scholarly journals Development of Feed Forward and Conditional Models Based on Rodent Imaging Data to Predict Effects of Nitrogen Mustard on Pulmonary Function

2021 ◽  
Vol 35 (S1) ◽  
Author(s):  
Jaclynn Andres ◽  
Alexa Murray ◽  
Longfei Chao ◽  
Panos Georgopoulos ◽  
Jeffery Laskin ◽  
...  
Author(s):  
C. A. Callender ◽  
Wm. C. Dawson ◽  
J. J. Funk

The geometric structure of pore space in some carbonate rocks can be correlated with petrophysical measurements by quantitatively analyzing binaries generated from SEM images. Reservoirs with similar porosities can have markedly different permeabilities. Image analysis identifies which characteristics of a rock are responsible for the permeability differences. Imaging data can explain unusual fluid flow patterns which, in turn, can improve production simulation models.Analytical SchemeOur sample suite consists of 30 Middle East carbonates having porosities ranging from 21 to 28% and permeabilities from 92 to 2153 md. Engineering tests reveal the lack of a consistent (predictable) relationship between porosity and permeability (Fig. 1). Finely polished thin sections were studied petrographically to determine rock texture. The studied thin sections represent four petrographically distinct carbonate rock types ranging from compacted, poorly-sorted, dolomitized, intraclastic grainstones to well-sorted, foraminiferal,ooid, peloidal grainstones. The samples were analyzed for pore structure by a Tracor Northern 5500 IPP 5B/80 image analyzer and a 80386 microprocessor-based imaging system. Between 30 and 50 SEM-generated backscattered electron images (frames) were collected per thin section. Binaries were created from the gray level that represents the pore space. Calculated values were averaged and the data analyzed to determine which geological pore structure characteristics actually affect permeability.


1973 ◽  
Vol 12 (02) ◽  
pp. 102-107 ◽  
Author(s):  
D. J. Protti ◽  
Nancy Craven ◽  
A. Naimark ◽  
R. M. Cherniack

A previously described comprehensive respiratory information system (CRIS) has been changed to introduce new spirometric tests which are sensitive to minor abnormalities, revise on the basis of additional data the regression equations which define normal values to various parameters of pulmonary function and refine the system’s interpretation scheme. The beneficial effects of transferring the system from a large IBM 360/65 to a small CDC 1700 are presented. An analysis of the costs of processing routine pulmonary function studies reveals that a 40°/o saving is realized when a computer is used in comparison to the use of the usual manual methods.


Sign in / Sign up

Export Citation Format

Share Document