scholarly journals Performance of SARS-CoV-2 rapid antigen test compared with real-time RT-PCR in asymptomatic individuals

Author(s):  
Mónica Peña ◽  
Manuel Ampuero ◽  
Carlos Garcés ◽  
Aldo Gaggero ◽  
Patricia García ◽  
...  

AbstractScreening, testing and contact tracing plays a pivotal role in the control of COVID-19 pandemic. To carry out this strategy it is necessary to increase the testing capacity. Here, we compared a SARS CoV-2 rapid antigen test (RAT) and RT-PCR in 842 asymptomatic individuals from Tarapacá, Chile. We report a sensibility of 69.86%, a specificity of 99.61%, PPV of 94.44% and NPP of 97.22% with Ct values (Ct > 27) that were significantly higher among individuals with false-negative RAT. These results support the fact that RAT might have a significant impact in the identification of asymptomatic carriers in areas that lack well-equipped laboratories to perform SARS-CoV-2 real -time RT-PCR diagnostics or the results take more than 24-48 hours, as well as zones with high traffic of individuals, such as border/customs, airports, interregional bus, train stations or in any mass testing campaign requiring rapid results.

Author(s):  
Mónica Peña ◽  
Manuel Ampuero ◽  
Carlos Garcés ◽  
Aldo Gaggero ◽  
Patricia García ◽  
...  

2021 ◽  
Author(s):  
Yoshihiko Kiyasu ◽  
Yuto Takeuchi ◽  
Yusaku Akashi ◽  
Daisuke Kato ◽  
Miwa Kuwahara ◽  
...  

AbstractIntroductionAntigen testing may help screen for and detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections in asymptomatic individuals. However, limited data regarding the diagnostic performance of antigen tests for this group are available.MethodsWe used clinical samples to prospectively evaluate the analytical and clinical performance of the antigen test QuickNavi™-COVID19 Ag. This study was conducted at a PCR center between October 7, 2020 and January 9, 2021. Two nasopharyngeal samples per patient were obtained with flocked swabs; one was used for the antigen test, and the other for real-time reverse transcription PCR (RT-PCR). The diagnostic performance of the antigen test was compared between asymptomatic and symptomatic patients, and the RT-PCR results were used as a reference.ResultsAmong the 1,934 collected samples, SARS-CoV-2 was detected by real-time RT-PCR in 188 (9.7%); 76 (40.4%) of these samples were from asymptomatic individuals. Over half of the total samples (1,073; 55.5%) were obtained from asymptomatic volunteers. The sensitivity of the antigen test was significantly lower for asymptomatic group than for symptomatic patients (67.1% vs 89.3%, p < 0.001). The specificity was 100% for both groups, and no false positives were observed among all 1,934 samples. The median Ct value for the asymptomatic group was significantly higher than that of the symptomatic group (24 vs 20, p < 0.001).ConclusionsThe QuickNavi™-COVID19 Ag showed a lower sensitivity for asymptomatic group than for symptomatic patients. However, its specificity was consistently high, and no false positives were found in this study.


2020 ◽  
Author(s):  
Monika Malecki ◽  
Jessica Luesebrink ◽  
Andreas Wendel ◽  
Frauke Mattner

In limelight of the ongoing pandemic SARS-CoV-2 testing is critical for the diagnosis of infected patients, contact-tracing and mitigating the transmission. Diagnostic laboratories are expected to provide appropriate testing with maximum accuracy. Real-time reverse transcriptase PCR (RT-PCR) is the diagnostic standard yet many commercial diagnostic kits have become available. However, only a handful of studies have reviewed their performance in clinical settings. The aim of this study was to compare the performance of the overall analytical matrix including the extraction kit (BD MAX, Promega, Qiagen), the PCR instrument (Agilent Mx3005P, BD MAX, Qiagen Rotor-Gene, Roche Cobas z 480) and the RT-PCR assay (Altona Diagnostics, CerTest Biotec, R-Biopharm AG) using predefined samples from proficiency testing organizers. The greatest difference of the Ct values between the matrices was 9 cycles. One borderline sample could not be detected by 3 out of 12 analytical matrices and yielded a false negative result. We therefore conclude that diagnostic laboratories should take the complete analytical matrix in addition to the performance values published by the manufacturer for a respective RT-PCR kit into account. With limited resources laboratories have to validate a wide range of kits to determine appropriate analytical matrices for detecting SARS-CoV-2 reliably. The interpretation of clinical results has to be adapted accordingly.


Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1091
Author(s):  
Ali A. Rabaan ◽  
Raghavendra Tirupathi ◽  
Anupam A Sule ◽  
Jehad Aldali ◽  
Abbas Al Mutair ◽  
...  

Real-time RT-PCR is considered the gold standard confirmatory test for coronavirus disease 2019 (COVID-19). However, many scientists disagree, and it is essential to understand that several factors and variables can cause a false-negative test. In this context, cycle threshold (Ct) values are being utilized to diagnose or predict SARS-CoV-2 infection. This practice has a significant clinical utility as Ct values can be correlated with the viral load. In addition, Ct values have a strong correlation with multiple haematological and biochemical markers. However, it is essential to consider that Ct values might be affected by pre-analytic, analytic, and post-analytical variables such as collection technique, specimen type, sampling time, viral kinetics, transport and storage conditions, nucleic acid extraction, viral RNA load, primer designing, real-time PCR efficiency, and Ct value determination method. Therefore, understanding the interpretation of Ct values and other influential factors could play a crucial role in interpreting viral load and disease severity. In several clinical studies consisting of small or large sample sizes, several discrepancies exist regarding a significant positive correlation between the Ct value and disease severity in COVID-19. In this context, a revised review of the literature has been conducted to fill the knowledge gaps regarding the correlations between Ct values and severity/fatality rates of patients with COVID-19. Various databases such as PubMed, Science Direct, Medline, Scopus, and Google Scholar were searched up to April 2021 by using keywords including “RT-PCR or viral load”, “SARS-CoV-2 and RT-PCR”, “Ct value and viral load”, “Ct value or COVID-19”. Research articles were extracted and selected independently by the authors and included in the present review based on their relevance to the study. The current narrative review explores the correlation of Ct values with mortality, disease progression, severity, and infectivity. We also discuss the factors that can affect these values, such as collection technique, type of swab, sampling method, etc.


2020 ◽  
Vol 7 (11) ◽  
Author(s):  
Gwynngelle A Borillo ◽  
Ron M Kagan ◽  
Russell E Baumann ◽  
Boris M Fainstein ◽  
Lamela Umaru ◽  
...  

Abstract Background Nucleic acid amplification testing is a critical tool for addressing the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. Specimen pooling can increase throughput and conserve testing resources but requires validation to ensure that reduced sensitivity does not increase the false-negative rate. We evaluated the performance of a real-time reverse transcription polymerase chain reaction (RT-PCR) test authorized by the US Food and Drug Administration (FDA) for emergency use for pooled testing of upper respiratory specimens. Methods Positive specimens were selected from 3 prevalence groups, 1%–3%, &gt;3%–6%, and &gt;6%–10%. Positive percent agreement (PPA) was assessed by pooling single-positive specimens with 3 negative specimens; performance was assessed using Passing-Bablok regression. Additionally, we assessed the distributions of RT-PCR cycle threshold (Ct) values for 3091 positive specimens. Results PPA was 100% for the 101 pooled specimens. There was a linear relationship between Ct values for pooled and single-tested specimens (r = 0.96–0.99; slope ≈ 1). The mean pooled Ct shifts at 40 cycles were 2.38 and 1.90, respectively, for the N1 and N3 targets. The median Cts for 3091 positive specimens were 25.9 (N1) and 24.7 (N3). The percentage of positive specimens with Cts between 40 and the shifted Ct was 1.42% (N1) and 0.0% (N3). Conclusions Pooled and individual testing of specimens positive for SARS-CoV-2 demonstrated 100% agreement, which demonstrates the viability of pooled specimens for SARS-COV-2 testing using a dual-target RT-PCR system. Pooled specimen testing can help increase testing capacity for SARS-CoV-2 with a low risk of false-negative results.


2021 ◽  
Vol 15 (10) ◽  
pp. 3356-3358
Author(s):  
Ambreen Fatima ◽  
Nidda Yaseen ◽  
Amna Fareed ◽  
Kashif Ali Samin ◽  
Shumaela Kanwal ◽  
...  

