Distribution of nanoparticles in the anterior chamber of porcine eyes

2019 ◽  
Vol 97 (S263) ◽  
Author(s):  
Tobias Sonntag ◽  
Franziska Froemel ◽  
Michaela Guter ◽  
Andrea Dillinger ◽  
Rudolph Fuchshofer ◽  
...  
2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Hisaharu Suzuki ◽  
Tsutomu Igarashi ◽  
Toshihiko Shiwa ◽  
Hiroshi Takahashi

Due to recent technical advances in cataract surgeries, there has been a significant improvement in the safety and surgical outcomes of phacoemulsification. However, the corneal endothelium can be damaged during phacoemulsification by multiple factors. Therefore, we used a slit lamp to analyze the fluid dynamics of ophthalmic viscosurgical devices (OVDs) in the anterior chamber during phacoemulsification. In this experimental study, extracted porcine eyes were injected with OVDs stained with fluorescein through a side port of the eye and then fixed on a slit lamp microscope. After inserting a phaco tip, phacoemulsification simulation was then performed on the iris plane. Subsequent movements of OVDs in the anterior chamber were observed during the procedure by using a slit lamp microscope. Aspiration and removal of cohesive OVDs from the inside of the anterior chamber occurred within a few seconds after the ultrasonic vibration. Aspiration of dispersive OVDs occurred gradually, with some of the OVDs remaining on the side of the anterior chamber side in an irregular shape. This shape enabled the OVD to trap the air, thereby preventing the air from directly touching the corneal endothelium. Viscoadaptive OVDs remained inside the anterior chamber as a lump, with the infusion solution flowing between the corneal endothelium and the OVD, thus leading to the eventual aspiration of the OVD. Viscous dispersive OVDs remained as a lump between the corneal endothelium and the phaco tip. However, once the infusion solution flowed between the cornea and the OVD, the OVD detached from the corneal endothelium, indicating that this type would likely be aspirated and removed. This method, termed the “slit side view,” enables viewing of the movement of OVDs during surgery, as well as observation of the fluid dynamics in the anterior chamber.


2017 ◽  
Author(s):  
Chao Wang ◽  
Yalong Dang ◽  
Susannah Waxman ◽  
Nils A Loewen

Purpose: To compare the intraoperative angle stability and the postoperative outflow of two ab interno trabeculectomy devices that excise the trabecular meshwork. The newer device has an active aspiration and irrigation port while the older requires viscoelastic to maintain the anterior chamber. We hypothesized that anterior segment optical coherence tomography (ASOCT) allows quantifying the intraoperative behavior in a microincisional glaucoma surgery (MIGS) pig eye training model. Methods: Twelve freshly enucleated porcine eyes were measured with ASOCT at baseline, at the beginning of the procedure and at its conclusion to determine the anterior chamber depth (ACD) and the nasal angle


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Koji Nagae ◽  
Hiromasa Sawamura ◽  
Makoto Aihara

AbstractTo evaluate a new method of measuring the intraocular pressure (IOP) in the vitreous cavity. IOPs in the anterior chamber and vitreous cavities of 24 porcine eyes (12 eyes with lenses and 12 eyes without lenses) were measured directly, continuously, and simultaneously. We used a needle as a part of the pressure sensor to measure the anterior chamber IOP and a disk-shaped sensor to measure the vitreous cavity IOP. A significant group-by-condition interaction on the vitreous cavity IOP between the two groups (phakia and aphakia) and four conditions of anterior chamber IOP were observed (F[3,258] = 5.8564, p < 0.001). A positive correlation was observed between the vitreous cavity IOP and anterior chamber IOP in both the phakia group (R = 0.96, p < 0.001) and the aphakia group (R = 0.97, p < 0.001). No significant correlation was observed between the ΔIOPv-a (vitreous cavity IOP − anterior chamber IOP) and anterior chamber IOP in either group (phakia group: R =  − 0.18, p = 0.034; aphakia group: R =  − 0.029, p = 0.73). The vitreous cavity IOP measured with the new sensor was well-correlated with the anterior chamber IOP in the physiological range tested.


