A Numerically Efficient Iterative Procedure for Hybrid Power System Optimization Using Sensitivity Functions

Author(s):  
Gayathri Seenumani ◽  
Jing Sun ◽  
Huei Peng
Electronics ◽  
2020 ◽  
Vol 9 (11) ◽  
pp. 1971
Author(s):  
Sonia Leva ◽  
Francesco Grimaccia ◽  
Marco Rozzi ◽  
Matteo Mascherpa

One of the common problems faced by Telecommunication (TLC) companies is the lack of power supply, usually for those appliances with scarce chances of grid connection often placed in remote zones. This issue is more and more critical if the radio network has the specific task of guaranteeing the so-called “mission-critical communications”. This manuscript aims to propose and assess a viable solution to optimize the power supply and maintenance operations required to assure the proper functionality in such critical and remote sites. In particular, the main goals are defining a method to select the critical sites in an extensive and composite radio system and designing the hybrid power system in a way to improve the service availability and technical-economic benefits of the whole mission-critical TLC system. Finally, the proposed method and related procedures are tested and validated in a real scenario.


2019 ◽  
Vol 139 (4) ◽  
pp. 259-268
Author(s):  
Effat Jahan ◽  
Md. Rifat Hazari ◽  
Mohammad Abdul Mannan ◽  
Atsushi Umemura ◽  
Rion Takahashi ◽  
...  

Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1889 ◽  
Author(s):  
Nicu Bizon ◽  
Valentin Alexandru Stan ◽  
Angel Ciprian Cormos

In this paper, a systematic analysis of seven control topologies is performed, based on three possible control variables of the power generated by the Fuel Cell (FC) system: the reference input of the controller for the FC boost converter, and the two reference inputs used by the air regulator and the fuel regulator. The FC system will generate power based on the Required-Power-Following (RPF) control mode in order to ensure the load demand, operating as the main energy source in an FC hybrid power system. The FC system will operate as a backup energy source in an FC renewable Hybrid Power System (by ensuring the lack of power on the DC bus, which is given by the load power minus the renewable power). Thus, power requested from the batteries’ stack will be almost zero during operation of the FC hybrid power system based on RPF-control mode. If the FC hybrid power system operates with a variable load demand, then the lack or excess of power on the DC bus will be dynamically ensured by the hybrid battery/ultracapacitor energy storage system for a safe transition of the FC system under the RPF-control mode. The RPF-control mode will ensure a fair comparison of the seven control topologies based on the same optimization function to improve the fuel savings. The main objective of this paper is to compare the fuel economy obtained by using each strategy under different load cycles in order to identify which is the best strategy operating across entire loading or the best switching strategy using two strategies: one strategy for high load and the other on the rest of the load range. Based on the preliminary results, the fuel consumption using these best strategies can be reduced by more than 15%, compared to commercial strategies.


Sign in / Sign up

Export Citation Format

Share Document