Non-invasive assessment of temperature variation in Ex-vivo renal tissue by tracking average grey-level from B-mode images

Author(s):  
Andre Victor Alvarenga ◽  
Cesar A. D. Teixeira ◽  
M.A. von Kruger ◽  
W.C.A. Pereira
2021 ◽  
Vol 108 (Supplement_3) ◽  
Author(s):  
J Bote ◽  
J F Ortega-Morán ◽  
C L Saratxaga ◽  
B Pagador ◽  
A Picón ◽  
...  

Abstract INTRODUCTION New non-invasive technologies for improving early diagnosis of colorectal cancer (CRC) are demanded by clinicians. Optical Coherence Tomography (OCT) provides sub-surface structural information and offers diagnosis capabilities of colon polyps, further improved by machine learning methods. Databases of OCT images are necessary to facilitate algorithms development and testing. MATERIALS AND METHODS A database has been acquired from rat colonic samples with a Thorlabs OCT system with 930nm centre wavelength that provides 1.2KHz A-scan rate, 7μm axial resolution in air, 4μm lateral resolution, 1.7mm imaging depth in air, 6mm x 6mm FOV, and 107dB sensitivity. The colon from anaesthetised animals has been excised and samples have been extracted and preserved for ex-vivo analysis with the OCT equipment. RESULTS This database consists of OCT 3D volumes (C-scans) and 2D images (B-scans) of murine samples from: 1) healthy tissue, for ground-truth comparison (18 samples; 66 C-scans; 17,478 B-scans); 2) hyperplastic polyps, obtained from an induced colorectal hyperplastic murine model (47 samples; 153 C-scans; 42,450 B-scans); 3) neoplastic polyps (adenomatous and adenocarcinomatous), obtained from clinically validated Pirc F344/NTac-Apcam1137 rat model (232 samples; 564 C-scans; 158,557 B-scans); and 4) unknown tissue (polyp adjacent, presumably healthy) (98 samples; 157 C-scans; 42,070 B-scans). CONCLUSIONS A novel extensive ex-vivo OCT database of murine CRC model has been obtained and will be openly published for the research community. It can be used for classification/segmentation machine learning methods, for correlation between OCT features and histopathological structures, and for developing new non-invasive in-situ methods of diagnosis of colorectal cancer.


Antioxidants ◽  
2021 ◽  
Vol 10 (3) ◽  
pp. 414
Author(s):  
Alain Menzel ◽  
Hanen Samouda ◽  
Francois Dohet ◽  
Suva Loap ◽  
Mohammed S. Ellulu ◽  
...  

Many chronic conditions such as cancer, chronic obstructive pulmonary disease, type-2 diabetes, obesity, peripheral/coronary artery disease and auto-immune diseases are associated with low-grade inflammation. Closely related to inflammation is oxidative stress (OS), which can be either causal or secondary to inflammation. While a low level of OS is physiological, chronically increased OS is deleterious. Therefore, valid biomarkers of these signalling pathways may enable detection and following progression of OS/inflammation as well as to evaluate treatment efficacy. Such biomarkers should be stable and obtainable through non-invasive methods and their determination should be affordable and easy. The most frequently used inflammatory markers include acute-phase proteins, essentially CRP, serum amyloid A, fibrinogen and procalcitonin, and cytokines, predominantly TNFα, interleukins 1β, 6, 8, 10 and 12 and their receptors and IFNγ. Some cytokines appear to be disease-specific. Conversely, OS—being ubiquitous—and its biomarkers appear less disease or tissue-specific. These include lipid peroxidation products, e.g., F2-isoprostanes and malondialdehyde, DNA breakdown products (e.g., 8-OH-dG), protein adducts (e.g., carbonylated proteins), or antioxidant status. More novel markers include also –omics related ones, as well as non-invasive, questionnaire-based measures, such as the dietary inflammatory-index (DII), but their link to biological responses may be variable. Nevertheless, many of these markers have been clearly related to a number of diseases. However, their use in clinical practice is often limited, due to lacking analytical or clinical validation, or technical challenges. In this review, we strive to highlight frequently employed and useful markers of inflammation-related OS, including novel promising markers.


