Volumetric Microsampling of Capillary Blood Spot vs Whole Blood Sampling for Therapeutic Drug Monitoring of Tacrolimus and Cyclosporin A: Accuracy and Patient Satisfaction

2020 ◽  
Vol 5 (3) ◽  
pp. 516-530
Author(s):  
Michael M Mbughuni ◽  
Maria A Stevens ◽  
Loralie J Langman ◽  
Yogish C Kudva ◽  
William Sanchez ◽  
...  

Abstract Background Immunosuppressant therapeutic drug monitoring (TDM) usually requires outpatient travel to hospitals or phlebotomy sites for venous blood collection; however Mitra® Microsampling Device (MSD) sampling could allow self-collection and shipping of samples to a laboratory for analysis. This study examined the feasibility of using volumetric microsampling by MSD for TDM of tacrolimus (TaC) and cyclosporin A (CsA) in transplant patients, along with their feedback on the process. Methods MSD was used to collect TaC and CsA from venous (VB) or capillary (CB) blood. The MSDs were rehydrated, extracted, and analyzed using on-line solid phase extraction coupled to tandem mass spectrometry (SPE-MS/MS). We report an abbreviated method validation of the MSD including: accuracy, precision, linearity, carry-over, and stability using residual venous whole blood (VB) samples. Subsequent clinical validation compared serially collected MSD + CB against VB (200 µL) from transplant patients. Results Accuracy comparing VB vs. MSD+VB showed high clinical concordance (TaC = 89% and CsA = 98%). Inter- and intra-precision was ≤11.5 %CV for TaC and CsA. Samples were stable for up to 7 days at room temperature with an average difference of <10%. Clinical validation with MSD+CB correlated well with VB for CsA (slope = 0.95, r2 = 0.88, n = 47) and TaC (slope = 0.98, r2 = 0.82, n = 49). CB vs. VB gave concordance of 94% for CsA and 79% for TaC. A satisfaction survey showed 82% of patients preferred having the capillary collection option. Conclusion Transplant patients favored having the ability to collect capillary samples at home for TaC/CsA monitoring. Our results demonstrate good concordance between MSD+CB and VB for TaC and CsA TDM, but additional studies are warranted.

2020 ◽  
Vol 58 (5) ◽  
pp. 828-835 ◽  
Author(s):  
Thierry P.I.J.M. Canisius ◽  
J.W.P. Hans Soons ◽  
Pauline Verschuure ◽  
Emmeke A. Wammes-van der Heijden ◽  
Rob P.W. Rouhl ◽  
...  

AbstractBackgroundTherapeutic drug monitoring (TDM) of antiepileptic drugs (AEDs) can serve as a valuable tool in optimising and individualising epilepsy treatment, especially in vulnerable groups such as pregnant women, the elderly and children. Unfortunately, TDM is often performed suboptimally due to limitations in blood collection. Therefore, we investigated volumetric absorptive micro sampling (VAMS) – a new home-sampling technique. We aimed to evaluate VAMS to determine and quantify the different AEDs and concentrations of 16 different AEDs in whole blood collected by VAMS.MethodsPatient blood samples (n = 138) were collected via venepunctures at the Academic Centre for Epileptology Kempenhaeghe. AED concentrations were determined, and these concentrations were used to compare the VAMS method (whole blood) with the conventional method (serum). In addition, the recovery was examined as well as the impact of haematocrit. Finally, AED-spiked blood was used to test the stability of the AEDs inside the micro-sampler devices over a period of time and whether temperature had an effect on the stability.ResultsVAMS allows for an accurate detection of 16 different AEDs within 2 days after sampling. Deviation in recovery was less than 10% and high correlations were found between VAMS and conventional sampling. Moreover, haematocrit does not have an effect with values between 0.3 and 0.5 (L/L). Finally, although storage temperature of VAMS does affect some AEDs, most are unaffected.ConclusionsVAMS enables an accurate detection of a wide variety of AEDs within 2 days after sampling.


2001 ◽  
Vol 5 (2) ◽  
pp. 119-124 ◽  
Author(s):  
Gordon D. MacFarlane ◽  
Raman Venkataramanan ◽  
Sue V. McDiarmid ◽  
John D. Pirsch ◽  
Daniel G. Scheller ◽  
...  

