Miniature diamond anvils for X-ray Raman scattering spectroscopy experiments at high pressure

2017 ◽  
Vol 24 (1) ◽  
pp. 276-282 ◽  
Author(s):  
Sylvain Petitgirard ◽  
Georg Spiekermann ◽  
Christopher Weis ◽  
Christoph Sahle ◽  
Christian Sternemann ◽  
...  

X-ray Raman scattering (XRS) spectroscopy is an inelastic scattering method that uses hard X-rays of the order of 10 keV to measure energy-loss spectra at absorption edges of light elements (Si, Mg, Oetc.), with an energy resolution below 1 eV. The high-energy X-rays employed with this technique can penetrate thick or dense sample containers such as the diamond anvils employed in high-pressure cells. Here, we describe the use of custom-made conical miniature diamond anvils of less than 500 µm thickness which allow pressure generation of up to 70 GPa. This set-up overcomes the limitations of the XRS technique in very high-pressure measurements (>10 GPa) by drastically improving the signal-to-noise ratio. The conical shape of the base of the diamonds gives a 70° opening angle, enabling measurements in both low- and high-angle scattering geometry. This reduction of the diamond thickness to one-third of the classical diamond anvils considerably lowers the attenuation of the incoming and the scattered beams and thus enhances the signal-to-noise ratio significantly. A further improvement of the signal-to-background ratio is obtained by a recess of ∼20 µm that is milled in the culet of the miniature anvils. This recess increases the sample scattering volume by a factor of three at a pressure of 60 GPa. Examples of X-ray Raman spectra collected at the OK-edge and SiL-edge in SiO2glass at high pressures up to 47 GPa demonstrate the significant improvement and potential for spectroscopic studies of low-Zelements at high pressure.

2022 ◽  
Vol 93 (1) ◽  
pp. 015006
Author(s):  
Xiaolong Zhao ◽  
Ming Ye ◽  
Zhi Cao ◽  
Danyang Huang ◽  
Tingting Fan ◽  
...  

2011 ◽  
Vol 110 (10) ◽  
pp. 109902 ◽  
Author(s):  
Michael Chabior ◽  
Tilman Donath ◽  
Christian David ◽  
Manfred Schuster ◽  
Christian Schroer ◽  
...  

2003 ◽  
Vol 214 ◽  
pp. 70-83 ◽  
Author(s):  
T. P. Li

The energy range of hard X-rays is a key waveband to the study of high energy processes in celestial objects, but still remains poorly explored. In contrast to direct imaging methods used in the low energy X-ray and high energy gamma-ray bands, currently imaging in the hard X-ray band is mainly achieved through various modulation techniques. A new inversion technique, the direct demodulation method, has been developed since early 90s. with this technique, wide field and high resolution images can be derived from scanning data of a simple collimated detector. The feasibility of this technique has been confirmed by experiment, balloon-borne observation and analyzing simulated and real astronomical data. Based the development of methodology and instrumentation, a high energy astrophysics mission – Hard X-ray Modulation Telescope (HXMT) has been proposed and selected in China for a four-year Phase-A study. The main scientific objectives are a full-sky hard X-ray (20–200 keV) imaging survey and high signal-to-noise ratio timing studies of high energy sources.


2004 ◽  
Vol 78 (6) ◽  
pp. 915-919 ◽  
Author(s):  
N. Kalivas ◽  
L. Costaridou ◽  
I. Kandarakis ◽  
D. Cavouras ◽  
C.D. Nomicos ◽  
...  

Author(s):  
Timur Gureyev ◽  
David M. Paganin ◽  
Alex Kozlov ◽  
Harry Quiney

2005 ◽  
Vol 77 (20) ◽  
pp. 6563-6570 ◽  
Author(s):  
Zeng Ping Chen ◽  
Julian Morris ◽  
Elaine Martin ◽  
Robert B. Hammond ◽  
Xiaojun Lai ◽  
...  

2016 ◽  
Vol 22 (3) ◽  
pp. 536-543 ◽  
Author(s):  
Jong Seok Jeong ◽  
K. Andre Mkhoyan

AbstractAcquiring an atomic-resolution compositional map of crystalline specimens has become routine practice, thus opening possibilities for extracting subatomic information from such maps. A key challenge for achieving subatomic precision is the improvement of signal-to-noise ratio (SNR) of compositional maps. Here, we report a simple and reliable solution for achieving high-SNR energy-dispersive X-ray (EDX) spectroscopy spectrum images for individual atomic columns. The method is based on standard cross-correlation aided by averaging of single-column EDX maps with modifications in the reference image. It produces EDX maps with minimal specimen drift, beam drift, and scan distortions. Step-by-step procedures to determine a self-consistent reference map with a discussion on the reliability, stability, and limitations of the method are presented here.


2007 ◽  
Vol 22 (2) ◽  
pp. 108-112 ◽  
Author(s):  
Lars Ehm ◽  
Sytle M. Antao ◽  
Jiuhua Chen ◽  
Darren R. Locke ◽  
F. Marc Michel ◽  
...  

The method of high-energy total elastic X-ray scattering to determine the atomic structure of nanocrystalline, highly disordered, and amorphous materials is presented. The current state of the technique, its potential, and limitations are discussed with two successful studies on the pressure induced phase transition in mackinawite (FeS) and the high-pressure behavior of liquid gallium.


Sign in / Sign up

Export Citation Format

Share Document