Evidence of x-ray absorption-edge shift as a function of luminescence wavelength in porous silicon

2000 ◽  
Vol 62 (15) ◽  
pp. 9911-9914 ◽  
Author(s):  
G. Dalba ◽  
N. Daldosso ◽  
P. Fornasini ◽  
M. Grimaldi ◽  
R. Grisenti ◽  
...  
Author(s):  
R. L. Stears

Because of the nature of the bacterial endospore, little work has been done on analyzing their elemental distribution and composition in the intact, living, hydrated state. The majority of the qualitative analysis entailed intensive disruption and processing of the endospores, which effects their cellular integrity and composition.Absorption edge imaging permits elemental analysis of hydrated, unstained specimens at high resolution. By taking advantage of differential absorption of x-ray photons in regions of varying elemental composition, and using a high brightness, tuneable synchrotron source to obtain monochromatic x-rays, contact x-ray micrographs can be made of unfixed, intact endospores that reveal sites of elemental localization. This study presents new data demonstrating the application of x-ray absorption edge imaging to produce elemental information about nitrogen (N) and calcium (Ca) localization using Bacillus thuringiensis as the test specimen.


2017 ◽  
Vol 88 (5) ◽  
pp. 053501 ◽  
Author(s):  
M. A. Beckwith ◽  
S. Jiang ◽  
A. Schropp ◽  
A. Fernandez-Pañella ◽  
H. G. Rinderknecht ◽  
...  

MRS Advances ◽  
2019 ◽  
Vol 5 (1-2) ◽  
pp. 37-43
Author(s):  
Amber R. Mason ◽  
Stephanie M. Thornber ◽  
Martin C. Stennett ◽  
Laura J. Gardner ◽  
Dirk Lützenkirchen-Hecht ◽  
...  

ABSTRACTA zirconolite glass-ceramic material is a candidate wasteform for immobilisation of chlorine contaminated plutonium residues, in which plutonium and chlorine are partitioned to the zirconolite and aluminosilicate glass phase, respectively. A preliminary investigation of chlorine speciation was undertaken by analysis of Cl K-edge X-ray Absorption Near Edge Spectroscopy (XANES), to understand the incorporation mechanism. Cl was found to be speciated as the Cl- anion within the glass phase, according to the characteristic chemical shift of the X-ray absorption edge. By comparison with Cl K-edge XANES data acquired from reference compounds, the local environment of the Cl- anion is most closely approximated by the mineral marialite, in which Cl is co-ordinate to 4 x Na and/or Ca atoms.


2002 ◽  
Vol 57 (5) ◽  
pp. 277-280 ◽  
Author(s):  
Yoshihiro Okamoto ◽  
Haruhiko Motohashi

The local structure of motlen ZrCl4 in LiCl-KCl eutectic was investigated by using an X-ray absorption fine structure (XAFS) of the Zr K-absorption edge. The nearest Zr4+-Cl- distance and coordination number from the curve fitting analysis were (2.51±0.02) Å and 5.9±0.6, respectively. These suggest that a 6-fold coordination (ZrCl6)2- is predominant in the molten mixture.


1971 ◽  
Vol 15 ◽  
pp. 285-294 ◽  
Author(s):  
J. H. McCrary ◽  
Ted Van Vorous

Recently developed, miniature, steady state, field emission tubes are finding application in several areas of x-ray analysis. These tubes require only a high voltage, low current power supply to produce relatively intense beams of x-rays. Since anodes can be fabricated from almost any element, and since the tubes can be operated at potentials up to about 70 kV, many different output x-ray spectra are available. Miniaturized battery operated x-ray sources of this type, occupying a volume of about one liter, have several advantages over radioisotope sources. These include cost, safety, and controllable output spectra and intensity. X-ray sources for energy dispersive fluorescence analyzers are designed so that no scattered characteristic radiations will interfer with the analysis of the sample fluorescence. Sources which are essentially monoenergetic can be fabricated for use in non-dispersive x-ray fluorescence analyzers. Because of the intensity and safety of the field emission tubes, such analyzers can be made which are sensitive while compact, portable, and inexpensive. In x-ray absorption analysis the measurement of absorption edge jump ratios provides a quantitative measure of sample impurities. Field emission tubes whose output spectra consist primarily of bremsstrahlung are particularly well suited to such measurements. The techniques involved in using these tubes in x-ray analysis are described.


Sign in / Sign up

Export Citation Format

Share Document