scholarly journals EAO‐483/PO‐PIB‐015 | Reliability and correlation of different implant stability devices: RFA versus Insertion Torque.

2021 ◽  
Vol 32 (S22) ◽  
pp. 128-129
Author(s):  
Ingrid Kästel ◽  
Giles de Quincey ◽  
Jörg Neugebauer ◽  
Robert Sader ◽  
Peter Gehrke

Abstract Background There is disagreement about the optimal torque for tightening smartpegs for resonance frequency analysis (RFA). Subjective finger pressure during hand tightening could affect the reliability of the resulting values. The aim of the current study was therefore to assess whether or not the insertion torque of a smartpeg magnetic device influences the implant stability quotient (ISQ) value during RFA. Methods Thirty self-tapping screw implants (XiVE S, Dentsply Sirona Implants, Bensheim, Germany) with a diameter of 3.8 mm and a length of 11 mm were inserted in three cow ribs with a bone quality of D1. The RFA value of each implant was measured (Ostell, FA W&H Dentalwerk, Bürmoos, Austria) in two orthogonal directions (mesial and buccal) after tightening the corresponding smartpeg type 45 with a mechanically defined value of 5 Ncm (Meg Torq device, Megagen, Daegu, South Korea) (test). Additionally, 4 different examiners measured the RFA after hand tightening the smartpegs, and the results were compared (control). Insertion torque values were determined by measuring the unscrew torque of hand seated smartpegs (Tohnichi Manufacturing Co. Ltd, Tokyo, Japan). Results The ISQ values varied from 2 to 11 Ncm by hand tightening and from 2 to 6 Ncm by machine tightening. The comparison of hand and machine tightening of smartpegs displayed only minor differences in the mean ISQ values with low standard deviations (mesial 79.76 ± 2,11, buccal 77.98 ± 2,) and no statistical difference (mesial p = 0,343 and buccal p = 0,890). Conclusions Manual tightening of smartpeg transducers allows for an objective and reliable determination of ISQ values during RFA.


2019 ◽  
Vol 2019 ◽  
pp. 1-4 ◽  
Author(s):  
Antonio Scarano ◽  
Bartolomeo Assenza ◽  
Francesco Inchingolo ◽  
Filiberto Mastrangelo ◽  
Felice Lorusso

Background. The immediate placement of a dental implant could represent an option treatment for the rehabilitation of a postextractive missing tooth socket to replace compromised or untreatable teeth, with the advantage of single-session surgery. In this way, the anatomy of the alveolar bone defect, the preservation of the buccal cortical bone, and the primary stability of the fixture represent the critical factors that consent a precise implant placement. Objective. This case report describes a novel fixture design for postextractive alveolar socket immediate implant. Methods. Two patients (25 and 31 years old) were treated for postextractive dental implant placement to replace both central upper incisor teeth with four implants. The residual bone implant gap was not filled with graft or bone substitute. The restoration was provided following a standard loading protocol by a cement-sealed prosthetic abutment. Results. Clinically, all implants positioned showed an excellent insertion torque. No postoperative complications were reported. At 6 months of healing, the buccal cortical bone and the implant stability were present and well maintained. Conclusion. The evidence of this study allows us to underline the possible advantages of this new fixture design for postextractive implant technique.


2019 ◽  
Vol 2019 ◽  
pp. 1-14 ◽  
Author(s):  
Fernanda Faot ◽  
Amália Machado Bielemann ◽  
Alessandra Julie Schuster ◽  
Raissa Micaella Marcello-Machado ◽  
Altair Antoninha Del Bel Cury ◽  
...  

