Heat Transfer for the Film-Cooled Vane of a 1-1/2 Stage High-Pressure Transonic Turbine—Part II: Effect of Cooling Variation on the Vane Airfoil and Inner End Wall

2012 ◽  
Vol 135 (2) ◽  
Author(s):  
Harika S. Kahveci ◽  
Charles W. Haldeman ◽  
Randall M. Mathison ◽  
Michael G. Dunn

The impact of film cooling on heat transfer is investigated for the high-pressure vane of a 1-1/2 stage high-pressure turbine operating at design corrected conditions. Cooling is supplied through three independently controllable circuits to holes in the inner and outer end wall, vane leading edge showerhead, and the pressure and suction surfaces of the airfoil, in addition to vane trailing edge slots. Four different overall cooling flow rates are investigated and one cooling circuit is varied independently. All results reported in this part of the paper are for a radial inlet temperature profile, one of the four profiles reported in part I of this paper. Part I describes the experimental setup, data quality, influence of inlet temperature profile, and influence of cooling when compared to a solid vane. This part of the paper shows that the addition of coolant reduces airfoil Stanton number by up to 60%. The largest reductions due to cooling are observed close to the inner end wall because the coolant to the majority of the vane is supplied by a plenum at the inside diameter. While the introduction of cooling has a significant impact on Stanton number, the impact of changing coolant flow rates is only observed for gauges near 5% span and on the inner end wall. This indicates that very little of the increased coolant mass flow reaches all the way to 90% span and the majority of the additional mass flow is injected into the core flow near the plenum. Turning off the vane outer cooling circuit that supplies coolant to the outer end wall holes, vane trailing edge slots, and three rows of holes on the pressure surface of the airfoil, has a local impact on Stanton number. Changes downstream of the holes on the airfoil pressure surface indicate that internal heat transfer from the coolant flowing inside the vane is important to the external heat transfer, suggesting that a conjugate heat-transfer solution may be required to achieve good external heat-transfer predictions in this area. Measurements on the inner end wall show that temperature reduction in the vane wake due to the trailing edge cooling is important to many points downstream of the vane.

Author(s):  
Harika S. Kahveci ◽  
Charles W. Haldeman ◽  
Randall M. Mathison ◽  
Michael G. Dunn

The impact of film cooling on heat transfer is investigated for the high-pressure vane of a one-and-one-half stage high-pressure turbine operating at design corrected conditions. Cooling is supplied through three independently controllable circuits to holes in the inner and outer endwall, vane leading edge showerhead, and the pressure and suction surfaces of the airfoil in addition to vane trailing edge slots. Four different overall cooling flow rates are investigated and one cooling circuit is varied independently. All results reported in this part of the paper are for a radial inlet temperature profile, one of the four profiles reported in Part I of this paper. Part I describes the experimental setup, data quality, influence of inlet temperature profile, and influence of cooling when compared to a solid vane. This part of the paper shows that the addition of coolant reduces airfoil Stanton Number by up to 60%. The largest reductions due to cooling are observed close to the inner endwall because the coolant to the majority of the vane is supplied by a plenum at the inside diameter. While the introduction of cooling has a significant impact on Stanton Number, the impact of changing coolant flow rates is only observed for gauges near 5% span and on the inner endwall. This indicates that very little of the increased coolant mass flow reaches all the way to 90% span and the majority of the additional mass flow is injected into the core flow near the plenum. Turning off the vane outer cooling circuit that supplies coolant to the outer endwall holes, vane trailing edge slots, and three rows of holes on the pressure surface of the airfoil, has a local impact on Stanton Number. Changes downstream of the holes on the airfoil pressure surface indicate that internal heat transfer from the coolant flowing inside the vane is important to the external heat transfer, suggesting that a conjugate heat-transfer solution may be required to achieve good external heat-transfer predictions in this area. Measurements on the inner endwall show that temperature reduction in the vane wake due to the trailing edge cooling is important to many points downstream of the vane.


2012 ◽  
Vol 135 (2) ◽  
Author(s):  
Harika S. Kahveci ◽  
Charles W. Haldeman ◽  
Randall M. Mathison ◽  
Michael G. Dunn

