scholarly journals Median based absolute quantification of proteins using Fully Unlabelled Generic Internal Standard

2021 ◽  
Author(s):  
Bharath Kumar Raghuraman ◽  
Aliona Bogdanova ◽  
HongKee Moon ◽  
Ignacy Rzagalinski ◽  
Eric Geertsma ◽  
...  

By reporting molar abundances of proteins, absolute quantification determines their stoichiometry in complexes, pathways or networks and also relates them to abundances of non-protein biomolecules. Typically, absolute quantification relies either on protein- specific isotopically labelled peptide standards or on a semiempirical calibration against the average abundance of peptides chosen from arbitrary selected standard proteins. Here we developed a generic protein standard FUGIS (Fully unlabelled Generic Internal Standard) that requires no isotopic labelling, synthesis of standards or external calibration and is applicable to proteins of any organismal origin. FUGIS is co-digested with analysed proteins and enables their absolute quantification in the same LC-MS/MS run. By using FUGIS, median based absolute quantification (MBAQ) workflow provides similar quantification accuracy compared to isotopically-labelled peptide standards and outperforms methods based on external calibration or selection of best ionized reporter peptides (e.g. Top3 quantification) with a median quantification error below 20%

1979 ◽  
Vol 62 (4) ◽  
pp. 738-741
Author(s):  
Timothy Stevens ◽  
Robert B Grorud

Abstract A high pressure liquid chromatographic (HPLC) assay of amine salt and ester formulations of MCPA has been collaboratively studied. The AOAC 2,4-D HPLC method has been modified for application to MCPA products. The MCPA methodology is identical to that of 2,4-D except in strength of mobile solvent, pH of mobile solvent, heating of ester formulations to 50°C to ensure complete saponification, and the use of glass microfiber filters. The method is specific and separates all known impurities. Examination of chromatograms and percentage results from 8 collaborators indicate that selection of a practical internal standard would improve precision in the procedure and a second collaborative study is recommended.


1992 ◽  
Vol 594 (1-2) ◽  
pp. 45-64 ◽  
Author(s):  
J. Wieling ◽  
P.M.J. Coenegracht ◽  
C.K. Mensink ◽  
J.H.G. Jonkman ◽  
D.A. Doornbos

2010 ◽  
Vol 8 (2) ◽  
pp. 273-277 ◽  
Author(s):  
Kateřina Vítková ◽  
Markéta Pechová ◽  
Jan Petr ◽  
Joanna Znaleziona ◽  
Václav Ranc ◽  
...  

AbstractA method for the fast determination of yohimbine, a potent adrenoreceptor antagonist used for the treatment of sexual dysfunctions, is proposed in this article. MEKC under basic and acidic conditions (sodium borate, pH 9.5 and sodium phosphate, pH 2.5) with SDS was developed. The effect of the experimental parameters, e.g. pH, SDS concentration and injection time, on yohimbine migration was also studied. Both methods were validated in terms of linearity, limits of detection and quantification, accuracy, and precision using caffeine as an internal standard. The application for the determination of yohimbine in hand-made medicaments is also investigated in this study.


1991 ◽  
Vol 1094 (2) ◽  
pp. 147-152 ◽  
Author(s):  
Elke De Bisschop ◽  
Guido Annaert ◽  
Robert Luypaert ◽  
Jean Coremans ◽  
Michel Osteaux

Sign in / Sign up

Export Citation Format

Share Document