scholarly journals Effect of ablation of adenosine induced pulmonary veins dormant conduction after pulmonary vein isolation (PVI) on intermediate term recurrence of atrial fibrillation (AF)

QJM ◽  
2018 ◽  
Vol 111 (suppl_1) ◽  
Author(s):  
S Abdelhafeez Khaled ◽  
M Tawfik Ibrahim ◽  
A Mortada Abdelmoteleb ◽  
H Abdelfattah Badran ◽  
L Elsayed Allam ◽  
...  
EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A P Martin ◽  
M Fowler ◽  
N Lever

Abstract Background Pulmonary vein isolation using cryotherapy is an established treatment for the management of patients with paroxysmal atrial fibrillation. Ablation using the commercially available balloon cryocatheter has been shown to create wide antral pulmonary vein isolation. A novel balloon cryocatheter (BCC) has been designed to maintain uniform pressure and size during ablation, potentially improving contact with the antral anatomy. The extent of ablation created using the novel BCC has not previously been established. Purpose To determine the anatomical extent of pulmonary vein isolation using electroanatomical mapping when performing catheter ablation for paroxysmal atrial fibrillation using the novel BCC. Methods Nine consecutive patients underwent pre-procedure computed tomography angiography of the left atrium to quantify the chamber dimensions. An electroanatomical map was created using the cryoablation system mapping catheter and a high definition mapping system. A bipolar voltage map was obtained following ablation to determine the extent of pulmonary vein isolation ablation. A volumetric technique was used to quantify the extent of vein and posterior wall electrical isolation in addition to traditional techniques for proving entrance and exit block. Results All patients had paroxysmal atrial fibrillation, mean age 56 years, 7 (78%) male. Electrical isolation was achieved for 100% of the pulmonary veins; mean total procedure time was 109 min (+/- 26 SD), and fluoroscopy time 14.9 min (+/- 2.4 SD). The median treatment applications per vein was one (range one - four), and median treatment duration 180 sec (range 180 -240). Left atrial volume 32 mL/m2 (+/- 7 SD), and mean left atrial posterior wall area 22 cm2 (+/- 4 SD). Data was available for quantitative assessment of the extent of ablation for eight patients. No lesions (0 of 32) were ostial in nature. The antral surface area of ablation was not statistically different between the left and right sided pulmonary veins (p 0.63), which were 5.9 (1.6 SD) and 5.4 (2.1 SD) cm2 respectively. In total 50% of the posterior left atrial wall was ablated.  Conclusion Pulmonary vein isolation using a novel BCC provides a wide and antral lesion set. There is significant debulking of the posterior wall of the left atrium. Abstract Figure.


Author(s):  
Filip Casselman ◽  
Ihsan Bakir ◽  
Pedro Brugada ◽  
Peter Geelen ◽  
Francis Wellens ◽  
...  

Objective To evaluate the feasibility and results of isolated endoscopic pulmonary vein isolation for paroxysmal atrial fibrillation using robotics. Methods Between November 2004 and December 2005, 13 patients (38.5% female) underwent robotic pulmonary vein isolation at our institution. Mean age was 46.8 ± 8.4 years and mean preoperative duration of atrial fibrillation was 52.7 ±31.5 months. Indication for surgery was symptomatic drug-refractory paroxysmal atrial fibrillation or recurrence after percutaneous treatment (n = 3). Mean preoperative left atrial dimension was 38.5 ± 6.9 mm. The surgical procedure was performed off-pump as an isolated right chest approach. All procedures were performed using the Flex 10 microwave ablator (Guidant, Indianapolis, IN), which was positioned from the right side through the transverse sinus and around the 4 pulmonary veins. Postoperative drug regimen included sotalol and Coumadin. Mean follow-up was 8.5 ± 3.4 months. Results The procedure was successful in 11 patients. One patient needed conversion to median sternotomy for right pulmonary artery bleeding and a second patient had severe transverse sinus adhesions requiring conversion to a bilateral video-assisted small thoracotomy approach. No other morbidity occurred. Mean procedure time in successful cases was 2.7 ± 0.8 hours (range 1.7 to 4 hours). Permanent sinus rhythm was successfully restored in 10 of 13 patients (76.9% beyond 6 months). Nonsuccessful patients had markedly reduced symptoms and frequency of events. One patient required a left and another a right atrial flutter ablation during follow-up. Conclusions Robotic pulmonary vein isolation is a feasible procedure that has the potential to become a valid option in the treatment of paroxysmal atrial fibrillation.