Aim. To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. Methods. Thirty-one edentulous patients received two narrow implants (2.9x10mm, Facility NeoPoros) to retain mandibular overdentures. The implants were categorized in four groups according to their IT: (G1) IT > 10 Ncm; (G2) IT ≥ 10Ncm and ≤ 30 Ncm; (G3) IT >30Ncm and < 45Ncm; (G4) IT ≥ 45Ncm, and all implants were loaded after 3 months of healing. The following clinical outcomes were evaluated 1, 3, 6, and 12 months after implant insertion: (i) peri-implant tissue health (PH), gingival index (GI), plaque index (PI), calculus presence (CP), probing depth (PD), and bleeding on probing (BOP); (ii) implant stability quotient (ISQ) by resonance frequency analysis; and (iii) IL-1β and TNF-α concentration in the peri-implant crevicular fluid. The marginal bone level (MBL) and changes (MBC) were evaluated. The Chi2 test, Kruskal-Wallis test, mixed-effects regression analysis, and the Kendall rank correlation coefficient were used for statistical analysis (α = 5%). Results. G1 presented the highest PD at all evaluated periods. G2 presented higher PI at month 6 and 12. G4 showed increased GI at month 3 and 12 and more CP at month 1 (p=.003). G2 and G4 had higher ISQ values over the study period, while those from G1 and G3 presented lower ISQ values. The IL-1β concentration increased until month 12 and was independent of IT and bone type; G4 had a higher IL-1β concentration in month 3 than the other groups (p=.015). The TNF-α release was negatively correlated with IT, and TNF-α release was highest in G1 at month 12. The MBL immediately after surgery and the MBC at month 12 were similar between the groups, and G4 presented a positive MBC at month 12. The survival and success rates were 75% for G1, 81.3% for G2, 64.3% for G3, and 95% for G4. Conclusion. The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm.


2015 ◽  
Vol 812 ◽  
pp. 233-238
Author(s):  
Dávid Pammer ◽  
Eszter Bognár

The aim of this research is to develop a new minimally invasive measurement procedure. With this method implantologist could determine the local mechanical and structural properties of the cellular solids materials (e.g. bones) into which implants are placed. The currently applied methods are based on image measurement procedures (CT, Hounsfield scale etc.). The dentists, with the knowledge of the determined mechanical properties of the bone, can choose the ideal surgical parameters (flap size, diameter of drill, hole-depth, healing time, etc.) and the ideal implant type for the patients. During the development of the measuring procedure, was used bone modeling materials (“bone-like materials”) instead of bone. With these materials it is easier to do tests, than with living tissues. The bone like materials needs to have the same mechanical and structural properties as the given bone. The following bone like materials was used during the measurement: woods (Amaranth, Alnus, Ipe, Iroko, Robinia, Pyrus, Zebrano), and on the market available polyurethane solid foams (Sawbones D1 and D2). Among the literatures are summaries, which include the biomechanical assessments for implant stability. These technics are good to determine the implant stability in different bones and bone like materials after the implantation. In this work torsional test were used. This test is based on the determination of the insertion torque as a function of the implant displacement. Used the insertion torque functions and the screw geometrical parameters, the rotational work was determined. The different materials insertion torque functions have different slope values. The slopes and the rotational work results show which bone like material has similar insertion parameters (insertion torque function, rotational work) as a mandible during the insertion of an implant. With this torsional test and the knowledge of the bone like materials insertion torque functions and the rotational works it is possible to find the best material for the modeling of an implantation. Using this material, medical students can practice and improved the surgical techniques.


Materials ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2398 ◽  
Author(s):  
Christian Makary ◽  
Abdallah Menhall ◽  
Carole Zammarie ◽  
Teresa Lombardi ◽  
Seung Yeup Lee ◽  
...  

Background: Macro- and micro-geometry are among the factors influencing implant stability and potentially determining loading protocol. The purpose of this study was to test a protocol for early loading by controlling implant stability with the selection of fixtures with different thread depth according to the bone density of the implant site. Materials and Methods: Patients needing implant therapy for fixed prosthetic rehabilitation were treated by inserting fixtures with four different thread diameters, selected based on clinical assessment of bone quality at placement (D1, D2, D3, and D4, according to Misch classification). Final insertion torque (IT) and implant stability quotient (ISQ) were recorded at baseline and ISQ measurements repeated after one, two, three, and four weeks. At the three-week measurement (four weeks after implant replacement), implants with ISQ > 70 Ncm were functionally loaded with provisional restorations. Marginal bone level was radiographically measured 12 months after implant insertion. Results: Fourteen patients were treated with the insertion of forty implants: Among them, 39 implants showing ISQ > 70 after 3 weeks of healing were loaded with provisional restoration. Mean IT value was 82.3 ± 33.2 Ncm and varied between the four different types of bone (107.2 ± 35.6 Ncm, 74.7 ± 14.0 Ncm, 76.5 ± 31.1 Ncm, and 55.2 ± 22.6 Ncm in D1, D2, D3, and D4 bone, respectively). Results showed significant differences except between D2 and D3 bone types. Mean ISQ at baseline was 79.3 ± 4.3 and values in D1, D2, D3, and D4 bone were 81.9 ± 2.0, 81.1 ± 1.0, 78.3 ± 3.7, and 73.2 ± 4.9, respectively. Results showed significant differences except between D1 and D2 bone types. IT and ISQ showed a significant positive correlation when analyzing the entire sample (p = 0.0002) and D4 bone type (p = 0.0008). The correlation between IT and ISQ was not significant when considering D1, D2, and D3 types (p = 0.28; p = 0.31; p = 0.16, respectively). ISQ values showed a slight drop at three weeks for D1, D2, and D3 bone while remaining almost unchanged in D4 bone. At 12-month follow-up, all implants (39 early loading, 1 conventional loading) had satisfactory function, showing an average marginal bone loss of 0.12 ± 0.12 mm, when compared to baseline levels. Conclusion: Matching implant macro-geometry to bone density can lead to adequate implant stability both in hard and soft bone. High primary stability and limited implant stability loss during the first month of healing could allow the application of early loading protocols with predictable clinical outcomes.


