scholarly journals X. Bakerian lecture. - on the mechanical equivalent of heat

1. The determination by Joule, in 1849, of the expenditure of mechanical effect (7 72’69 lbs. falling 1 foot) necessary to raise the temperature of 1 lb. of water, weighed in vacuo, 1° Fahr. between the temperatures of 50° and 60° Fahr. (at Manchester), together with the second, in 1878, 772’55 ft.-lbs., to raise the temperature of 1 lb. (weighed in vacuo) from 60° to 6L° Fahr., at the latitude of Greenwich, established once for all the existence of a physically constant ratio between the work expended in producing heat and the heat produced; while the extreme simplicity of his methods, his marvellous skill as an experimenter, and the complete system of checks he adopted, have led to the universal acceptance of the numbers he obtained as being within the limits he himself assigned (1 foot), of the true ratio of work expended in his experiments in producing heat and the heat produced as measured on the scale of the thermometer on which he spent so much time and care.

1961 ◽  
Author(s):  
Milton H. Hodge ◽  
Morris J. Crawford ◽  
Mary L. Piercy

1987 ◽  
Vol 26 (06) ◽  
pp. 248-252 ◽  
Author(s):  
M. J. van Eenige ◽  
F. C. Visser ◽  
A. J. P. Karreman ◽  
C. M. B. Duwel ◽  
G. Westera ◽  
...  

Optimal fitting of a myocardial time-activity curve is accomplished with a monoexponential plus a constant, resulting in three parameters: amplitude and half-time of the monoexponential and the constant. The aim of this study was to estimate the precision of the calculated parameters. The variability of the parameter values as a function of the acquisition time was studied in 11 patients with cardiac complaints. Of the three parameters the half-time value varied most strongly with the acquisition time. An acquisition time of 80 min was needed to keep the standard deviation of the half-time value within ±10%. To estimate the standard deviation of the half-time value as a function of the parameter values, of the noise content of the time-activity curve and of the acquisition time, a model experiment was used. In most cases the SD decreased by 50% if the acquisition time was increased from 60 to 90 min. A low amplitude/constant ratio and a high half-time value result in a high SD of the half-time value. Tables are presented to estimate the SD in a particular case.


1999 ◽  
Vol 40 (8) ◽  
pp. 145-151 ◽  
Author(s):  
Liliana Borzacconi ◽  
Gisela Ottonello ◽  
Elena Castelló ◽  
Heber Pelaez ◽  
Augusto Gazzola ◽  
...  

The performance of a bench scale upflow sludge bed (USB) denitrifying reactor was evaluated in order to integrate it into a C and N removal system for Sanitary Landfill Leachate. The raw leachate used presented COD and NH4-N average values of 30000 mg/l and 1000 mg/l, respectively. The complete system comprises in addition an UASB reactor and a nitrifying RBC. A portion of the aerobic reactor effluent was recycled into the denitrification stage and some raw leachate was also added as an additional C source. In order to obtain operating parameters the denitrifying reactor was operated alone. Sludge from an aerobic reactor (RBC) treating raw leachate was used as inoculum. Shortly after the start up, good granulation of the sludge bed was observed. Using raw leachate and UASB outlet as carbon sources with COD/NO3-N ratios of 4 and 12, respectively, denitrification efficiencies of about 90% were reached. A sludge yield of 0.16 gVSS/gCODremoved was obtained operating with raw leachate. For the anoxic reactor operating in the complete system, denitrification efficiencies of 90% were also achieved. A nitrogen gas recycle was a successful way to avoid frequently observed sludge bed rising problems.


1975 ◽  
Vol 142 (5) ◽  
pp. 1065-1077 ◽  
Author(s):  
A.P. Osmand ◽  
R.F. Mortensen ◽  
Joan Siegel ◽  
H. Gewurz

Interactions of CRP with various substrates in the presence of human serum have been shown to result in efficient activation of C components C1-C5. We now report the ability of CRP to initiate C-dependent hemolysis. For this purpose CRP was isolated by affinity chromatography using pneumococcal CPS and gel filtration; its purity was established by several criteria. Erythrocytes were coated with CPS (E-CPS) and passively sensitized with CRP. C-dependent lysis of these cells was observed upon the addition of suitably absorbed human serum, and the efficiency of hemolysis compared favorably with that initiated by rabbit IgG anti-CPS antibody. CRP also sensitized E-CPS for lysis by guinea pig C; partial lysis was seen when C4-deficient guinea pig serum was used, suggesting that CRP also shares with antibody the ability of CRP to fully activate the C system and provide further evidence for a role for CRP similar to that of antibody in the initiation and modulation of inflammatory reactions via the complete system.


2005 ◽  
Vol 908 ◽  
Author(s):  
Gary A. Glass ◽  
Bibhudutta Rout ◽  
Alexander D. Dymnikov ◽  
Elia V. Eschenazi ◽  
Richard Greco ◽  
...  

AbstractAn overview of the present state of high energy focused ion beam (HEFIB) system technology, nanoprobe system design and specific ion beam writing applications will be presented. In particular, the combination of P-beam, heavy-ion writing and ion implantation to produce microstructures in resists and silicon will be demonstrated.Heretofore, the development of HEFIB technology worldwide has progressed through a series of developments at independent research facilities, each having relatively narrow and mostly isolated, research purposes. However, a complete, versatile HEFIB nanoprobe system capable of both analysis and modification will require the combination of several component systems, each with specialized technology, and significant advances in the design of a complete system can only be expected from an effort that includes a coordinated development of the component parts.


Sign in / Sign up

Export Citation Format

Share Document