Experimental study and characterization of Chitosan-HAP composite as orthopedic implant material

Author(s):  
S. Chatterjee ◽  
A. Chanda ◽  
K. Pal
e-Polymers ◽  
2020 ◽  
Vol 20 (1) ◽  
pp. 69-75
Author(s):  
Haoran Yun ◽  
Xingxiang Zhang

AbstractMicrospheres with phase change properties were fabricated by polymerization of hexadecyl acrylate (HA) and different cross-linking agents. The samples were characterized by scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FTIR), thermal gravimetric analysis (TGA). The results show that, the samples that added cross-linking agents have a smooth surface and the latent heat of them is different. The experiments show that all of the cross-linked copolymer shells can be made into temperature controlled release microspheres. These materials can be potentially applied in the field of thermal energy storage. β-tricalcium phosphate was encapsulated in microspheres to obtain one with a fast release effect. It will effectively promote bone conduction when these microspheres were implanted into a bone defect. This microsphere can be used for orthopedic implant or coating of instrument in the future.


2008 ◽  
Vol 85A (4) ◽  
pp. 1022-1031 ◽  
Author(s):  
Gianluca Giavaresi ◽  
Milena Fini ◽  
Roberto Chiesa ◽  
Carmen Giordano ◽  
Enrico Sandrini ◽  
...  

Author(s):  
Katsumasa Miyazaki ◽  
Kunio Hasegawa ◽  
Koichi Saito ◽  
Bostjan Bezensek

The fitness-for-service code requires the characterization of non-aligned multiple flaws for the flaw evaluation, which is performed using a flaw proximity rule. Worldwide almost all codes provide own proximity rule, often with unclear technical bases of the application of proximity rule to ductile fracture. To clarify the appropriate proximity rule for non-aligned multiple flaws in fully plastic fracture, fracture tests on flat plate specimen with non-aligned multiple through wall flaws were conducted at ambient temperature. The emphasis of this study was put on the flaw alignment rule, which determines whether non-aligned flaws are treated as independent or aligned onto the same plane for the purpose of flaw evaluations. The effects of the flaw separation and flaw size on the maximum load were investigated. The experimental results were compared with the estimations of the collapse load using the alignment rules in the ASME Section XI, BS7910 and API 579-1 codes. A new estimation procedure specific to the fully plastic fracture was proposed and compared with the comparison with the experimental results.


Measurement ◽  
2021 ◽  
pp. 109608
Author(s):  
Zhifeng Liu ◽  
Mingpo Zheng ◽  
Jinfei Guo ◽  
Hongyan Chu ◽  
Xing Yan ◽  
...  

Author(s):  
Xiangji Liu ◽  
yihang Ma ◽  
Yuhang Zhu ◽  
Minjiang Chen ◽  
Jiansong Ji ◽  
...  

Hydroxyapatite (HA) is the most commonly used orthopedic implant material. In recent years, the emergence of cationic doped hydroxyapatite has revealed more possibilities for the biological application of HA. Conventional...


2012 ◽  
Vol 11 (04) ◽  
pp. 1240021
Author(s):  
GUILLAUME LAFFITE ◽  
XU ZHENG ◽  
LOUIS RENAUD ◽  
FRANÇOIS BESSUEILLE ◽  
ELISABETH CHARLAIX ◽  
...  

We present an experimental study on the electrofluidic transistor in this paper. A novel and easy way to integrate the transistor into a microchannel is developed. The performances of the insulating layer, especially the leakage current under gate voltage, are carefully characterized. The change of surface charge on silica surface by gate polarization is measured, however, by measuring the streaming current, the gating effect on zeta potential has not been observed. This result should imply new assumption in the understanding of the charge regulation in the electrical double layer under gate polarization.


Sign in / Sign up

Export Citation Format

Share Document