Advanced Operation for Micro-Grid on Residential Properties for Network Power Stability During Peak Load

Author(s):  
Mohamad Nassereddine ◽  
Vinod Pangracious
Author(s):  
Maheswari M. ◽  
Gunasekharan S.

The demand for electricity is increasing day by day due to technological advancements. According to the demand, the size of the grid is also increasing rapidly in the past decade. However, the traditional centralized power grid has many drawbacks such as high operating cost, customer satisfaction, less reliability, and security. Distribution generation has less pollution, high energy efficiency, and flexible installation than traditional generation. It also improves the performance of the grid in peak load and reliability of supply. The concept of micro-grid has been raised due to the advent of new technologies and development of the power electronics and modern control theory. Micro-grid is the significant part of the distribution network in the future of smart grid, which has advanced and flexible operation and control pattern, and integrates distributed clean energy.


Author(s):  
Srete Nikolovski ◽  
Hamid Reza Baghaee ◽  
Dragan Mlakić

One of the most crucial and economically beneficial tasks for energy customer is peak load curtailment. On account of the fast response of renewable energy resources (RERs) such as photovoltaic (PV) units and battery energy storage system (BESS), this task is closer to be efficiently implemented. Depends on the customer peak load demand and energy characteristics, the feasibility of this strategy may warry. When adaptive neuro-fuzzy inference system (ANFIS) is exploited for forecasting, it can provide many benefits to address the above-mentioned issues and facilitate its easy implementation, with short calculating time and re-trainability. This paper introduces a data driven forecasting method based on fuzzy logic for optimized peak load reduction. First, the amount of energy generated by PV is forecasted using ANFIS which conducts output trend, and then, the BESS capacity is calculated according to the forecasted results. The trend of the load power is then decomposed in Cartesian plane into two parts, left and right from load peak, searching for BESS capacity equal. Network switching sequence over consumption is provided by a fuzzy logic controller (FLC) with respect to BESS capacity and PV energy output. Finally, to prove the effectiveness of the proposed ANFIS-based peak shaving method, offline digital time-domain simulations have been performed on a real-life practical test micro grid system in MATLAB/Simulink environment and the results have been experimentally verified by testing on a practical micro grid system with real-life data obtained from smart meter and also, compared with several previously-reported methods.


2021 ◽  
Vol 11 (16) ◽  
pp. 7178
Author(s):  
Gábor Pintér ◽  
András Vincze ◽  
Nóra Hegedűsné Baranyai ◽  
Henrik Zsiborács

With the dynamic growth in both the global hunger for electrical energy and the share of variable renewable energy sources in the energy mix, distribution networks are facing new challenges where conventional solutions may not be the best ones. The increase in load in distribution grids is routinely countered by network development and expansion, in a great part to supply for on-peak load demand, which could also be done by utilizing supplementary technologies to lessen the need for or defer such expansion. Vehicle-to-grid technology could efficiently contribute to handling this issue, as electric vehicles can potentially function as storage capacities to mitigate the fluctuations of power generation. The battery energy storage systems of hybrid or completely electric watercraft, which are becoming increasingly popular, are no exception, either. These vehicles represent a considerable potential to create more complex vehicle-to-grid solutions for countries with significant inland or seaport networks, for example, Hungary, with the largest lake of Central Europe. Since there is only deficient information on the topic, the main goal of this study was to explore the energy storage capacities of small electric boats in the context of Lake Balaton, Hungary. By this example, the paper presents the potential utilization of Europe’s significant network of sea and inland recreational ports for the purpose of energy storage. Similarly to other European countries, Hungary’s energy strategy for 2030 also includes the promotion of virtual production integration, local energy communities and micro-grid solutions. At the beginning of 2021, the small electric boats in the sailing marinas of Lake Balaton represented a cumulative energy storage capacity of 4.8 MWh, which may reach even 15.6 MWh by 2030, by the promotion of micro-grid solutions. The innovative novelty of this study is that it regards small fully electric boats not just as vehicles, but also explores their energy storage potentials. The novel goal of these examinations is to explore the volume of the energy storage potentials of the small fully electric boats around Lake Balaton, the knowledge of which may facilitate the creation of new types of flexibility services related to energy storage.


2022 ◽  
pp. 1437-1458
Author(s):  
Maheswari M. ◽  
Gunasekharan S.

The demand for electricity is increasing day by day due to technological advancements. According to the demand, the size of the grid is also increasing rapidly in the past decade. However, the traditional centralized power grid has many drawbacks such as high operating cost, customer satisfaction, less reliability, and security. Distribution generation has less pollution, high energy efficiency, and flexible installation than traditional generation. It also improves the performance of the grid in peak load and reliability of supply. The concept of micro-grid has been raised due to the advent of new technologies and development of the power electronics and modern control theory. Micro-grid is the significant part of the distribution network in the future of smart grid, which has advanced and flexible operation and control pattern, and integrates distributed clean energy.


The analysis of the previous results of the study on concrete stress-strain behavior at elevated temperatures has been carried out. Based on the analysis, the main reasons for strength retrogression and elastic modulus reduction of concrete have been identified. Despite a significant amount of research in this area, there is a large spread in experimental data received, both as a result of compression and tension. In addition, the deformation characteristics of concrete are insufficiently studied: the coefficient of transverse deformation, the limiting relative compression deformation corresponding to the peak load and the almost complete absence of studies of complete deformation diagrams at elevated temperatures. The two testing chambers provided creating the necessary temperature conditions for conducting studies under bending compression and tension have been developed. On the basis of the obtained experimental data of physical and mechanical characteristics of concrete at different temperatures under conditions of axial compression and tensile bending, conclusions about the nature of changes in strength and deformation characteristics have been drawn. Compression tests conducted following the method of concrete deformation complete curves provided obtaining diagrams not only at normal temperature, but also at elevated temperature. Based on the experimental results, dependences of changes in prism strength and elastic modulus as well as an equation for determining the relative deformation and stresses at elevated temperatures at all stages of concrete deterioration have been suggested.


Problems when calculating reinforced concrete structures based on the concrete deformation under compression diagram, which is presented both in Russian and foreign regulatory documents on the design of concrete and reinforced concrete structures are considered. The correctness of their compliance for all classes of concrete remains very approximate, especially a significant difference occurs when using Euronorm due to the different shape and sizes of the samples. At present, there are no methodical recommendations for determining the ultimate relative deformations of concrete under axial compression and the construction of curvilinear deformation diagrams, which leads to limited experimental data and, as a result, does not make it possible to enter more detailed ultimate strain values into domestic standards. The results of experimental studies to determine the ultimate relative deformations of concrete under compression for different classes of concrete, which allowed to make analytical dependences for the evaluation of the ultimate relative deformations and description of curvilinear deformation diagrams, are presented. The article discusses various options for using the deformation model to assess the stress-strain state of the structure, it is concluded that it is necessary to use not only the finite values of the ultimate deformations, but also their intermediate values. This requires reliable diagrams "s–e” for all classes of concrete. The difficulties of measuring deformations in concrete subjected to peak load, corresponding to the prismatic strength, as well as main cracks that appeared under conditions of long-term step loading are highlighted. Variants of more accurate measurements are proposed. Development and implementation of the new standard GOST "Concretes. Methods for determination of complete diagrams" on the basis of the developed method for obtaining complete diagrams of concrete deformation under compression for the evaluation of ultimate deformability of concrete under compression are necessary.


Sign in / Sign up

Export Citation Format

Share Document