Inactivation of E. Coli affected by medium conductivity in pulsed electric field

Author(s):  
Tanya Kirilova Gachovska ◽  
Jeyamkondan Subbiah ◽  
Harshavardhan Thippareddi ◽  
David Marx ◽  
Frazer Williams
Author(s):  
Tanya Kirilova Gachovska ◽  
Jeyamkondan Subbiah ◽  
Harshavardhan Thippareddi ◽  
David Marx ◽  
Frazer Williams

2003 ◽  
Vol 217 (5) ◽  
pp. 434-437 ◽  
Author(s):  
B. Sen Gupta ◽  
F. Masterson ◽  
T. R. A. Magee

2001 ◽  
Vol 64 (6) ◽  
pp. 777-782 ◽  
Author(s):  
RAGIP UNAL ◽  
JIN-GAB KIM ◽  
AHMED E. YOUSEF

Pulsed electric field (PEF) and ozone technologies are nonthermal processing methods with potential applications in the food industry. This research was performed to explore the potential synergy between ozone and PEF treatments against selected foodborne bacteria. Cells of Lactobacillus leichmannii ATCC 4797, Escherichia coli O157:H7 ATCC 35150, and Listeria monocytogenes Scott A were suspended in 0.1% NaCl and treated with ozone, PEF, and ozone plus PEF. Cells were treated with 0.25 to 1.00 μg of ozone per ml of cell suspension, PEF at 10 to 30 kV/cm, and selected combinations of ozone and PEF. Synergy between ozone and PEF varied with the treatment level and the bacterium treated. L. leichmannii treated with PEF (20 kV/cm) after exposure to 0.75 and 1.00 μg/ml of ozone was inactivated by 7.1 and 7.2 log10 CFU/ml, respectively; however, ozone at 0.75 and 1.00 μg/ml and PEF at 20 kV/cm inactivated 2.2, 3.6, and 1.3 log10 CFU/ml, respectively. Similarly, ozone at 0.5 and 0.75 μg/ml inactivated 0.5 and 1.8 log10 CFU/ml of E. coli, PEF at 15 kV/cm inactivated 1.8 log10 CFU/ml, and ozone at 0.5 and 0.75 μg/ml followed by PEF (15 kV/cm) inactivated 2.9 and 3.6 log10 CFU/ml, respectively. Populations of L. monocytogenes decreased 0.1, 0.5, 3.0, 3.9, and 0.8 log10 CFU/ml when treated with 0.25, 0.5, 0.75, and 1.0 μg/ml of ozone and PEF (15 kV/cm), respectively; however, when the bacterium was treated with 15 kV/cm, after exposure to 0.25, 0.5, and 0.75 μg/ml of ozone, 1.7, 2.0, and 3.9 log10 CFU/ml were killed, respectively. In conclusion, exposure of L. leichmannii, E. coli, and L. monocytogenes to ozone followed by the PEF treatment showed a synergistic bactericidal effect. This synergy was most apparent with mild doses of ozone against L. leichmannii.


PLoS ONE ◽  
2016 ◽  
Vol 11 (7) ◽  
pp. e0158739 ◽  
Author(s):  
Linying Liu ◽  
Zheng Mao ◽  
Jianhua Zhang ◽  
Na Liu ◽  
Qing Huo Liu

2003 ◽  
Vol 66 (5) ◽  
pp. 755-759 ◽  
Author(s):  
GULSUN AKDEMIR EVRENDILEK ◽  
Q. HOWARD ZHANG

This investigation was undertaken to study the inactivation of Escherichia coli O157:H7 by pulsed electric field (PEF) treatment and heat treatment after exposure to different stresses. E. coli O157:H7 cells exposed to different pHs (3.6, 5.2, and 7.0 for 6 h), different temperatures (4, 35, and 40°C for 6 h), and different pre-PEF treatments (10, 15, and 20 kV/cm) were treated with PEFs (20, 25, and 30 kV/cm) or heat (60°C for 3 min). The results of these experiments demonstrated that a pH of 3.6 and temperatures of 4 and 40°C caused significant decreases in the inactivation of E. coli O157:H7 by PEF treatment and heat treatment (P < 0.05). Pre-PEF treatments, pHs of 5.2 and 7.0, and a temperature of 35°C, on the other hand, did not result in any resistance of E. coli O157:H7 cells to inactivation by PEF treatment and heat treatment (P > 0.05).


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1938
Author(s):  
Xiaojun Liu ◽  
Thomas Lendormi ◽  
Jean-Louis Lanoisellé

Animal by-products (ABP) can be valorized via anaerobic digestion (AD) for biogas energy generation. The digestate issued from AD process is usually used to fertilize farming land for agricultural activities, which may cause potential sanitary risk to the environment. The European Union (EU) requires that certain ABP be thermally pasteurized in order to minimize this sanitary risk. This process is called hygienization, which can be replaced by alternative nonthermal technologies like pulsed electric field (PEF). In the present study, Enterococcus faecalis ATCC 19433 and Escherichia coli ATCC 25922 were used as indicator bacteria. Their resistance to thermal pasteurization and PEF treatment were characterized. Results show that Ent. faecalis and E. coli are reduced by 5 log10 in less than 1 min during thermal pasteurization at 70 °C. The critical electric field strength was estimated at 18 kV∙cm−1 for Ent. faecalis and 1 kV∙cm−1 for E. coli. “G+” bacteria Ent. faecalis are generally more resistant than “G-” bacteria E. coli. AD process also plays an important role in pathogens inactivation, whose performance depends on the microorganisms considered, digestion temperature, residence time, and type of feedstock. Thermophilic digestion is usually more efficient in pathogens removal than mesophilic digestion.


2013 ◽  
Vol 133 (2) ◽  
pp. 32-37 ◽  
Author(s):  
Akira Nakagawa ◽  
Hitoshi Hatayama ◽  
Koichi Takaki ◽  
Shoji Koide ◽  
Yukio Kawamura

Sign in / Sign up

Export Citation Format

Share Document