Author(s):  
Bernardo Ferreira Lemos ◽  
Paula Lopez-Jarana ◽  
Carlos Falcao ◽  
Blanca Ríos-Carrasco ◽  
Javier Gil ◽  
...  

As immediate loading protocols are becoming more frequent, the primary stability of implants has become an essential criterion for the osseointegration of dental implants. Based on this, the objective of this study was to understand the influence of different undersized surgical preparation sites on the insertion torque (IT) and implant stability quotient (ISQ). Four different site-preparation protocols were performed on fresh humid type III bovine bone: one control, the standard protocol recommended by the manufacturer (P1), and three variations of undersized techniques (P2, P3 and P4). The implant used was VEGA by Klockner Implant System. The sample size was n = 40 for each of the four groups. A torquemeter was used to measure the IT, and the ISQ was measured with a Penguin RFA. Both variables showed a tendency to increase as the preparation technique was reduced, although not all the values were statistically significant (p < 0.05) when comparing with the standard preparation. The preparations without a cortical drill, P2 and P4, showed better results than those with a cortical drill. Given the limitations of this study, it can be concluded that reducing the implant preparation can increase both the IT and ISQ. Removing the cortical drill is an effective method for increasing implant stability, although it should be used carefully.


2016 ◽  
Vol 42 (1) ◽  
pp. 17-25 ◽  
Author(s):  
David E. Simmons ◽  
Archontia Palaiologou ◽  
Austin G. Teitelbaum ◽  
Susan Billiot ◽  
Lomesh J. Popat ◽  
...  

This investigation was undertaken to determine if multithreaded implants partially coated with plasma-sprayed hydroxyapatite (HA) could be effectively loaded earlier than 3–6 months after placement. Forty-eight patients (22 men, 26 women) were enrolled in the study and received 48 implants. The population was divided into 2 groups: A implants (n = 23) were loaded immediately on the day of surgery and group B implants (n = 19) were loaded 3 weeks after surgery. Cone beam computerized tomography (CBCT) scans were taken preoperatively to aid in treatment planning. Bone density was evaluated by tactile feedback during surgery. Insertion torque was recorded at time of implant placement. Resonance frequency analysis, performed on the day of surgery, at the time of loading, and at 6, 12, and 24 months, was used to record implant stability according to the unit's implant stability quotient (Osstell ISQ). Standardized radiographs were taken at time of implant placement and at 6, 12, and 24 months to measure crestal bone stability. Bone level changes were measured by software (Image J). Bone quality was judged as either type 1 (n = 1), 2 (n = 31), 3 (n = 15), or 4 (n = 1). There were no failures in the group A (survival = 100%, n = 23/23) and 1 failure in group B (survival = 94.7%, n = 18/19). After 2 years in function, cumulative mean radiographic bone loss was 0.75 ± 0.50mm (maxillae: 0.92 ± 0.49 mm, n = 14; mandibles: 0.67 ± 0.49 mm, n = 28). No differences in bone levels were noted between implants placed in previously augmented and nonaugmented sites, and there were no periodontal or soft tissue complications. After 2 years in function, implants partially coated with plasma-sprayed and hydrothermally treated HA were clinically predictable when restored in occlusion immediately after or within 3 weeks of implant placement.