Thinking about the future – data on adolescent patients with a subcutaneous ICD

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Willy ◽  
F Reinke ◽  
B Rath ◽  
N Boegeholz ◽  
J Wolfes ◽  
...  

Abstract Background Implantable cardioverter-defibrillator (ICD) systems are established for the prevention of sudden cardiac death. Long-term data on ICD function in children and adolescents is rare and has suggested higher rates of lead failure as well as oversensing, both leading to inappropriate therapy. The present study displays a long-term single-center follow-up of young patients having received an S-ICD. Methods and results The present study represents a single-center experience of patients younger than 25 years who received an S-ICD (n=49). Follow-up data included regular in-house follow-up as well as unscheduled hospitalisations in our center. Mean age at implantation was 19.2±4.1 years and 33 patients (67.4%) were male. In 21 patients (42.9%) electrical heart disease or idiopathic ventricular fibrillation represented the underlying condition of ICD implantation. 15 patients suffered from HCM (30.6%). Median follow-up duration was 2 years. No patient died during the observation period. Appropriate shocks occurred in 7 patients (14.3%). Inappropriate shock delivery was recorded in 6 patients (12.3%). T-wave oversensing was the main cause for inappropriate shock delivery (5/6 patients), in the other patient myopotentials were the reason for inappropriate therapy. In one patient, operative refixation of the subcutaneous lead was necessary due to hypermobility leading to oversensing. After modification of the sensing vector as well as activation of the SMART pass filter no further oversensing episodes occurred in any patient. Conclusion ICD therapy in children and adolescents is effective for prevention of sudden cardiac death. Every episode was terminated by the first therapy. The rate of appropriate shock as well as inappropriate therapies was quite high compared to typical ICD cohorts. In particular T-wave oversensing seems to be challenging for the S-ICD detection algorithms also in this cohort. Funding Acknowledgement Type of funding source: None

2012 ◽  
pp. 74-83
Author(s):  
Anh Tien Hoang ◽  
Nhat Quang Nguyen

Background: Decades of research now link TWA with inducible and spontaneous clinical ventricular arrhythmias. This bench-to-bedside foundation makes TWA, NT-ProBNP a very plausible index of susceptibility to ventricular arrythmia, and motivates the need to define optimal combination of TWA and NT-ProBNP in predicting ventricular arrythmia in myocardial infarction patients. We research this study with 2 targets: 1. To evaluate the role of TWA in predicting sudden cardiac death in myocardial infarction patients. 2. To evaluate the role of NT-ProBNP in predicting sudden cardiac death in myocardial infarction patients 3. Evaluate the role of the combined NT-ProBNP and TWA in predicting sudden cardiac death in myocardial infarction patients. Methods: Prospective study with follow up the mortality in 2 years: 71 chronic myocardial infarction patients admitted to hospital from 5/2009 to 5/20011 and 50 healthy person was done treadmill test to caculate TWA; ECG, echocardiography, NT-ProBNP. Results: Cut-off point of NT-ProBNP in predicting sudden cardiac death is 3168 pg/ml; AUC = 0,86 (95% CI: 0,72 - 0,91); Cut-off point of TWA in predicting sudden cardiac death is 107 µV; AUC = 0,81 (95% CI: 0,69 - 0,87); NT-ProBNP can predict sudden cardiac death with OR= 7,26 (p<0,01); TWA can predict sudden cardiac death with OR= 8,45 (p<0,01). The combined NT-ProBNP and TWA in predicting ventricular arrythmia in heart failure patients: OR= 17,91 (p<0,001). Conclusions: The combined NT-ProBNP and TWA have the best predict value of sudden cardiac death in myocardial infarction patients, compare to NT-ProBNP or TWA alone


2008 ◽  
Vol 14 (7) ◽  
pp. S140-S141
Author(s):  
Kenji Ando ◽  
Yoshimitsu Soga ◽  
Masahiko Goya ◽  
Shinichi Shirai ◽  
Shinya Nagayama ◽  
...  

2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Erick A. Perez-Alday ◽  
Aron Bender ◽  
David German ◽  
Srini V. Mukundan ◽  
Christopher Hamilton ◽  
...  