2008 ◽  
Vol 225 (S 1) ◽  
Author(s):  
Z Bíró ◽  
T Kerek ◽  
K Aranyoss ◽  
P Gyaki

2018 ◽  
Vol 1 ◽  
pp. 3
Author(s):  
Joshua S Agranat ◽  
Yoshihiro Yonekawa

Iris pigment epithelial (IPE) cysts are a subset of iris cysts that arise from the IPE. They are spontaneously erupting epithelial-lined cavities that are found in various anatomic locations of the iris, including the iris pupillary margin, midzone, periphery, and free floating in the vitreous or anterior chamber. We report the case of an asymptomatic 13-year-old boy with an incidental finding of a dislodged anterior chamber cyst diagnosed on routine examination. Modern multimodal image analysis of the cyst including anterior segment optical coherence tomography and ultrasound biomicroscopy (UBM) was utilized to characterize the microstructural anatomy of the lesion. The patient was managed conservatively without complications. Cysts of the IPE typically do not affect vision or ocular health and can be monitored and observed after ascertaining no associated malignancy. Initial diagnostic investigation can include UBM and anterior segment optical coherence tomography. Intervention should be reserved only for cases where the cyst growth leads to obstruction of the visual axis and/or other secondary complications.


Author(s):  
V.S. Shevchenko ◽  
◽  
A.S. Prilutskii ◽  
K.Y. Tkachenko ◽  
◽  
...  

Актуальность. Фактор некроза опухоли(TNF-α) является провоспалительным цитокином, продуцирующимся макрофагами и многими другими клетками. Данные о вариации концентрацииTNF-α во влаге передней камеры глаза у лиц, не имеющих выраженных воспалительных и аутоиммунных процессов практически единичны. Цель. Исследование диапазона вариации фактора некроза опухоли альфа во влаге передней камеры глаза у пациентов с возрастной катарактой. Материал и методы. Отобраны и обследованы 33 пациента, в возрасте от 47 до 82 лет, госпитализированных для плановой экстракции катаракты не имеющих выраженных сопутствующих воспалительных заболеваний (аутоиммунных, острых инфекционных болезней, обострением хронических заболеваний, глаукомы, перенесенного увеита и др.). Влага передней камеры забиралась при вскрытии передней камеры глаза во время факоэмульсификации катаракты. Исследование TNF-αпроводилось с помощью иммуноферментны хтест-систем, разработанных при участии сотрудников кафедры клинической иммунологии, аллергологии и эндокринологии ГОО ВПО «ДонНМУ им.М. Горького». Вышеуказанные тест-системы характеризует высокая чувствительность (0,5 пикограмм в миллилитре) и хорошая воспроизводимость. Результаты. При исследовании уровня TNF-αво влаге передней камеры глаза у пациентов с возрастной катарактой, мы выявили колебания данного показателя от 0 до 2,49 пкг/мл. Следует отметить, что полученные нами результаты показывают небольшую вариацию (в пределах низких значений) данного провоспалительного цитокина в исследованной жидкости у пациентов в возрасте от 47 до80 лет, не имеющих выраженной воспалительной(аутоиммунной и др.) патологии. Выводы. Показана низкая вариация TNF-α во влаге передней камеры глаза у пациентов с возрастной катарактой (у обследуемых исключена сопутствующая выраженная воспалительная патология). Результаты можно также использовать как контрольные при проведении сравнительныхисследований этого цитокина в данной среде у лицс различными заболеваниями глаза.


2019 ◽  
Vol 43 (1) ◽  
pp. 21-25
Author(s):  
Mohammed Senna Hassan

   Twenty Iraqi ducks hearts ( 10 male and 10 female ) have been  used for   demonstration  and illustration of heart's valves  and chambers  as well as  anatomical   and morphological site of view to explain what modifications had been take place for ducks heart  to perform  his normal life at the  circumstances  of  high  blood  pressure  and  pulse  rate. The heart  which has distinctly pointed  apex  was  built   in simple  manner located  in a transparent  taught  heart  pericardial  sac. It   was pyramidal in shape  externally  and  has a longitudinal  salcus  passing  to the  right  side, the  anterior of  the   heart  is  divided  into two  unequal  anterior  chamber  similar  to  those of mammalian  hear  .The heart valves are modified  in  order to  minimize  the  fraction  that occur as a result of  high  blood  pressure  and  pulse  rate  of  the  duck  heart , also  the  muscular  trabeculae   replace  the  chordate  tendineae  , which  were  present in the  mammalian    heart  in order to  minimize  the  fraction  resulting  from high  pulse  rate..    


Sign in / Sign up

Export Citation Format

Share Document