Research on Excitation Voltage Frequency and Amplitude Dependence of Iron Core Vibration of HVDC Converter Transformer

Author(s):  
Zhicheng Pan ◽  
Jun Deng ◽  
Jinwei Chu ◽  
Jinyin Zhang ◽  
Zhicheng Xie ◽  
...  
1986 ◽  
Vol 47 (C8) ◽  
pp. C8-1155-C8-1157
Author(s):  
E. C. THEIL ◽  
D. E. SAYERS ◽  
C. Y. YANG ◽  
A. FONTAINE ◽  
E. DARTYGE

2020 ◽  
Vol 7 (3) ◽  
pp. 11-22
Author(s):  
VALERY ANDREEV ◽  
◽  
ALEXANDER POPOV

A reduced model has been developed to describe the time evolution of a discharge in an iron core tokamak, taking into account the nonlinear behavior of the ferromagnetic during the discharge. The calculation of the discharge scenario and program regime in the tokamak is formulated as an inverse problem - the optimal control problem. The methods for solving the problem are compared and the analysis of the correctness and stability of the control problem is carried out. A model of “quasi-optimal” control is proposed, which allows one to take into account real power sources. The discharge scenarios are calculated for the T-15 tokamak with an iron core.


2012 ◽  
Vol 132 (4) ◽  
pp. 480-486 ◽  
Author(s):  
Masanobu Kakihara ◽  
Toshiyuki Hoshi ◽  
Toru Shikayama ◽  
Motomichi Ohto

2015 ◽  
Vol 135 (12) ◽  
pp. 711-716
Author(s):  
Hiroyuki Fujita ◽  
Kenichi Kawamura ◽  
Keizo Inagaki
Keyword(s):  

2017 ◽  
Vol 3 (2) ◽  
pp. 88
Author(s):  
Suci Rahmatia ◽  
Marsah Zaysi Makhudzia

<p><em>Abstrak <strong>- </strong></em><strong>Transformator adalah peralatan listrik yang sangat vital dalam proses pembangkitan maupun transmisi energi listrik karena transformator dapat menaikkan atau menurunkan tegangan. Pada proses menaikkan dan menurunkan tegangan biasanya sering timbul panas akibat rugi – rugi tembaga pada inti besi dan kumparannya sehingga pada kondisi overload akan menimbulkan pemanasan yang berlebih dan dapat mempengaruhi kinerja transformator. Oleh karena itu dibuat sistem kontrol temperatur pada transformer yang dapat mengontrol temperatur di dalam transformator saat bekerja pada kondisi overload, sehigga transformatornya tidak terbakar. Dial thermometer digunakan sebagai alat yang mengontrol temperatur transformator pada sistem kontrol temperatur. Agar mendapatkan sistem kontrol yang optimal, maka setting temperatur pada dial thermometer di sesuaikan dengan temperatur maksimal tranformator dapat bekerja. Sehingga pada saat temperatur tertentu dial thermometer dapat memberikan sinyal untuk membunyikan alarm dan mengaktifkan kontrol kipas sehingga kipas dapat bekerja menurunkan temperatur transformator.<em></em></strong></p><p><strong><em> </em></strong></p><p><strong><em>Kata kunci - </em></strong><em>transformator, rugi – rugi tembaga, temperatur, sistem kontrol, dial thermometer<strong>.</strong></em></p><p><strong><em> </em></strong></p><p><em>Abstract <strong>- </strong></em><strong>A transformer is an electrical device that is vital in the generation and transmission of electrical energy because the transformer can raise (stepping up) or lower (stepping down) the voltage. In the process of raising and lowering the voltage is usually often caused heat loss of copper in iron core and coil so that the overload condition will cause excessive warming and can affect the performance of the transformer. Therefore, a temperature control system on the transformer can control the temperature inside the transformer while working under overload conditions, so the transformer is not burned. Dial thermometer is used as a device that controls the temperature of the transformer in the temperature control system. In order to obtain an optimal control system, the temperature setting on the dial thermometer adjusted to the maximum transformer temperature can work. So that when a certain temperature dial thermometer can provide a signal to sound the alarm and activate the fan control so that the fan can work down the transformer temperature.</strong></p><p><strong> </strong></p><p><strong><em>Keywords -  </em></strong><em>transformator, loss of copper, themperature, control system, dial thermometer<strong></strong></em></p>


Author(s):  
Zhengwang Xu ◽  
Guozhuang Jiang ◽  
Ke Kun ◽  
Yuchun Yi

Background: The output voltage frequency for the previously proposed "phase hopping" AC-AC frequency conversion technology is determined by the law that the number of output voltage cycles is reduced by one relative to the power frequency in a large cycle containing six jumps. According to the law, only a limited number of output frequencies, such as 37.5 Hz, 42.86 Hz and 45 Hz are found. Due to the large spacing between the output frequencies, the "phase hopping" frequency conversion technology is difficult to put into practical use. Methods: In this paper, the law of the output frequency control is generalized so that the number of output cycles in a large cycle is reduced by n relative to the power frequency. The analysis shows that the appropriate selection of large cycles, including the number of power frequency cycles and the value of n, can find more frequencies to be used. Reducing the interval between the output frequencies within 1Hz. Results: The analysis results were verified in simulation by MATLAB, and the harmonics and the feasibility of the actual application were analyzed. Conclusion: Finally, an experimental platform was built and an experimental analysis was carried out. The experimental results show that the theoretical and simulation analyses are correct.


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 697
Author(s):  
Hanqing Xu ◽  
Weijun Fan ◽  
Jianwei Feng ◽  
Peiliang Yan ◽  
Shuchan Qi ◽  
...  

Flame monitoring of industrial combustors with high-reliability sensors is essential to operation security and performance. An ion current flame sensor with a simple structure has great potential to be widely used, but a weak ion current is the critical defect to its reliability. In this study, parameters of the ion current sensor used for monitoring flames on a Bunsen burner are suggested, and a method of further improving the ion current is proposed. Effects of the parameters, including the excitation voltage, electrode area, and electrode radial and vertical positions on the ion current, were investigated. The ion current grew linearly with the excitation voltage. Given that the electrodes were in contact with the flame fronts, the ion current increased with the contact area of the cathode but independent of the contact area of the anode. The smaller electrode radial position resulted in a higher ion current. The ion current was insensitive to the anode vertical position but largely sensitive to the cathode vertical position. Based on the above ion current regularities, the sensor parameters were suggested as follows: The burner served as a cathode and the platinum wire acted as an anode. The excitation voltage, anode radial and vertical positions were 120 V, 0 mm, and 6 mm, respectively. The method of further improving the ion current by adding multiple sheet cathodes near the burner exit was proposed and verified. The results show that the ion current sensor with the suggested parameters could correctly identify the flame state, including the ignition, combustion, and extinction, and the proposed method could significantly improve the magnitude of the ion current.


Sign in / Sign up

Export Citation Format

Share Document