Abstract Background The risk of sudden cardiac death (SCD) is known to be dynamic. However, the accuracy of a dynamic SCD prediction is unknown. We aimed to measure the dynamic predictive accuracy of ECG biomarkers of SCD and competing non-sudden cardiac death (non-SCD). Methods Atherosclerosis Risk In Community study participants with analyzable ECGs in sinus rhythm were included (n = 15,716; 55% female, 73% white, age 54.2 ± 5.8 y). ECGs of 5 follow-up visits were analyzed. Global electrical heterogeneity and traditional ECG metrics (heart rate, QRS, QTc) were measured. Adjudicated SCD was the primary outcome; non-SCD was the competing outcome. Time-dependent area under the receiver operating characteristic curve (ROC(t) AUC) analysis was performed to assess the prediction accuracy of a continuous biomarker in a period of 3,6,9 months, and 1,2,3,5,10, and 15 years using a survival analysis framework. Reclassification improvement as compared to clinical risk factors (age, sex, race, diabetes, hypertension, coronary heart disease, stroke) was measured. Results Over a median 24.4 y follow-up, there were 577 SCDs (incidence 1.76 (95%CI 1.63–1.91)/1000 person-years), and 829 non-SCDs [2.55 (95%CI 2.37–2.71)]. No ECG biomarkers predicted SCD within 3 months after ECG recording. Within 6 months, spatial ventricular gradient (SVG) elevation predicted SCD (AUC 0.706; 95%CI 0.526–0.886), but not a non-SCD (AUC 0.527; 95%CI 0.303–0.75). SVG elevation more accurately predicted SCD if the ECG was recorded 6 months before SCD (AUC 0.706; 95%CI 0.526–0.886) than 2 years before SCD (AUC 0.608; 95%CI 0.515–0.701). Within the first 3 months after ECG recording, only SVG azimuth improved reclassification of the risk beyond clinical risk factors: 18% of SCD events were reclassified from low or intermediate risk to a high-risk category. QRS-T angle was the strongest long-term predictor of SCD (AUC 0.710; 95%CI 0.668–0.753 for ECG recorded within 10 years before SCD). Conclusion Short-term and long-term predictive accuracy of ECG biomarkers of SCD differed, reflecting differences in transient vs. persistent SCD substrates. The dynamic predictive accuracy of ECG biomarkers should be considered for competing SCD risk scores. The distinction between markers predicting short-term and long-term events may represent the difference between markers heralding SCD (triggers or transient substrates) versus markers identifying persistent substrate.


Heart Rhythm ◽  
2012 ◽  
Vol 9 (9) ◽  
pp. 1579 ◽  
Author(s):  
Gust Bardy ◽  
Kerry Lee ◽  
Daniel Mark ◽  
Jeanne Poole ◽  
Daniel Fishbein ◽  
...  

2010 ◽  
Vol 139 (5) ◽  
pp. 1306-1315 ◽  
Author(s):  
Nilto C. De Oliveira ◽  
Satoru Osaki ◽  
James D. Maloney ◽  
Keith C. Meyer ◽  
Takushi Kohmoto ◽  
...  

1985 ◽  
Vol 110 (6) ◽  
pp. 1139-1145 ◽  
Author(s):  
Donald D. Tresch ◽  
Jule N. Wetherbee ◽  
Ronald Siegel ◽  
Paul J. Troup ◽  
Michael H. Keelan ◽  
...  

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
R Alves Pinto ◽  
T Proenca ◽  
M Martins Carvalho ◽  
PD Grilo ◽  
CX Resende ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background  Sudden cardiac death (SCD) is an uncommon event in the absence of structural heart disease. However, ventricular fibrillation (VF) may occur in patients with unknown cardiac disease and a comprehensive work-up is needed to further improve diagnostic. Still, a significant and heterogenous group of patients remains labelled of Idiopathic VF and limited data is available regarding their natural history. Purpose The aim of this study was to evaluate the clinical outcomes of survivors of an aborted sudden cardiac death due to idiopathic VF or pulseless ventricular tachycardia (VT) and to assess possible predictors of recurrence. Methods  Patients who survived an idiopathic VF or pulseless VT between 2005 and 2019 referred to a cardiac defibrillator (ICD) implantation were included. Patients were followed for 1 to 15 years (median follow-up of 7 years). Clinical and device data were collected. Results A population of 29 patients, 59% male, with a median age of 50 years (age ranging from 18 to 76) at the time of the aborted SCD was studied. All patients implanted an ICD (69% single chamber, 24% dual chamber and 3% subcutaneous) at the index hospitalization. The initial rhythm was VF in 76% and pulseless VT in 24%. In relation to the context of the arrhythmic event, 48.3% occurred during daily life activities, 13.8% after an emotional stress, 6.9% during efforts and a similar percentage occurred either in rest or asleep. Of note, 12.5% of patients had previous history of syncope. Normal ECG was present in 83% of patients. Family history of SCD was present in 12% of the cases. As for the cardiovascular risk factors, 61.5% had hypertension, 19% dyslipidemia, 17% diabetes, 31% were smokers or previous smokers. Paroxysmal atrial fibrillation was present in 15% of patients. To exclude possible causes of VF, all patients were submitted to coronary angiogram and echocardiogram, 64% to genetic testing, 68% to cardiac magnetic resonance, 20% to electrophysiologic study, 12% to pharmacological provocative test and 4% were submitted to endomyocardial biopsy. At follow-up, an etiological diagnosis was established in 31% of patients: 3 events were attributed to coronary vasospasm, 3 to short coupled polymorphic VT, 1 patient had long QT syndrome, 1 had Brugada syndrome and in 1 patient an ANK2 mutation was identified. As for the clinical outcomes, 8% patients died (from non-arrhythmic causes), 31% patients received appropriate therapies and 19% had unappropriated shocks (of those 60% for sinus tachycardia and 40% for supraventricular tachycardia). Conclusion Etiologic diagnosis and prediction of recurrence of arrhythmic events in patients with idiopathic VF is challenging, even with a long-term follow-up and more sophisticated diagnostic evaluation.  Idiopathic VF is a rare but serious condition with recurrence in about one third of patients. Although not free of complications, ICD remains the gold standard of treatment.


