Control strategies for high frequency voltage source converter for ozone generation

Author(s):  
Jakson P. Bonaldo ◽  
Jose A. Pomilio
Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2260
Author(s):  
Fan Cheng ◽  
Lijun Xie ◽  
Zhibing Wang

This paper investigated the characteristics of a novel type of hybrid high voltage direct current (HVdc) converter, which is composed by line commutated converter series with voltage source converter. The system and valve level control strategies are introduced, which can provide ac system voltage support. A novel filter design scheme composed by resonant filers for hybrid HVdc are also proposed, which can decrease the capacity of reactive power compensation equipment without deteriorate harmonic characteristics. The ac voltage of HVdc fluctuation level caused by transmitted power variation will be effectively reduced, with the coordination between filter design scheme and converter control. In addition, the influence of ac grid strength is also analyzed by equivalent source internal impedance represented by short circuit ratio (SCR). Finally, the +800 kV/1600 MW hybrid HVdc system connecting two ac grids under different SCR cases are studied, and the PSCAD/EMTDC simulation results have validated the effectiveness for proposed strategy.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1591
Author(s):  
Bo Pang ◽  
Feng Li ◽  
Hui Dai ◽  
Heng Nian

High frequency resonance (HFR) is a subsistent problem which affects the operation of the voltage source converter (VSC) connected to the parallel compensated grid. The appearance of HFR introduces a significant high frequency component in the grid voltage, thereby the operation of VSC system will be seriously affected. For enhancing the operation capability of VSC system, an HFR damping method based on the voltage feedforward control is proposed in this paper, which can reshape the VSC system impedance effectively in a wideband range. Besides, different with the existing HFR damping methods, the proposed method introduces a correction factor instead of the series virtual impedance with fixed value, so that the effect of impedance reshaping is irrelevant to the parameters of controlled object. In addition, this paper analyzes the fundamental control performance of VSC system after equipping the proposed method, for verifying that the proposed method will not worsen the fundamental control. Experimental results are given to validate the effectiveness of the proposed damping method.


Author(s):  
V. Ramesh ◽  
Y. Kusuma Latha

There is a great concern of torque ripple and power quality of three phase voltage source converter fed Permanent Magnet Brushless DC Motor (PMBLDCM). In this paper, two control strategies for BLDC motor drive has been investigated. One of the control strategies is based on PFC - CUK converter fed PMBLDCM drive and another one is PFC- interleaved boost converter fed BLDC motor drive. Comparison has been made between the two control stragies in terms of Torque ripple, Total harmonic distortion (THD) and power factor for different operating speeds. The proposed work as been implemented under MATLAB/simulink environment. Simulation results are presented to validate proposed work. From the results, it is observed that PFC interleaved Boost converter fed BLDC motor drive is more effective compared to CUK converter fed BLDC motor drive.


Author(s):  
Suresh Mikkili ◽  
Adinarayana Padamati

Abstract In this research paper, the shunt active filter (SHAF) is used to improve the power quality of electrical network by mitigating the harmonics with the help of different control strategies (p-q control strategy, Id-Iq control strategy, PHC control strategy) for three phase three wire system. It is quite difficult to optimize the performance of power system networks using conventional methods, because of complex nature of the systems that are highly non-linear and non-stationary. Three phase reference current waveforms generated by the proposed schemes are tracked by three phase voltage source converter in a hysteresis band control scheme. The performance of proposed control strategies has been evaluated in terms of harmonic mitigation and DC link voltage regulation under various source voltage conditions. The proposed SHAF with different control strategies is able to eliminate uncertainty in the system and SHAF gains outstanding compensation abilities. The detailed simulation results using MATLAB/Simulink software are presented to support the feasibility of the proposed control strategy.


1982 ◽  
Vol IA-18 (3) ◽  
pp. 279-287 ◽  
Author(s):  
V. T. Ranganathan ◽  
Phoivos D. Ziogas ◽  
Victor R. Stefanovic

2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Qing Zhong ◽  
Junjie Feng ◽  
Gang Wang ◽  
Haifeng Li

With the development of distributed generations (DGs), single-phase voltage source converter (SPVSC) has been widely used, but it brings about the problem of harmonic pollution to power grid. Hence, it is significant to explore the mechanism of harmonic injection from SPVSC and propose effective control strategies to mitigate the harmonic pollution. In this paper, a harmonic analysis model of SPVSC based on dynamic phasor (DP) has been established. With the model, the harmonics interaction between the ac side and the dc side can be analyzed with the consideration of the control strategies, which reveals the generation mechanism of the harmonics in SPVSC. Based on the mechanism, a feedforward harmonic mitigation strategy has been presented. The principle of the strategy is to add low-order harmonic signal to the PWM modulation signals to reduce the harmonic current on the ac side. The harmonic mitigation strategy not only has clear physical meaning and fast calculation, but also is robust for the uncertainty of parameters. Finally, the simulation and experiment results demonstrate the correctness of the model and the effectiveness of the harmonic mitigation strategy.


2014 ◽  
Vol 521 ◽  
pp. 222-228
Author(s):  
Kai Wang ◽  
Hai Shun Sun ◽  
Yu Hua ◽  
Yuan Liu ◽  
Wei Xing Lin ◽  
...  

The continuous development of alternative energy has put forward higher requirement for electricity transmission. To cope with its fluctuation characteristics, high voltage direct current (HVDC) technology has received more attention. Voltage Source Converter (VSC) based Multi-Terminal High Voltage Direct Current (MTDC) represents the future trend of HVDC technology. This paper mainly focuses on the control strategies of a four-terminal VSC based MTDC power transmission system. The operation characteristic of the system was studied, and the proposed two control strategies, master-slave control strategy and DC voltage droop control strategy, were verified through simulations. The latter control strategy was proved to be performing well under various conditions, including converter station disconnection and faults at AC side of the converter.


Sign in / Sign up

Export Citation Format

Share Document