2019 ◽  
Vol 21 (Supplement_4) ◽  
pp. iv6-iv6
Author(s):  
Daniele Baiz ◽  
Caterina Negroni ◽  
Emanuela Ercolano ◽  
Claire L Adams ◽  
Kathreena M Kurian ◽  
...  

Abstract Introduction Meningioma brain tumours are the most common primary tumour in adults. Despite surgery and/or radiation therapy, meningioma may recur. The 5-year recurrence rate in benign meningioma is estimated in about 10% while much greater in atypical and malignant tumours. MicroRNAs (miRNAs) represent a large class of small RNAs driving regulation of gene expression and playing a role in tumour progression and therefore proposed as diagnostic tools. Moreover, miRNAs can be released from tumour cells into the blood stream via exosomes, showing potential to be used as liquid biopsies. Methods Identification of novel circulating biomarkers was conducted by performing an unbiased Cancer MicroRNA qPCR Array, followed by bioinformatics analysis. In parallel, we conducted a biased in silico analysis of the miRNAs targeting Cyclin D1 and E1, recently proposed as immunohistochemical meningioma biomarkers. Validation studies performed using TaqMan® reagents. Results Stringent unbiased (p<0.01) miRNA profiling followed by validation in ex vivo samples revealed that the miR-9-1 is upregulated in higher-grade meningioma tissues and serum exosomes, controlled by the EGFR/AP-1 axis and correlated with lower levels of E-Cadherin, a proposed biomarker for malignant meningioma. On the contrary, biased analysis, followed by validation in vitro and ex vivo, showed that the miR-497~195 cluster is downregulated in higher-grade meningioma tissues and serum exosomes, correlating with the overexpression of GATA-4, a novel meningioma tissue biomarker. Conclusion Our data demonstrated that both miR-497~195 and miR-9-1 show potential to become promising non-invasive biomarkers for higher-grade meningioma, reflecting their expression status in tissues. (DB and CN contributed equally).


2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
A. Shoemark ◽  
R. Wilson

Bronchiectasis is characterised by neutrophilic bronchial inflammation. Direct measurement of lung inflammation would be useful to assess disease activity, guide need for treatment, and monitor response. The aim of this study was to test whether exhaled breath condensate (EBC) pH, a simple noninvasive test, provides a clinically useful measure of inflammation in the lungs of patients with bronchiectasis. 96 consecutively referred patients were studied when clinically stable, 20 followed up over two years, and a further 22 patients seen during an exacerbation. Subjects breathed tidally for 10 minutes into a condensing chamber (Ecoscreen, Erich Jaeger, Hoechberg, Germany). pH in EBC was measured immediately using a pH probe. In a representative group of 25 patients samples were deaerated with argon gas. This was to control for variations in pH ex vivo by removing CO2. EBC was acidic in bronchiectasis patients () compared to controls () and primary ciliary dyskinesia patients (). pH was related to lung volume but not disease severity. Repeated measures show EBC pH changes with symptoms. EBC is further acidified during an exacerbation of bronchiectasis (), this acidification persists following treatment (). EBC pH is not sufficiently sensitive or specific to monitor patients' health status or provide information to inform acute treatment decisions.


2019 ◽  
Vol 2 (1) ◽  
Author(s):  
Emilia V. Silletta ◽  
Alexej Jerschow ◽  
Guillaume Madelin ◽  
Leeor Alon

AbstractNon-invasive measurement of absolute temperature is important for proper characterization of various pathologies and for evaluation of thermal dose during interventional procedures. The proton (hydrogen nucleus) magnetic resonance (MR) frequency shift method can be used to map relative temperature changes. However, spatiotemporal variations in the main magnetic field and the lack of local internal frequency reference challenge the determination of absolute temperature. Here, we introduce a multinuclear method for absolute MR thermometry, based on the fact that the hydrogen and sodium nuclei exhibit a unique and distinct characteristic frequency dependence with temperature and with electrolyte concentration. A one-to-one mapping between the precession frequency difference of the two nuclei and absolute temperature is demonstrated. Proof-of-concept experiments were conducted in aqueous solutions with different NaCl concentrations, in agarose gel samples, and in freshly excised ex vivo mouse tissues. One-dimensional chemical shift imaging experiments also demonstrated excellent agreement with infrared measurements.


