Leadless pacemaker implantation sites confirmed by computed tomography and their parameters and complication rates

Author(s):  
Hirofumi Arai ◽  
Akira Mizukami ◽  
Yoshihiro Hanyu ◽  
Takuya Kawakami ◽  
Yuki Shimizu ◽  
...  
Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
ivan mendoza ◽  
Jorge Penalver ◽  
Ninoska N Aranguibel ◽  
Chamorro Jose ◽  
Juan P zambrano ◽  
...  

Introduction: Transcatheter pacing systems have recently emerged as a safe and effective alternative in treating patients who require right ventricular pacing therapy. Traditionally, patients with atrial fibrillation with slow ventricular response had been benefit from this therapy. More recent, patients with symptomatic paroxysmal complete AV block had been receiving these devices. At this moment there is no data available about the feasibility , safety or outcomes of leadless pacemaker in this subgroup of patients Objective: The aim of this study was to assess the feasibility safety and 1 year follow up of the transcatheter leadless pacemaker device in patients with paroxysmal complete AV block . Methods: One hundred and ten (110 ) consecutive patients who underwent implantation of a Micra transcatheter leadless pacemaker (LPM)and have been follow up for at least a year were evaluated . Forty one (41) of these patients had the device implanted after experiencing symptomatic paroxysmal complete AV block. A t-test analysis was used to compare patient demographics, total procedure times, complication rates and recaptures necessary during the procedure. Results: All the patients with symptomatic paroxysmal complete AV block were implanted successfully with the leadless pacemaker system ( LPN ) . None of the patients suffered complications during the procedures. Fifty three percent ( 53%) were female , mean age of 77 , mean procedure time was 21.1 min. The mean number of recaptures required were 0.48 . None of the patient experienced pacemaker syndrome or progress to complete AV block after 1 year of follow up Conclusion: Leadless pacemaker implantation appears to be a safe and feasible alternative for subjects with symptomatic paroxysmal complete AV block . Further studies are required in these subgroup of patients


Respiration ◽  
2021 ◽  
pp. 1-9
Author(s):  
Kai-Lun Yu ◽  
Shun-Mao Yang ◽  
Huan-Jang Ko ◽  
Hui-Yu Tsai ◽  
Jen-Chung Ko ◽  
...  

<b><i>Background:</i></b> The diagnostic yield of peripheral pulmonary lesions (PPLs) using radial endobronchial ultrasound (EBUS) remains challenging without navigation systems. Cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) represents a recently developed technique, and its clinical utility remains to be investigated. <b><i>Objectives:</i></b> The aim of this study was to investigate the diagnostic yield of transbronchial biopsy (TBB) using a combination of CBCT-AF and radial EBUS. <b><i>Methods:</i></b> We recruited consecutive patients with PPLs who underwent radial EBUS-guided TBB, with or without AF, between October 2018 and July 2019. Following propensity score 1:1 matching, we recorded the procedure-related data and measured their efficacy and safety. <b><i>Results:</i></b> While 72 patients received EBUS-plus-AF, 235 patients received EBUS only. We included 53 paired patients following propensity score matching. The median size of lesions was 2.8 and 2.9 cm in the EBUS-plus-AF group and EBUS-only group, respectively. Diagnostic yield was higher in the former group (75.5 vs. 52.8%; <i>p</i> = 0.015). The diagnostic yield for the EBUS-plus-AF group was significantly higher for lesions ≤30 mm (73.5 vs. 36.1%; <i>p</i> = 0.002). Moreover, there was no significant difference in the complication rates (3.8 vs. 5.7%; <i>p</i> = 1.000). Twenty-four nodules (45.3%) were invisible by fluoroscopy in the EBUS-plus-AF group. All of them were identifiable on CBCT images and successfully annotated for AF. The mean radiation dose of total procedure, CBCT, and fluoroscopy was 19.59, 16.4, and 3.17 Gy cm<sup>2</sup>, respectively. <b><i>Conclusions:</i></b> TBB using a combination of CBCT-AF and EBUS resulted in a satisfactory diagnostic yield and safety.


