographic separation on silicic acid columns. Plasma sphingolipids from a patient undergoing plasma-exchange were separated from interfering lipids with reversed-phase columns. Liquid-chromatographic analysis of sphingolipids provides useful supportive information for diagnoses because affected individuals are shown to possess increased circulating concentrations of the pathognomonic sphingolipid. We also used this technique to monitor sphingolipid concentrations in plasma and urine sediment during plasma exchange of a p atient with Fabry’s disease. Regular plasma exchanges produced and maintained decreased concentrations of sphingolipids in plasma, but near pre-exchange concentrations were observed within days after the therapy was terminated.


1986 ◽  
Vol 32 (1) ◽  
pp. 169-171 ◽  
Author(s):  
D N Buchanan ◽  
J G Thoene

Abstract 3-Hydroxy-3-methylglutaric aciduria was detected in a newborn. The progress of the dietary therapy for the disorder was monitored by dual-column "high-performance" liquid chromatography with a computer-controlled photodiode array spectrophotometric detector. This procedure is a quick way to detect and monitor the progress of 3-hydroxy-3-methylglutaric aciduria.


1986 ◽  
Vol 32 (6) ◽  
pp. 1002-1004 ◽  
Author(s):  
H Hughes ◽  
L Hagen ◽  
R A Sutton

Abstract In this method for 4-hydroxyproline in urine, hydroxyproline is derivatized with 4-chloro-7-nitrobenzofurazan, with subsequent estimation by reversed-phase "high-performance" liquid chromatography. The ranges for excretion of free and total hydroxyproline while the subjects were ingesting unrestricted diets were 2-29 and 122-374 mumol/24 h (n = 21), respectively, with no significant sex-related difference. A comparison with results by colorimetry indicated no significant differences: mean (n = 18) concentrations (mumol/L) of hydroxyproline in urine were 180 (SD 149) by the present method, 163 (SD 166) by colorimetry. For protein hydrolysate the respective values were 5.9 (SD 2.7) and 6.7 (SD 2.9).


2020 ◽  
Vol 12 (44) ◽  
pp. 5380-5391
Author(s):  
Yanawath Santaladchaiyakit ◽  
Supalax Srijaranai

A simple and rapid preconcentration method using dissolvable Mg/Al LDHs and SDS has been demonstrated for high performance liquid chromatographic analysis of benzoylurea insecticides in water and honey samples.


Sign in / Sign up

Export Citation Format

Share Document