Design of a wearable pain management system with embroidered TENS electrodes

2018 ◽  
Vol 30 (1) ◽  
pp. 38-48 ◽  
Author(s):  
Gozde Goncu Berk

Purpose The purpose of this paper is to develop a user friendly, wearable pain management system by optimizing CAD embroidery parameters for manufacturing high performance dry transcutaneous electrical neural stimulation (TENS) electrodes. Design/methodology/approach User-centered design methodology is employed to identify user needs related to TENS devices. Optimization of CAD embroidery parameters was done by measuring and calculating resistance and signal-to-noise values for electrodes manufactured with different conductive thread, stitch pattern, and stitch density types. Findings Characteristics of the conductive thread such as thickness and irregularity, embroidery stitch pattern, stitch density therefore the amount of conductive thread used all effect resistance values and signal-to-noise values of TENS electrodes. Low resistance of TENS electrode surface does not mean high signal-to-noise ratio and high TENS signal quality. Satin stitch type with low stitch density provides the best resistance and signal-to-noise ratio for a TENS electrode. Originality/value This study reported the design process of a wearable pain management system with a focus on optimization of embroidery manufacturing parameters for development of TENS electrodes. The design process not only required technical optimization but also understanding user problems related to use of conventional TENS devices. Proposed end product is a user friendly, electronic textile based, wireless wearable pain management system in different forms suitable for major pain areas such as knee, elbow and neck.

Author(s):  
William Ferris ◽  
Larry Albert DeWerd ◽  
Wesley S Culberson

Abstract Objective: Synchrony® is a motion management system on the Radixact® that uses planar kV radiographs to locate the target during treatment. The purpose of this work is to quantify the visibility of fiducials on these radiographs. Approach: A custom acrylic slab was machined to hold 8 gold fiducials of various lengths, diameters, and orientations with respect to imaging axis. The slab was placed on the couch at the imaging isocenter and planar radiographs were acquired perpendicular to the custom slab with varying thicknesses of acrylic on each side. Fiducial signal to noise ratio (SNR) and detected fiducial position error in millimeters were quantified. Main Results: The minimum output protocol (100 kVp, 0.8 mAs) was sufficient to detect all fiducials on both Radixact configurations when the thickness of the phantom was 20 cm. However, no fiducials for any protocol were detected when the phantom was 50 cm thick. The algorithm accurately detected fiducials on the image when the SNR was larger than 4. The MV beam was observed to cause RFI artifacts on the kV images and to decrease SNR by an average of 10%. Significance: This work provides the first data on fiducial visibility on kV radiographs from Radixact Synchrony treatments. The Synchrony fiducial detection algorithm was determined to be very accurate when sufficient SNR is achieved. However, a higher output protocol may need to be added for use with larger patients. This work provided groundwork for investigating visibility of fiducial-free solid targets in future studies and provided a direct comparison of fiducial visibility on the two Radixact configurations, which will allow for intercomparison of results between configurations.


Circuit World ◽  
2019 ◽  
Vol 45 (3) ◽  
pp. 156-168 ◽  
Author(s):  
Yavar Safaei Mehrabani ◽  
Mehdi Bagherizadeh ◽  
Mohammad Hossein Shafiabadi ◽  
Abolghasem Ghasempour

Purpose This paper aims to present an inexact 4:2 compressor cell using carbon nanotube filed effect transistors (CNFETs). Design/methodology/approach To design this cell, the capacitive threshold logic (CTL) has been used. Findings To evaluate the proposed cell, comprehensive simulations are carried out at two levels of the circuit and image processing. At the circuit level, the HSPICE software has been used and the power consumption, delay, and power-delay product are calculated. Also, the power-delaytransistor count product (PDAP) is used to make a compromise between all metrics. On the other hand, the Monte Carlo analysis has been used to scrutinize the robustness of the proposed cell against the variations in the manufacturing process. The results of simulations at this level of abstraction indicate the superiority of the proposed cell to other circuits. At the application level, the MATLAB software is also used to evaluate the peak signal-to-noise ratio (PSNR) figure of merit. At this level, the two primary images are multiplied by a multiplier circuit consisting of 4:2 compressors. The results of this simulation also show the superiority of the proposed cell to others. Originality/value This cell significantly reduces the number of transistors and only consists of NOT gates.