This paper investigates the vane airfoil and inner endwall heat transfer for a full-scale turbine stage operating at design corrected conditions under the influence of different vane inlet temperature profiles and vane cooling flow rates. The turbine stage is a modern 3D design consisting of a cooled high-pressure vane, an un-cooled high-pressure rotor, and a low-pressure vane. Inlet temperature profiles (uniform, radial, and hot streaks) are created by a passive heat exchanger and can be made circumferentially uniform to within ±5% of the bulk average inlet temperature when desired. The high-pressure vane has full cooling coverage on both the airfoil surface and the inner and outer endwalls. Two circuits supply coolant to the vane, and a third circuit supplies coolant to the rotor purge cavity. All of the cooling circuits are independently controlled. Measurements are performed using double-sided heat-flux gauges located at four spans of the vane airfoil surface and throughout the inner endwall region. Analysis of the heat transfer measured for the uncooled downstream blade row has been reported previously. Part I of this paper describes the operating conditions and data reduction techniques utilized in this analysis, including a novel application of a traditional statistical method to assign confidence limits to measurements in the absence of repeat runs. The impact of Stanton number definition is discussed while analyzing inlet temperature profile shape effects. Comparison of the present data (Build 2) to the data obtained for an uncooled vane (Build 1) clearly illustrates the impact of the cooling flow and its relative effects on both the endwall and airfoils. Measurements obtained for the cooled hardware without cooling applied agree well with the solid airfoil for the airfoil pressure surface but not for the suction surface. Differences on the suction surface are due to flow being ingested on the pressure surface and reinjected on the suction surface when coolant is not supplied for Build 2. Part II of the paper continues this discussion by describing the influence of overall cooling level variation and the influence of the vane trailing edge cooling on the vane heat transfer measurements.


Author(s):  
Harika S. Kahveci ◽  
Charles W. Haldeman ◽  
Randall M. Mathison ◽  
Michael G. Dunn

This paper investigates the vane airfoil and inner endwall heat transfer for a full-scale turbine stage operating at design corrected conditions under the influence of different vane inlet temperature profiles and vane cooling flow rates. The turbine stage is a modern 3-D design consisting of a cooled high-pressure vane, an un-cooled high-pressure rotor, and a low-pressure vane. Inlet temperature profiles (uniform, radial and hot streaks) are created by a passive heat exchanger and can be made circumferentially uniform to within ±5% of the bulk average inlet temperature when desired. The high-pressure vane has full cooling coverage on both the airfoil surface and the inner and outer endwalls. Two circuits supply coolant to the vane, and a third circuit supplies coolant to the rotor purge cavity. All of the cooling circuits are independently controlled. Measurements are performed using double-sided heat-flux gauges located at four spans of the vane airfoil surface and throughout the inner endwall region. Analysis of the heat transfer measured for the uncooled downstream blade row has been reported previously. Part I of this paper describes the operating conditions and data reduction techniques utilized in this analysis, including a novel application of a traditional statistical method to assign confidence limits to measurements in the absence of repeat runs. The impact of Stanton Number definition is discussed while analyzing inlet temperature profile shape effects. Comparison of the present data (Build 2) to the data obtained for an un-cooled vane (Build 1) clearly illustrates the impact of the cooling flow and its relative effects on both the endwall and airfoils. Measurements obtained for the cooled hardware without cooling applied agree well with the solid air-foil for the airfoil pressure surface but not for the suction surface. Differences on the suction surface are due to flow being ingested on the pressure surface and re-injected on the suction surface when coolant is not supplied for Build 2. Part II of the paper continues this discussion by describing the influence of overall cooling level variation and the influence of the vane trailing edge cooling on the vane heat transfer measurements.


Author(s):  
C. W. Haldeman ◽  
M. G. Dunn ◽  
R. M. Mathison

A fully cooled transonic HP turbine stage is utilized to investigate the combined effects of turbine stage cooling variation and vane inlet temperature profile on heat transfer to the blades with the stage operating at the proper design corrected conditions. For this series of experiments, both the vane row and the blade row were fully cooled. The matrix of experimental conditions included varying the cooling flow rates and the vane inlet temperature profiles to observe the overall effect on airfoil heat-transfer. The data presented in Part I focused on the aerodynamics of the fully cooled turbine for a subset of the cases investigating two vane inlet temperature profiles (uniform and radial), and three different cooling levels (none, nominal and high) for the high Reynolds number condition. This part of the paper focuses on the time-average heat-flux measurements on the blade and shroud region for the same cooling mass flow rates and vane inlet temperature profiles. The cooling effects are shown to be small and are centered primarily on the suction side of the airfoil. This relatively small influence is due to the ratio of the cooling gas to metal temperature being closer to 1 than the design value would dictate. The vane inlet temperature profile effects are more dominant, and using a Net Stanton Number Reduction Factor to compare the cases, an effect on the order of about 0.25 is demonstrated. This effect is due primarily to the change in the reference temperature used for the Stanton number calculation. The differences due to profile effects are small, but observable towards the trailing edge of both the blade and rotor shroud. This data set forms an excellent baseline for heat-flux calculations, as the variation in the main input conditions are well documented and do not produce large changes in the heat-flux. It provides insight into the flow physics of an actual engine and guidelines about proper normalization of variables for a cooled turbine stage, supporting further development of computational heat-flux modeling techniques.


