Multi-slot stack-type ring resonator for high sensitivity biosensor and low voltage optical modulator

Author(s):  
Yoshiteru Amemiya ◽  
Tomoya Taniguchi ◽  
Takeshi Ikeda ◽  
Masataka Fukuyama ◽  
Akio Kuroda ◽  
...  
Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3385
Author(s):  
Jialu Ma ◽  
Jingchao Tang ◽  
Kaicheng Wang ◽  
Lianghao Guo ◽  
Yubin Gong ◽  
...  

A complex permittivity characterization method for liquid samples has been proposed. The measurement is carried out based on a self-designed microwave sensor with a split ring resonator (SRR), the unload resonant frequency of which is 5.05 GHz. The liquid samples in capillary are placed in the resonant zone of the fabricated senor for high sensitivity measurement. The frequency shift of 58.7 MHz is achieved when the capillary is filled with ethanol, corresponding a sensitivity of 97.46 MHz/μL. The complex permittivity of methanol, ethanol, isopropanol (IPA) and deionized water at the resonant frequency are measured and calibrated by the first order Debye model. Then, the complex permittivity of different concentrations of aqueous solutions of these materials are measured by using the calibrated sensor system. The results show that the proposed sensor has high sensitivity and accuracy in measuring the complex permittivity of liquid samples with volumes as small as 0.13 μL. It provides a useful reference for the complex permittivity characterization of small amount of liquid chemical samples. In addition, the characterization of an important biological sample (inositol) is carried out by using the proposed sensor.


2018 ◽  
Vol 0 (0) ◽  
Author(s):  
Sana Rebhi ◽  
Radhouene Massoudi ◽  
Monia Najjar

AbstractIn this paper, an ultra-fast all-optical modulator, based on a new shape of nonlinear photonic crystal ring resonator, is designed and studied. Numerical methods such as plane wave expansion (PWE) and finite-difference time domain (FDTD) are used to perform simulations. The modulation technique consists of carrier light controlling by means of input light signal and Kerr effect. The investigation of extinction ratio and insertion loss within the carrier input power shows that the choice of 0.7 W is the optimal value of that power to ensure the tradeoff between both characteristics. The suggested modulator demonstrates an excellent extinction ratio about 20.8018, a very low insertion loss of −13.98 and a short switching time about 13.4 ps. According to the obtained results, the modulator can be considered as an ultra-fast and ultra-compact optical component.


2018 ◽  
Vol 407 ◽  
pp. 271-274 ◽  
Author(s):  
Sizhu Shao ◽  
Jianfeng Ding ◽  
Lei Zhang ◽  
Xin Fu ◽  
Lin Yang

MRS Bulletin ◽  
2009 ◽  
Vol 34 (9) ◽  
pp. 658-664 ◽  
Author(s):  
P. Muralt ◽  
R. G. Polcawich ◽  
S. Trolier-McKinstry

AbstractPiezoelectric microelectromechanical systems (MEMS) offer the opportunity for high-sensitivity sensors and large displacement, low-voltage actuators. In particular, recent advances in the deposition of perovskite thin films point to a generation of MEMS devices capable of large displacements at complementary metal oxide semiconductor-compatible voltage levels. Moreover, if the devices are mounted in mechanically noisy environments, they also can be used for energy harvesting. Key to all of these applications is the ability to obtain high piezoelectric coefficients and retain these coefficients throughout the microfabrication process. This article will review the impact of composition, orientation, and microstructure on the piezoelectric properties of perovskite thin films such as PbZr1−xTixO3 (PZT). Superior piezoelectric coefficients (e31, f of −18 C/m2) are achieved in {001}-oriented PbZr0.52Ti0.48O3 films with improved compositional homogeneity on Si substrates. The advent of such high piezoelectric responses in films opens up a wide variety of possible applications. A few examples of these, including low-voltage radio frequency MEMS switches and resonators, actuators for millimeter-scale robotics, droplet ejectors, energy scavengers for unattended sensors, and medical imaging transducers, will be discussed.


2001 ◽  
Vol 705 ◽  
Author(s):  
Hengpeng Wu ◽  
Kenneth E. Gonsalves

AbstractA photoacid generating (PAG) sulfonium monomer was designed and synthesized. CA resists were prepared based on this PAG monomer. Incorporation of the PAG in the resist backbone offered a few advantages such as high sensitivity and absence of phase separation. These resists proved to be especially useful for low-voltage EB lithography.


Author(s):  
Hui-Hui Zhu ◽  
Yong-Heng Yue ◽  
Ya-Jie Wang ◽  
Min Zhang ◽  
Jian-Jun He ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document