2021 ◽  
Author(s):  
Soheila Jalali ◽  
Mojgan Karbakhsh ◽  
Mehdi Momeni ◽  
Marzieh Taheri ◽  
Saeid Amini ◽  
...  

Abstract BackgroundEvidence concerning impact of long-term exposure to fine Particulate Matter<2.5 mm (PM2.5) on Cardio-Vascular Diseases (CVDs) for those people subject to ambient air pollution in developing countries remains quite scant. This study assessed the relationship of 15-year PM2.5 exposure and cardiovascular incidence and mortality rate in Isfahan province, Iran. MethodsThe cohort comprised 3081 participants over 35 years old and free of CVDs. They were selected through multi-stage cluster sampling in Isfahan, Iran. PM2.5 exposure for each individual was determined using satellite-based spatiotemporal estimates according to their residential addresses. CVD is defined here as fatal and non-fatal Acute Myocardial Infarctions (AMI) or stroke and sudden cardiac death. The risk of CVD incidence and mortality was calculated based on average PM2.5 exposure within a study period of 15 years using the Cox proportional hazard model upon adjusting individual risk factors. Annual averages of PM2.5 and the follow-up data of each residential area were combined. ResultsMean three-year PM2·5 exposure was 45.28 µg/m3 in the cohort, ranging from 20.01 to 69.80 µg/m3. The median follow-up was 12.3 years for the whole population. It is notable that 105 cardiovascular and 241 all-cause deaths occurred among 393,786 person months (27 and 61 per 100,000 person months, respectively). In well-adjusted models, 10 μg/m3 increase in PM2.5 corresponded to a 4% increase in the incidence rate of CVDs [0.95 CI=1.022, 1.054] (given p=0.0000014 per 10 µg/m3 increase in PM2.5, the Hazard Ratio (HR) for AMI was 1.073 [0.95 CI=1.029, 1.119] and Ischemic Heart Disease (IHD) was 1.052 [0.95 CI=1.034, 1.071]. No consistent association was found between PM2.5 concentration and CVD deaths (fatal AMI, fatal stroke, and SCD (Sudden Cardiac Death)).ConclusionsThe final results revealed that long-term exposure to ambient PM2.5 with high concentrations correlated with IHD incidence and its major subtypes positively, except for mortality. This finding supports the already found pieces of evidence that PM2.5 contributes to the high susceptibility of people in the eastern Mediterranean region to cardiovascular diseases after 15 years. The outcome accentuates the need for better air quality in many countries.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
S Yodteerug ◽  
P Vathesatogkit ◽  
T Ngamukos ◽  
S Apiyasawat ◽  
P Chandanamattha

Abstract Introduction Early repolarization syndrome is associated with long-term cardiac mortality in Western countries. However, there is no study of this association in Southeast Asian population. Purpose To determine the prevalence of early repolarization and long term risk of cardiac mortality in general Thai population. Methods A total of 2,756 consecutive individuals participating in from the electricity generating authority of Thailand (EGAT) study between 1997 and 2015 were included in this study. Early repolarization pattern (ERP) was defined either as “notching” or “slurring” and was localized into inferior leads, lateral leads, or both. Mortality endpoints included cardiovascular (CV) events and all-cause mortalities. Multivariable Cox-proportional hazard model, adjusted for all major CV risk factors, was used to determine the association between ERP and outcomes. Results Out of 2756 individuals,2,689 had complete data (80% male, mean age 55). ECGs and risk factor profiles were included for analysis. Mean follow up duration was 11.2±6.7 years. There were 444 (16.5%) cases with early repolarization pattern (slurr 54.3%, notching 38.3% and both 7.4%). Inferior leads were the most common localization at 49.8%, followed by lateral leads (35.6%) and both (14.6%). Five-hundred and sixty-six participants were dead during the follow-ups. Of these, 21 were sudden death. ERP was not associated with a greater likelihood of all causes of deaths, 20.5% in ERP and 21.2% in non-ERP (hazard ratio,1.04; 95% confidence interval (CI), 0.81 to 1.34; p=0.75). The death rates from coronary heart disease were 7.2% in ERP and 7.6% in non-ERP (HR,1.06; 95% CI, 0.71 to 1.56; p=0.79). The death rates from cardiovascular disease were 11.7% in ERP and 12.0% respectively (HR,1.03; 95% CI, 0.75 to 1.41; p=0.872) and sudden cardiac death was not difference between both groups 1.2 and 1.4% respectively. Conclusion The prevalence of early repolarization in Thai middle-aged population is relatively high. Over a long-term follow-up of 18 years, we did not find any differences in sudden cardiac death or death from any causes between an early repolarizationgroup and non-early repolarization group.


Sign in / Sign up

Export Citation Format

Share Document