1996 ◽  
Vol 42 (12) ◽  
pp. 1943-1948 ◽  
Author(s):  
K L Napoli ◽  
B D Kahan

Abstract During phase I/II clinical trials of sirolimus (rapamycin; SRL), therapeutic drug monitoring was performed with a multistep liquid-liquid extraction of 1-mL aliquots of whole blood followed by reversed-phase HPLC with ultraviolet detection. Blood was sampled according to a standardized protocol and clinical status. SRL concentrations were interpolated from calibration curves with a linear range of 0-50 micrograms/L and 1 microgram/L lower limit of quantification. Quality control was monitored over 68 consecutive analytical runs by using frozen aliquots of SRL-supplemented pooled whole blood at 4, 12, and 32 micrograms/L. These samples showed mean concentrations of 3.7 +/- 0.6, 10.9 +/- 1.1, and 29.6 +/- 2.6 micrograms/L, respectively. This method for therapeutic drug monitoring of SRL permits one full-time technician to analyze 100 clinical specimens per week with a 24-h turnaround time. With this method, a strong linear relation (r2 = 0.946, Sy/x = 0.41, n = 115) between the average SRL concentration over a 24-h period and the SRL concentration at the 24th h was revealed.


1994 ◽  
Vol 40 (12) ◽  
pp. 2247-2253 ◽  
Author(s):  
M Winkler ◽  
B Ringe ◽  
J Baumann ◽  
M Loss ◽  
K Wonigeit ◽  
...  

Abstract By retrospective analysis of 13,000 blood samples obtained from 248 patients receiving FK 506 therapy, we compared the suitability of plasma with that of whole blood as the matrix for therapeutic drug monitoring of FK 506. The plasma concentrations did not correlate with the concentrations in whole blood (r = 0.56). In contrast to plasma samples (analyzed by enzyme immunoassay), FK 506 was detectable in all whole-blood samples (analyzed by enzyme immunoassay/microparticle enzyme immunoassay). The inter- and intraindividual variations of FK 506 measurements were greater in plasma than in whole blood. Moreover, plasma concentrations correlated only poorly with clinical events. There was a tendency to greater plasma concentrations being measured during episodes of toxicity, but no clear difference was evident between stable course and rejection. In whole-blood specimens, a correlation between reduced or increased FK 506 concentrations and rejection or toxicity, respectively, was observed. The discriminatory power of whole-blood values was greater for the differentiation between toxicity and stable course than between rejection and stable course. We therefore recommend whole blood rather than plasma as the matrix for therapeutic monitoring of FK 506 concentrations.


2013 ◽  
Vol 57 (10) ◽  
pp. 4999-5004 ◽  
Author(s):  
Kim C. M. van der Elst ◽  
Lambert F. R. Span ◽  
Kai van Hateren ◽  
Karin M. Vermeulen ◽  
Tjip S. van der Werf ◽  
...  

ABSTRACTInvasive aspergillosis and candidemia are important causes of morbidity and mortality in immunocompromised and critically ill patients. The triazoles voriconazole, fluconazole, and posaconazole are widely used for the treatment and prophylaxis of these fungal infections. Due to the variability of the pharmacokinetics of the triazoles among and within individual patients, therapeutic drug monitoring is important for optimizing the efficacy and safety of antifungal treatment. A dried blood spot (DBS) analysis was developed and was clinically validated for voriconazole, fluconazole, and posaconazole in 28 patients. Furthermore, a questionnaire was administered to evaluate the patients' opinions of the sampling method. The DBS analytical method showed linearity over the concentration range measured for all triazoles. Results for accuracy and precision were within accepted ranges; samples were stable at room temperature for at least 12 days; and different hematocrit values and blood spot volumes had no significant influence. The ratio of the drug concentration in DBS samples to that in plasma was 1.0 for voriconazole and fluconazole and 0.9 for posaconazole. Sixty percent of the patients preferred DBS analysis as a sampling method; 15% preferred venous blood sampling; and 25% had no preferred method. There was significantly less perception of pain with the DBS sampling method (P= 0.021). In conclusion, DBS analysis is a reliable alternative to venous blood sampling and can be used for therapeutic drug monitoring of voriconazole, fluconazole, and posaconazole. Patients were satisfied with DBS sampling and had less pain than with venous sampling. Most patients preferred DBS sampling to venous blood sampling.


Sign in / Sign up

Export Citation Format

Share Document