Selection of Personalized Parameters of the Object Model in a Closed Control System of the Blood Glucose Level

Author(s):  
Anatolii Mikhalskii ◽  
Janna Novoseltseva
2016 ◽  
Vol 25 (12) ◽  
pp. 1650161 ◽  
Author(s):  
Sawsan Morkos Gharghory ◽  
Dalia A. El-Dib

The VHDL design and Field Programmable Gate Array (FPGA) implementation of a fuzzy control system to control the blood glucose level continuously based on current and previous values are presented. The design is based on simple models of the dynamic behavior of the glucose insulin system suitable for real-time control. The system is successfully implemented on FPGA promising efficient hardware implementation to be included in a low power, robust and reliable closed loop health monitoring system.


2019 ◽  
pp. 52-56
Author(s):  
Yu.F. Glukhov ◽  
N.V. Krutikov ◽  
A.V. Ivanov ◽  
N.P. Muravskaya

We have studied and analyzed status and metrological supervision of blood glucose monitors, individual devices for a person’s blood glucose level measurement. It has been indicated that nowadays blood glucose monitors like other individual devices for medical measurement are not allowed to be involved in telemedicine public service. This accounts for absence of metrological supervision with these measurement devices in telemedicine. In addition, the key problem is absence of safe methods and means of remote verificaition, calibration and transmission of measurement data to health care centers. The article offers a remote test method for blood glucose monitors using a number of resistors with values correlating with measured blood glucose level. The available method has been successfully trialed in real practice.


2010 ◽  
Vol 5 (2) ◽  
pp. 87
Author(s):  
Rusman Efendi ◽  
Evy Damayanthi ◽  
Lilik Kustiyah ◽  
Nastiti Kusumorini

<p class="MsoNormal" style="margin: 0cm 7.1pt 6pt 14.2pt; text-align: justify; text-indent: 1cm;"><span style="font-size: 10pt;">Diabetes mellitus is degeneratif disease with high prevalence that happens in many countries. Several studies had been done to control diabetes by using green tea, mullberry leaf  tea, and their mixture. The aim of this research was to analyze the influence of the administration green tea, mullbery leaf tea, and their mixtures to blood glucose level of diabetic rats both during 120 minutes after administration. This research had four phases, first to determine the best mullberry leaf tea, second to fourth phases respectively, determine turnover of blood glucose level on normal rats; attempt during 120 minutes on diabetic rats.  The result of research during 120 minutes have showed that blood glucose level on diabetic rats which were administered by green tea, mullberry leaf tea and their mixture is significantly difference with diabetic rats which were administered by water. Blood glucose level at baseline increased at 30<sup>th </sup>minutes and showed the difference significantly and then until 60<sup>th</sup> and 120<sup>th</sup> minutes and relatively stable. During 120 minutes after feed consumption, inhibition of blood glucose level occured increasingly on diabetic rats which were administered by green tea, mullberry leaf tea, and their mixture compared to diabetic rats which were administered by water.</span></p>


2020 ◽  
Vol 11 (4) ◽  
pp. 5067-5070
Author(s):  
Pang Jyh Chayng ◽  
Nurul Ain ◽  
Kaswandi Md Ambia ◽  
Rahim Md Noah

The purpose of this project is to study the anti-diabetic effect of on a diabetic rat model. A total of Twenty male Sprague rats were used and it randomly distributed into four groups which are Group I: , Group II: negative control, Group III: and Group IV: and . In diabetic model were induced with via injection at the dosage of 65mg/kg. and FBG (Fasting Blood Glucose) level of diabetic rats were assessed every three days. Blood was collected via cardiac puncture at day 21 after the induction of treatment. Insulin level of the rats was assessed with the Mercodia Rat Insulin ELISA kit. FBG level of group I (12.16 ±3.96, p&lt;0.05) and group IV (11.34 ±3.67, p&lt;0.05) were significantly decreased. Meanwhile, the for all rats did not show any significant increase. However, the insulin level was escalated in group IV (0.74+0.25, p&lt;0.05) significantly. The present study shows that the and the combination of and lowered blood glucose level and enhanced insulin secretion.


Author(s):  
Adel M. Aly ◽  
Ahmed S. Ali

: Glipizide (GZ) is an oral blood-glucose-lowering drug of the sulfonylurea class characterized by its poor aqueous solubility. Aiming for the production of GZ tablets with rapid onset of action followed by prolonged effect; GZ-Polyethylene glycol (PEG 4000 and 6000) solid dispersions with different ratios, (using melting and solvent evaporation method), as well as, coprecipitate containing GZ with polymethyl-methacrylate (PMMA) were prepared. Four tablet formulations were prepared containing; a) GZ alone, b) GZ: PEG6000, 1:10, c) GZ:PMMA 1:3, and, d)both GZ:PEG6000 1:10 and GZ:PMMA 1:3. The solvent evaporation method showed more enhancement of GZ solubility than the melting one, and this solubilizing effect increased with PEG increment. Generally, PEG6000 showed more enhancement of dissolution than PEG4000 especially at 1:10 drug: polymer ratio (the most enhancing formula). Also, the prepared tablet formulations showed acceptable physical properties according to USP/NF requirements. The dissolution results revealed that tablets containing PEG6000 (1:10) have the most rapid release rate, followed by the formula containing both PEG6000 and PMMA, while that including PMMA alone showed the slowest dissolution rate. Moreover, In-vivo studies for each of the above four formulations, were performed using four mice groups. The most effective formula in decreasing the blood glucose level, through the first 6 hours, was that containing GZ and PEG6000, 1:10. However, formula containing the combination of enhanced and sustained GZ was the most effective in decreasing the blood glucose level through 16 hours. Successful in-vitro in-vivo correlations could be detected between the percent released and the percent decreasing of blood glucose level after 0.5 hours.


Sign in / Sign up

Export Citation Format

Share Document