2010 ◽  
Vol 132 (2) ◽  
Author(s):  
Sergio Amaral ◽  
Tom Verstraete ◽  
René Van den Braembussche ◽  
Tony Arts

This first paper describes the conjugate heat transfer (CHT) method and its application to the performance and lifetime prediction of a high pressure turbine blade operating at a very high inlet temperature. It is the analysis tool for the aerothermal optimization described in a second paper. The CHT method uses three separate solvers: a Navier–Stokes solver to predict the nonadiabatic external flow and heat flux, a finite element analysis (FEA) to compute the heat conduction and stress within the solid, and a 1D aerothermal model based on friction and heat transfer correlations for smooth and rib-roughened cooling channels. Special attention is given to the boundary conditions linking these solvers and to the stability of the complete CHT calculation procedure. The Larson–Miller parameter model is used to determine the creep-to-rupture failure lifetime of the blade. This model requires both the temperature and thermal stress inside the blade, calculated by the CHT and FEA. The CHT method is validated on two test cases: a gas turbine rotor blade without cooling and one with five cooling channels evenly distributed along the camber line. The metal temperature and thermal stress distribution in both blades are presented and the impact of the cooling channel geometry on lifetime is discussed.


Author(s):  
A. Rahim ◽  
L. He ◽  
E. Romero

One of the key considerations in high pressure (HP) turbine design is the heat load experienced by rotor blades. The impact of turbine inlet non-uniformities on the blades in the form of combined temperature and velocity traverses, typical for a lean burn combustor exit, has rarely been studied. For general HP turbine aerothermal designs, it is also of interest to understand how the behavior of a lean burn combustor traverses (hot streak and swirl) might contrast with those for rich burn combustion (largely hot streak only). In the present work, a computational study has been carried out on the aerothermal performance of a HP turbine stage under non-uniform temperature and velocity inlet profiles. The analyses are primarily conducted for two combined hot streak and swirl inlets, with opposite swirl directions. In addition, comparisons are made against a hot streak only case and a uniform inlet. The effects of three NGV shape configurations are investigated; namely, straight, compound lean (CL) and reverse compound lean (RCL). The present results show that there is a qualitative change in the roles played by heat transfer coefficient (HTC) and fluid driving (‘adiabatic wall’) temperature, Taw. It has been shown that the blade heat load distribution for a uniform inlet is dominated by HTC, whilst for a hot streak only case it is wholly influenced by Taw. However, in contrast to the hot streak only case, the case with a combined hot streak and swirl shows a role reversal with the HTC being dominant in determining the heat load. Additionally, it is seen that the swirling flow radially redistributes the hot fluid within the NGV passage considerably, leading to a much ‘flatter’ rotor inlet temperature profile compared to its hot streak only counterpart. Further, the rotor heat transfer characteristics for the cases with the combined traverses are shown to be strongly dependent on the NGV shaping and the inlet swirl direction, indicating the potential for future design space exploration. The present findings underline the need to clearly define relevant combustor exit temperature and velocity profiles when designing and optimizing NGVs for HP turbine aerothermal performance.


2011 ◽  
Vol 134 (3) ◽  
Author(s):  
C. W. Haldeman ◽  
M. G. Dunn ◽  
R. M. Mathison

A fully cooled transonic high-pressure turbine stage is utilized to investigate the combined effects of turbine stage cooling variation and vane inlet temperature profile on heat transfer to the blades with the stage operating at the proper design corrected conditions. For this series of experiments, both the vane row and the blade row were fully cooled. The matrix of experimental conditions included varying the cooling flow rates and the vane inlet temperature profiles to observe the overall effect on airfoil heat-transfer. The data presented in Part I focused on the aerodynamics of the fully cooled turbine for a subset of the cases investigating two vane inlet temperature profiles (uniform and radial) and three different cooling levels (none, nominal, and high) for the high Reynolds number condition. This part of the paper focuses on the time-average heat-flux measurements on the blade and shroud region for the same cooling mass flow rates and vane inlet temperature profiles. The cooling effects are shown to be small and are centered primarily on the suction side of the airfoil. This relatively small influence is due to the ratio of the cooling gas to metal temperature being closer to 1 than the design value would dictate. The vane inlet temperature profile effects are more dominant, and using a net Stanton number reduction factor to compare the cases, an effect on the order of about 0.25 is demonstrated. This effect is due primarily to the change in the reference temperature used for the Stanton number calculation. The differences due to profile effects are small but observable toward the trailing edge of both the blade and rotor shroud. This data set forms an excellent baseline for heat-flux calculations, as the variation in the main input conditions are well documented and do not produce large changes in the heat-flux. It provides insight into the flow physics of an actual engine and guidelines about proper normalization of variables for a cooled turbine stage, supporting further development of computational heat-flux modeling techniques.