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S204
Author(s):  
Ashwani Gupta ◽  
Muhammad Zubair Khan ◽  
Steven P. Kutalek

2021 ◽  
pp. 1-6
Author(s):  
Thomas Huang ◽  
Edward O’Leary ◽  
Mark E. Alexander ◽  
Laura Bevilacqua ◽  
Francis Fynn-Thompson ◽  
...  

Abstract Introduction: Reflex-mediated syncope occurs in 15% of children and young adults. In rare instances, pacemakers are required to treat syncopal episodes associated with transient sinus pauses or atrioventricular block. This study describes a single centre experience in the use of permanent pacemakers to treat syncope in children and young adults. Materials and methods: Patients with significant pre-syncope or syncope and pacemaker implantation from 1978 to 2018 were reviewed. Data collected included the age of presentation, method of diagnosis, underlying rhythm disturbance, age at implant, type of pacemaker implanted, procedural complications and subsequent symptoms. Results: Fifty patients were identified. Median age at time of the first syncopal episode was 10.2 (range 0.3–20.4) years, with a median implant age of 14.9 (0.9–34.3) years. Significant sinus bradycardia/pauses were the predominant reason for pacemaker implant (54%), followed by high-grade atrioventricular block (30%). Four (8%) patients had both sinus pauses and atrioventricular block documented. The majority of patients had dual-chamber pacemakers implanted (58%), followed by ventricular pacemakers (38%). Median follow-up was 6.7 (0.4–33.0) years. Post-implant, 4 (8%) patients continued to have syncope, 7 (14%) had complete resolution of their symptoms, and the remaining reported a decrease in their pre-syncopal episodes and no further syncope. Twelve (24%) patients had complications, including two infections and eight lead malfunctions. Conclusions: Paediatric patients with reflex-mediated syncope can be treated with pacing. Complication rates are high (24%); as such, permanent pacemakers should be reserved only for those in whom asystole from sinus pauses or atrioventricular block has been well documented.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Moghniuddin Mohammed ◽  
Amit Noheria ◽  
Seth Sheldon ◽  
Madhu Reddy

Introduction: There are no randomized controlled trials that compared the outcomes of leadless pacemaker (L-PPM) implantation with transvenous pacemaker (TV-PPM) and there is scarcity of data on real world outcomes. Methods: We queried National Inpatient Sample to identify all adult patients who had primary discharge diagnosis of conduction disorders or tachy-arrhythmias and excluded patients who had a concomitant procedure for valve replacement, coronary artery bypass grafting, ablation and/or cardiac implantable electronic device removal so that complications can be attributed to the pacemaker implantation. We included only procedures from November 2016 to December 2017 as Micra was the only available L-PPM during that period. For the comparison cohort we selected patients, during the same time period, who had a procedure code for single chamber pacemaker implantation in conjunction with right ventricular lead placement. We performed 1:1 propensity score matching and the variables used for matching are marked with asterisk in Table 1. All the codes used to identify complications has been previously validated from the Micra Post-approval registry and Coverage with Evidence Study. Results: Total of 1,305 patients for L-PPM and 13,905 patients in the TV-PPM group were included. Baseline characteristics with standardized mean difference before and after matching are shown in Table 1. Briefly, patients in L-PPM group were younger but had higher co-morbidities compared to TV-PPM group. The complications before and after matching are shown in Table 2. Conclusions: In conclusion, we found no significant difference between in-hospital complications after propensity score matching, with the exception of deep venous thrombosis. There was no difference between length of stay but cost for L-PPM was significantly higher. In this real-world analysis, we found that the leadless PPM implantation is safe in comparison to transvenous PPM.


2020 ◽  
Author(s):  
Jus Ksela ◽  
Mark Racman ◽  
Rok Zbacnik ◽  
Anze Djordjevic ◽  
Matevz Jan