Background and Aim: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) rapid emergence postured significant challenges on the health system in recent years. The early detection of cases is thought to be critical in preventing this pandemic by coronavirus disease (COVID-19), especially important in the obstetrical population due to theirs numerous interactions with another parturient when hospitalized for delivery. Therefore, the present study aimed to assess the COVID antigen test performance in COVID-positive obstetrics patients. Materials and Methods: This cross-sectional study was conducted on 1296 Covid-19 asymptomatic women admitted to the Obstetrics and Gynaecology Department of Muhammad Teaching Hospital & Medical College, Peshawar and Fauji Foundation Hospital, Rawalpindi for the duration of six months from February 2021 to July 2021. Antigen-based test rapid diagnostic test (RDT) was used for screening out COVID-19 positive obstetrics patients or women through nasopharyngeal swabs. Women with negative rapid antigen test results were confirmed with RT-polymers chain reaction test of nucleic acid amplification tests (NAAT). Ethical approval and informed consent were taken from the hospital ethical committee and each individual respectively. All the known positive COVID-19 patients during admission were excluded. SPSS version 24 was used for data analysis. Results: The overall prevalence of rapid antigen-positive tested patients was 13.2% (171/1296). The prevalence of positive tested women through rapid antigen test, Nucleic Acid Amplification Test (NAAT), and RT-PCR were 27 (2.1%), 51 (3.9%), and 93 (7.2%) respectively. Of the total 1296 rapid antigen tests, 27 were positive, and the false-negative confirmed positive by NAAT was 144.Thus the sensitivity of the rapid antigen test was 15.8% and the negative predictive value was 93.7%. Of the total 298 Nucleic Acid Amplification Tested had sensitivity and negative predictive value of 89.6% and 99.06% respectively. RT-PCR was carried out on 972 patients, positive diagnosed cases were 36 while 15 were initially negative and were positive with the test was repeated. The sensitivity and negative predictive value was 71.45% and 95.8% respectively. Conclusion: Our study found that Ag-RDT plays a significant role in SARS-CoV-2 early detection in infected individuals, with high specificity and sensitivity to disease infectious stage, whether symptomatic or asymptomatic, and can be used as a decision supported tool. Early detection of COVID-19 status in women admitted for delivery could benefit neonatal protection care. Keywords: Covid-19; Rapid antigen test; RT-PCR test


2020 ◽  
Vol 13 (1) ◽  
Author(s):  
Viktor Szatmári ◽  
Martin Willem van Leeuwen ◽  
Christine Jantine Piek ◽  
Luigi Venco

Abstract Background Dirofilaria immitis is responsible for heartworm disease in dogs in endemic areas worldwide. Screening for this infection is done by blood tests. Antigen testing is the most sensitive method to detect an infection with adult (female) worms. Microscopic examination of a blood smear or Knott’s test can be used to detect circulating microfilariae, the infective larvae. To increase the sensitivity of the antigen test by decreasing the false negative test results, heating of the blood sample has been recommended in recent guidelines. Heating is believed to remove blocking immune-complexes. Circulating microfilariae are not specific findings for heartworm infection, as other nematodes (among others, Acanthocheilonema dracunculoides) can also result in microfilaremia. Although the type of microfilariae cannot be determined by microscopy alone, real-time PCR can reliably identify the infecting nematode species. Correct identification of the parasite is of major importance, as an infection with D. immitis requires antiparasitic therapy, whereas A. dracunculoides is thought to be a clinically irrelevant coincidental finding. The present case report describes a microfilaremic dog where the initial antigen test for D. immitis turned positive after heat treatment, whereas real-time PCR revealed that the microfilariae were A. dracunculoides (syn. Dipetalonema dracunculoides). Results A circa 5-year old, asymptomatic Spanish mastiff dog was referred for heartworm therapy because microfilariae were found via a screening blood test. The dog was recently imported to the Netherlands from Spain, where it had been a stray dog. Antigen tests on a plasma sample for D. immitis were performed with three different test kits, which all turned out to be negative. However, heat treatment of two of these samples were carried out and both of them led to a positive antigen test result. Real-time PCR showed that the circulating microfilariae belonged to A. dracunculoides species. Three administrations of moxidectin spot-on at monthly intervals resulted in a negative antigen and a negative Knott’s tests one month after the last treatment. Conclusions We conclude that heat treatment of initially negative blood samples for D. immitis could lead to false positive antigen test results if the dog is infected with A. dracunculoides.