2020 ◽  
Vol 33 (2) ◽  
pp. 106-114
Author(s):  
Michele Brunelli ◽  
Mark Adrian Sammut

Catheter ablation of long-standing persistent atrial fibrillation is not yet clearly defined with respect to endpoints, and different ablative strategies are offered to patients. Presented here is an approach aiming at biatrial debulking in the form of extensive linear ablation, specifically targeting areas of low-voltage complex fractionated electrograms, in addition to pulmonary vein isolation. Its main advantage is that it is not dependent on operator/system variability, since the strategy of isolating the pulmonary veins, superior vena cava and left atrial posterior wall together with achievement of bidirectional block during linear ablation provides objective endpoints that can consistently be reproduced.


Author(s):  
Sapan Bhuta ◽  
Gustaf Sverin ◽  
Hiro Kawata ◽  
Malek Bashti ◽  
Jessica Hunter ◽  
...  

Background: Previous studies suggest that wide area circumferential pulmonary vein ablation (WACA) is more effective than segmental pulmonary vein ablation (SPVA) for pulmonary vein isolation (PVI) for treatment of atrial fibrillation. Whether this is true in patients (pts) with very short duration paroxysmal atrial fibrillation (PAF) is unknown. Objective: To compare WACA to SPVA in pts with PAF lasting <48 hours. Methods: One hundred pts with PAF <48 hours were randomized to either WACA vs SPVA (45 and 53 pts respectively, with 2 withdrawals), and followed up for 24 months with 14-day ECGs every 6 months. Results: Among 97 pts at an average of 22.1±4.8 months followup, 26 (57.8%) remained free of any atrial arrhythmias after WACA versus 29 (55.86%) after SPVA (p=0.64). Sixteen pts (35.6%) had recurrent PAF after WACA versus 20 pts (38.5%) after SPVA (p=0.79). Seven pts (15.6%) had atrial flutter after WACA versus 5 pts (9.64%) after SPVA (p=0.376) and 1 pt (2.2%) had atrial tachycardia after WACA vs 1 pt (1.9%) after SPVA (p=0.918). Total procedure time was lower for SPVA vs WACA (242.9 vs 271.1 minutes, p= 0.047), and fluoroscopy time similar for WACA vs SPVA (50.8 vs 53.4 minutes, p=0.555). Conclusions: As an initial ablation approach in pts with PAF <48 hours, SPVA was similarly effective to WACA with respect to arrhythmia recurrence, supporting the central role of the pulmonary veins for maintaining AF in these pts. Future therapies using alternative ablation energies may incorporate these insights to reduce risk to gastroesophageal structures.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Shaojie Chen ◽  
Boris Schmidt ◽  
Stefano Bordignon ◽  
Fabrizio Bologna ◽  
K. R. Julian Chun

Abstract Background Cryoballoon ablation is an established procedure for atrial fibrillation (AF). Patients who had previous pulmonary surgery undergoing pulmonary vein isolation (PVI) were seldom reported. Case presentation We describe an AF ablation using the novel short-tip third-generation cryoballoon in a patient with resected pulmonary vein. All pulmonary veins were successfully isolated without complication. The short-tip third-generation cryoballoon shows advantageous profile in PVI for AF patients with previous pulmonary surgery. Conclusions This report indicates that for AF patient who had previous resected PV surgery, the short-tip CB 3 provides an ideal device option for real-time PVI.


2017 ◽  
Vol 4 (45) ◽  
pp. 33-34
Author(s):  
Michał Orczykowski

Second-generation cryoballoon (CB2) - based pulmonary vein isolation (PVI) has demonstrated encouraging clinical results in the treatment of paroxysmal (PAF) and persistent atrial fibrillation (PersAF). Nevertheless, the acute efficacy, safety, and long-term clinical results of CB2-based PVI in patients with a left common pulmonary vein (LCPV) are still a matter of debate. Commented paper by Heeger ChH, et al. analyzes this issue with some practical conclusions.


Sign in / Sign up

Export Citation Format

Share Document