2020 ◽  
Vol 56 (4) ◽  
pp. 522-531 ◽  
Author(s):  
D. Basurto ◽  
N. Sananès ◽  
E. Verbeken ◽  
D. Sharma ◽  
E. Corno ◽  
...  

2019 ◽  
Vol 47 (5) ◽  
pp. 1302-1313 ◽  
Author(s):  
Camilla Christensen ◽  
Lotte K. Kristensen ◽  
Maria Z. Alfsen ◽  
Carsten H. Nielsen ◽  
Andreas Kjaer

Abstract Purpose Despite remarkable clinical responses and prolonged survival across several cancers, not all patients benefit from PD-1/PD-L1 immune checkpoint blockade. Accordingly, assessment of tumour PD-L1 expression by immunohistochemistry (IHC) is increasingly applied to guide patient selection, therapeutic monitoring, and improve overall response rates. However, tissue-based methods are invasive and prone to sampling error. We therefore developed a PET radiotracer to specifically detect PD-L1 expression in a non-invasive manner, which could be of diagnostic and predictive value. Methods Anti-PD-L1 (clone 6E11, Genentech) was site-specifically conjugated with DIBO-DFO and radiolabelled with 89Zr (89Zr-DFO-6E11). 89Zr-DFO-6E11 was optimized in vivo by longitudinal PET imaging and dose escalation with excess unlabelled 6E11 in HCC827 tumour-bearing mice. Specificity of 89Zr-DFO-6E11 was evaluated in NSCLC xenografts and syngeneic tumour models with different levels of PD-L1 expression. In vivo imaging data was supported by ex vivo biodistribution, flow cytometry, and IHC. To evaluate the predictive value of 89Zr-DFO-6E11 PET imaging, CT26 tumour-bearing mice were subjected to external radiation therapy (XRT) in combination with PD-L1 blockade. Results 89Zr-DFO-6E11 was successfully labelled with a high radiochemical purity. The HCC827 tumours and lymphoid tissue were identified by 89Zr-DFO-6E11 PET imaging, and co-injection with 6E11 increased the relative tumour uptake and decreased the splenic uptake. 89Zr-DFO-6E11 detected the differences in PD-L1 expression among tumour models as evaluated by ex vivo methods. 89Zr-DFO-6E11 quantified the increase in PD-L1 expression in tumours and spleens of irradiated mice. XRT and anti-PD-L1 therapy effectively inhibited tumour growth in CT26 tumour-bearing mice (p < 0.01), and the maximum 89Zr-DFO-6E11 tumour-to-muscle ratio correlated with response to therapy (p = 0.0252). Conclusion PET imaging with 89Zr-DFO-6E11 is an attractive approach for specific, non-invasive, whole-body visualization of PD-L1 expression. PD-L1 expression can be modulated by radiotherapy regimens and 89Zr-DFO-6E11 PET is able to monitor these changes and predict the response to therapy in an immunocompetent tumour model.


2019 ◽  
Vol 133 (2) ◽  
pp. 87-94 ◽  
Author(s):  
R Schuon ◽  
B Mrevlje ◽  
B Vollmar ◽  
T Lenarz ◽  
G Paasche

AbstractObjectivesThe cause of Eustachian tube dysfunction often remains unclear. Therefore, this study aimed to examine the feasibility and possible diagnostic use of optical coherence tomography in the Eustachian tube ex vivo.MethodsTwo female blackface sheep cadaver heads were examined bilaterally. Three conditions of the Eustachian tube were investigated: closed (resting position), actively opened and stented. The findings were compared (and correlated) with segmented histological cross-sections.ResultsIntraluminal placement of the Eustachian tube with the optical coherence tomography catheter was performed without difficulty. Regarding the limited infiltration depth of optical coherence tomography, tissues can be differentiated. The localisation of the stent was accurate as was the lumen.ConclusionThe application of optical coherence tomography in the Eustachian tube under these experimental conditions is considered to be a feasible, rapid and non-invasive diagnostic method, with possible diagnostic value for determining the luminal shape and superficial lining tissue of the Eustachian tube.


Sign in / Sign up

Export Citation Format

Share Document