2009 ◽  
Vol 36 (11) ◽  
pp. 5214-5220 ◽  
Author(s):  
Frédéric Lacroix ◽  
A. Sam Beddar ◽  
Mathieu Guillot ◽  
Luc Beaulieu ◽  
Luc Gingras

Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Author(s):  
D. C. Joy ◽  
R. D. Bunn

The information available from an SEM image is limited both by the inherent signal to noise ratio that characterizes the image and as a result of the transformations that it may undergo as it is passed through the amplifying circuits of the instrument. In applications such as Critical Dimension Metrology it is necessary to be able to quantify these limitations in order to be able to assess the likely precision of any measurement made with the microscope.The information capacity of an SEM signal, defined as the minimum number of bits needed to encode the output signal, depends on the signal to noise ratio of the image - which in turn depends on the probe size and source brightness and acquisition time per pixel - and on the efficiency of the specimen in producing the signal that is being observed. A detailed analysis of the secondary electron case shows that the information capacity C (bits/pixel) of the SEM signal channel could be written as :


1979 ◽  
Vol 10 (4) ◽  
pp. 221-230 ◽  
Author(s):  
Veronica Smyth

Three hundred children from five to 12 years of age were required to discriminate simple, familiar, monosyllabic words under two conditions: 1) quiet, and 2) in the presence of background classroom noise. Of the sample, 45.3% made errors in speech discrimination in the presence of background classroom noise. The effect was most marked in children younger than seven years six months. The results are discussed considering the signal-to-noise ratio and the possible effects of unwanted classroom noise on learning processes.


2020 ◽  
Vol 63 (1) ◽  
pp. 345-356
Author(s):  
Meital Avivi-Reich ◽  
Megan Y. Roberts ◽  
Tina M. Grieco-Calub

Purpose This study tested the effects of background speech babble on novel word learning in preschool children with a multisession paradigm. Method Eight 3-year-old children were exposed to a total of 8 novel word–object pairs across 2 story books presented digitally. Each story contained 4 novel consonant–vowel–consonant nonwords. Children were exposed to both stories, one in quiet and one in the presence of 4-talker babble presented at 0-dB signal-to-noise ratio. After each story, children's learning was tested with a referent selection task and a verbal recall (naming) task. Children were exposed to and tested on the novel word–object pairs on 5 separate days within a 2-week span. Results A significant main effect of session was found for both referent selection and verbal recall. There was also a significant main effect of exposure condition on referent selection performance, with more referents correctly selected for word–object pairs that were presented in quiet compared to pairs presented in speech babble. Finally, children's verbal recall of novel words was statistically better than baseline performance (i.e., 0%) on Sessions 3–5 for words exposed in quiet, but only on Session 5 for words exposed in speech babble. Conclusions These findings suggest that background speech babble at 0-dB signal-to-noise ratio disrupts novel word learning in preschool-age children. As a result, children may need more time and more exposures of a novel word before they can recognize or verbally recall it.


Author(s):  
Yu ZHOU ◽  
Wei ZHAO ◽  
Zhixiong CHEN ◽  
Weiqiong WANG ◽  
Xiaoni DU

2020 ◽  
Vol 2020 (7) ◽  
pp. 143-1-143-6 ◽  
Author(s):  
Yasuyuki Fujihara ◽  
Maasa Murata ◽  
Shota Nakayama ◽  
Rihito Kuroda ◽  
Shigetoshi Sugawa

This paper presents a prototype linear response single exposure CMOS image sensor with two-stage lateral overflow integration trench capacitors (LOFITreCs) exhibiting over 120dB dynamic range with 11.4Me- full well capacity (FWC) and maximum signal-to-noise ratio (SNR) of 70dB. The measured SNR at all switching points were over 35dB thanks to the proposed two-stage LOFITreCs.


Sign in / Sign up

Export Citation Format

Share Document