2015 ◽  
Vol 19 (6) ◽  
pp. 2039-2048 ◽  
Author(s):  
Hafiz Ali ◽  
Muhammad Azhar ◽  
Musab Saleem ◽  
Qazi Saeed ◽  
Ahmed Saieed

The focus of this research paper is on the application of water based MgO nanofluids for thermal management of a car radiator. Nanofluids of different volumetric concentrations (i.e. 0.06%, 0.09% and 0.12%) were prepared and then experimentally tested for their heat transfer performance in a car radiator. All concentrations showed enhancement in heat transfer compared to the pure base fluid. A peak heat transfer enhancement of 31% was obtained at 0.12 % volumetric concentration of MgO in basefluid. The fluid flow rate was kept in a range of 8-16 liter per minute. Lower flow rates resulted in greater heat transfer rates as compared to heat transfer rates at higher flow rates for the same volumetric concentration. Heat transfer rates were found weakly dependent on the inlet fluid temperature. An increase of 8?C in inlet temperature showed only a 6% increase in heat transfer rate.


Author(s):  
T. Povey ◽  
K. S. Chana ◽  
T. V. Jones ◽  
J. Hurrion

Pronounced non-uniformities in combustor exit flow temperature (hot-streaks), which arise because of discrete injection of fuel and dilution air jets within the combustor and because of end-wall cooling flows, affect both component life and aerodynamics. Because it is very difficult to quantitatively predict the affects of these temperature non-uniformities on the heat transfer rates, designers are forced to budget for hot-streaks in the cooling system design process. Consequently, components are designed for higher working temperatures than the mass-mean gas temperature, and this imposes a significant overall performance penalty. An inadequate cooling budget can lead to reduced component life. An improved understanding of hot-streak migration physics, or robust correlations based on reliable experimental data, would help designers minimise the overhead on cooling flow that is currently a necessity. A number of recent research projects sponsored by a range of industrial gas turbine and aero-engine manufacturers attest to the growing interest in hot-streak physics. This paper presents measurements of surface and end-wall heat transfer rate for an HP nozzle guide vane (NGV) operating as part of a full HP turbine stage in an annular transonic rotating turbine facility. Measurements were conducted with both uniform stage inlet temperature and with two non-uniform temperature profiles. The temperature profiles were non-dimensionally similar to profiles measured in an engine. A difference of one half of an NGV pitch in the circumferential (clocking) position of the hot-streak with respect to the NGV was used to investigate the affect of clocking on the vane surface and end-wall heat transfer rate. The vane surface pressure distributions, and the results of a flow-visualisation study, which are also given, are used to aid interpretation of the results. The results are compared to two-dimensional predictions conducted using two different boundary layer methods. Experiments were conducted in the Isentropic Light Piston Facility (ILPF) at QinetiQ Farnborough, a short duration engine-size turbine facility. Mach number, Reynolds number and gas-to-wall temperature ratios were correctly modelled. It is believed that the heat transfer measurements presented in this paper are the first of their kind.


2021 ◽  
pp. 1-26
Author(s):  
Patrick René Jagerhofer ◽  
Marios Patinios ◽  
Tobias Glasenapp ◽  
Emil Goettlich ◽  
Federica Farisco

Abstract The imperative improvement in the efficiency of turbofan engines is commonly facilitated by increasing the turbine inlet temperature. This development has reached a point where also components downstream of the high-pressure turbine have to be adequately cooled. Such a component is the turbine center frame (TCF), known for a complex aerodynamic flow highly influenced by purge-mainstream interactions. The purge air, being injected through the wheelspace cavities of the upstream high-pressure turbine, bears a significant cooling potential for the TCF. Despite this, fundamental knowledge of the influencing parameters on heat transfer and film cooling in the TCF is still missing. This paper examines the influence of purge-to-mainstream blowing ratio, density ratio and purge swirl angle on heat transfer and film cooling in the TCF. The experiments are conducted in a sector-cascade test rig specifically designed for such heat transfer studies using infrared thermography and tailor-made flexible heating foils with constant heat flux. Three purge-to-mainstream blowing ratios and an additional no purge case are investigated. The purge flow is injected without swirl and also with engine-similar swirl angles. The purge swirl and blowing ratio significantly impact the magnitude and the spread of film cooling in the TCF. Increasing blowing ratios lead to an intensification of heat transfer. By cooling the purge flow, a moderate variation in purge-to-mainstream density ratio is investigated, and the influence is found to be negligible.