Abstract Background: Pocket-related complications following the implantation of cardiovascular implantable electronic devices primarily include pocket hematoma, infection, skin erosion or decubitus, device migration, and Twiddler's syndrome, with other pathologies such as nerve impairment or bone lesions being extremely rarely encountered. We report a case of a 20-year old asthenic, non-athlete female patient presenting with a device-generated fracture of the second rib several months after sub-muscular permanent pacemaker implantation due to repeated bilateral pre-pectoral pocket infections.Case presentation: A 20-year old female patient was readmitted to our institution 9 months following sub-pectoral implantation of a permanent pacemaker, complaining of severe pocket-related pain, which arose spontaneously in the absence of direct trauma, intense physical activity or vigorous coughing, and was associated with normal day-to-day activity. To rule out a pacemaker re-infection, a native computed tomography and a positron emission tomography - computed tomography of the thorax were performed. Both modalities excluded an infection but showed a healing fracture and a focus of enhanced metabolic activity in the anterolateral part of the right second rib, indicating a non-traumatic or stress fracture of the bone. Consequently, a complete extraction of the pulse generator and both leads was performed and the smallest available single-chamber pulse generator with a single atrial electrode was implanted in the sub-fascial, pre-muscular pocket in the now recovered and uninfected left subclavicular region, alleviating patient’s severe pain symptoms and significantly enhancing her quality of life.Conclusions: In the absence of direct trauma, intense physical activity or vigorous coughing, we assume that in this asthenic girl a normal day-to-day motion of the right shoulder has persistently forced the sub-muscularly placed pulse generator toward thoracic wall, putting increased repetitive pressure force on the underlying bones, finally causing a fatigue stress fracture of the second rib. In asthenic phenotype patients with small thorax and short subclavicular distance, a sub-muscular pacemaker implantation can potentially cause unique and unexpected pocket-related adverse events necessitating advanced diagnostics and timely treatment.


2020 ◽  
Vol 3;23 (6;3) ◽  
pp. 293-298 ◽  
Author(s):  
Dimitrios K. Filippiadis

Background: Trigeminal neuralgia (TN) is associated with multiple mechanisms involving peripheral and central nervous system pathologies. Among percutaneous treatments offered, radiofrequency thermocoagulation (RFT) is associated with longer duration of pain relief. Mostly due to anatomic variation, cannulation of the foramen ovale using the Hartel approach has a failure rate of 5.17%. Objectives: To report safety and efficacy of continuous RFT with an alternative to Hartel anterior approach under computed tomography (CT) guidance in patients with classic TN. Study Design: Retrospective institutional database review; bicentral study. Setting: Although this was a retrospective database research, institutional review board approval was obtained. Methods: Institutional database review identified 10 patients (men 8, women 2) who underwent CT-guided RFT of the Gasserian ganglion. Preoperational evaluation included physical examination and magnetic resonance imaging. Under anesthesiology control and local sterility measures, a radiofrequency needle was advanced, and its approach was evaluated with sequential CT scans. Motor and sensory electrostimulation tests evaluated correct electrode location. Pain prior, 1 week, 1, 3, and 6 months after were compared by means of a numeric visual scale (NVS) questionnaire. Results: Mean self-reported pain NVS score prior to RFT was 9.2 ± 0.919 units. One week after the RFT mean NVS score was 1.10 ± 1.287 units (pain reduction mean value of 8.1 units). At 3 and 6 months after thermocoagulation the mean NVS score was 2.80 ± 1.549 units and 2.90 ± 1.370 units, respectively. There were no postoperative complications. Three patients experienced facial numbness, which gradually resolved over a period of 1 month. Limitations: Retrospective nature; small number of patients; lack of a control group undergoing a different treatment of TN. Conclusions: Percutaneous CT-guided RFT of the Gasserian ganglion constitutes a safe and efficacious technique for the treatment of TN, with significant pain relief and minimal complication rates improving life quality in this group of patients. Key words: Trigeminal nerve, neuralgia, pain, radiofrequency, ablation, percutaneous, computed tomography, imaging


Heart Rhythm ◽  
2020 ◽  
Vol 17 (12) ◽  
pp. 2023-2028 ◽  
Author(s):  
Eric Pagan ◽  
James Gabriels ◽  
Alexander Khodak ◽  
David Chang ◽  
Stuart Beldner ◽  
...  

2018 ◽  
Vol 41 (11) ◽  
pp. 1484-1490 ◽  
Author(s):  
José Luis Martínez-Sande ◽  
Moisés Rodríguez-Mañero ◽  
Javier García-Seara ◽  
Ramón Lago ◽  
Laila González-Melchor ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document