2017 ◽  
Vol 83 (6) ◽  
Author(s):  
Chao Liao ◽  
Yong Zhao ◽  
Luxin Wang

ABSTRACT This study developed RNA-based predictive models describing the survival of Vibrio parahaemolyticus in Eastern oysters (Crassostrea virginica) during storage at 0, 4, and 10°C. Postharvested oysters were inoculated with a cocktail of five V. parahaemolyticus strains and were then stored at 0, 4, and 10°C for 21 or 11 days. A real-time reverse transcription-PCR (RT-PCR) assay targeting expression of the tlh gene was used to evaluate the number of surviving V. parahaemolyticus cells, which was then used to establish primary molecular models (MMs). Before construction of the MMs, consistent expression levels of the tlh gene at 0, 4, and 10°C were confirmed, and this gene was used to monitor the survival of the total V. parahaemolyticus cells. In addition, the tdh and trh genes were used for monitoring the survival of virulent V. parahaemolyticus. Traditional models (TMs) were built based on data collected using a plate counting method. From the MMs, V. parahaemolyticus populations had decreased 0.493, 0.362, and 0.238 log10 CFU/g by the end of storage at 0, 4, and 10°C, respectively. Rates of reduction of V. parahaemolyticus shown in the TMs were 2.109, 1.579, and 0.894 log10 CFU/g for storage at 0, 4, and 10°C, respectively. Bacterial inactivation rates (IRs) estimated with the TMs (−0.245, −0.152, and −0.121 log10 CFU/day, respectively) were higher than those estimated with the MMs (−0.134, −0.0887, and −0.0732 log10 CFU/day, respectively) for storage at 0, 4, and 10°C. Higher viable V. parahaemolyticus numbers were predicted using the MMs than using the TMs. On the basis of this study, RNA-based predictive MMs are the more accurate and reliable models and can prevent false-negative results compared to TMs. IMPORTANCE One important method for validating postharvest techniques and for monitoring the behavior of V. parahaemolyticus is to establish predictive models. Unfortunately, previous predictive models established based on plate counting methods or on DNA-based PCR can underestimate or overestimate the number of surviving cells. This study developed and validated RNA-based molecular predictive models to describe the survival of V. parahaemolyticus in oysters during low-temperature storage (0, 4, and 10°C). The RNA-based predictive models show the advantage of being able to count all of the culturable, nonculturable, and stressed cells. By using primers targeting the tlh gene and pathogenesis-associated genes (tdh and trh), real-time RT-PCR can evaluate the total surviving V. parahaemolyticus population as well as differentiate the pathogenic ones from the total population. Reliable and accurate predictive models are very important for conducting risk assessment and management of pathogens in food.


2021 ◽  
Vol 9 (1) ◽  
pp. 44-45
Author(s):  
Dinesh Kumar

Recently, an argument was put forth because a symptomatic and positive patient for CoVID-19 turned tested negative after 7 days, so discharged from the hospital. Both at the time of admission and discharge real-time reverse transcriptase Polymerase Chain Reaction (RT-PCR) was done for testing of CoVID-19. Immediately, patient again developed respiratory symptoms and was admitted to hospital again. Amidst of current CoVID-19 pandemic, a question was asked “What is the specificity of the Real Time-Polymerase Chain Reaction (RT-PCR) test for COVID-19?” with an assumption that what if at the time of discharge the disease is present in patient but test turned out to be negative? In response to that a counter statement was posed that “It is the sensitivity that should be asked rather than specificity”. It was based on the implication of primary question that was implying false negative report of the RT-PCR. It means, since patient was discharged with negative result that could be false negative.


2020 ◽  
Vol 9 (3) ◽  
pp. 408-410
Author(s):  
Fatemeh Bahreini ◽  
Rezvan Najafi ◽  
Razieh Amini ◽  
Salman Khazaei ◽  
Saeid Bashirian

As the SARS-CoV-2 (COVID-19) pandemic spreads rapidly, there is need for a diagnostic test with high accuracy to detect infected individuals especially those without symptoms. Real-time polymerase chain reaction (RT-PCR) is a common molecular test for diagnosing SARS-CoV-2. If some factors are not taken into consideration when performing this test, it can have a relatively large number of false negative results. In this article, we discuss important considerations that could lead to false negative test reduction. Key words: • SARS-CoV-2 • COVID-19 • Real time polymerase chain reaction • RT-PCR test • Diagnosis • False negatives • Genetics • Emerging disease   Copyright © 2020 Bahreini et al. Published by Global Health and Education Projects, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0)which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in this journal, is properly cited.