Effect of Internal Crossflow Velocity on Film Cooling Effectiveness—Part I: Axial Shaped Holes

2017 ◽  
Vol 140 (1) ◽  
Author(s):  
John W. McClintic ◽  
Joshua B. Anderson ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
Zachary D. Webster

The effect of feeding shaped film cooling holes with an internal crossflow is not well understood. Previous studies have shown that internal crossflow reduces film cooling effectiveness from axial shaped holes, but little is known about the mechanisms governing this effect. It was recently shown that the crossflow-to-mainstream velocity ratio is important, but only a few of these crossflow velocity ratios have been studied. This effect is of concern because gas turbine blades typically feature internal passages that feed film cooling holes in this manner. In this study, film cooling effectiveness was measured for a single row of axial shaped cooling holes fed by an internal crossflow with crossflow-to-mainstream velocity ratio varying from 0.2 to 0.6 and jet-to-mainstream velocity ratios varying from 0.3 to 1.7. Experiments were conducted in a low speed flat plate facility at coolant-to-mainstream density ratios of 1.2 and 1.8. It was found that film cooling effectiveness was highly sensitive to crossflow velocity at higher injection rates while it was much less sensitive at lower injection rates. Analysis of the jet shape and lateral spreading found that certain jet characteristic parameters scale well with the crossflow-to-coolant jet velocity ratio, demonstrating that the crossflow effect is governed by how coolant enters the film cooling holes.

Author(s):  
John W. McClintic ◽  
Joshua B. Anderson ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
Zachary D. Webster

The effect of feeding shaped film cooling holes with an internal crossflow is not well understood. Previous studies have shown internal crossflow reduces film cooling effectiveness from axial shaped holes, but little is known about the mechanisms governing this effect. It was recently shown that the crossflow-to-mainstream velocity ratio is important, but only a few of these crossflow velocity ratios have been studied. This effect is of concern because gas turbine blades typically feature internal passages that feed film cooling holes in this manner. In this study, film cooling effectiveness was measured for a single row of axial shaped cooling holes fed by an internal crossflow with crossflow-to-mainstream velocity ratio varying from 0.2–0.6 and jet-to-mainstream velocity ratios varying from 0.3–1.7. Experiments were conducted in a low speed flat plate facility at coolant-to-mainstream density ratios of 1.2 and 1.8. It was found that film cooling effectiveness was highly sensitive to crossflow velocity at higher injection rates, while it was much less sensitive at lower injection rates. Analysis of the jet shape and lateral spreading found that certain jet characteristic parameters scale well with the crossflow-to-coolant jet velocity ratio, demonstrating that the crossflow effect is governed by how coolant enters the film cooling holes.


Author(s):  
John W. McClintic ◽  
Joshua B. Anderson ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
Zachary D. Webster

In gas turbine engines, film cooling holes are commonly fed with an internal crossflow, the magnitude of which has been shown to have a notable effect on film cooling effectiveness. In Part I of this study, as well as in a few previous studies, the magnitude of internal crossflow velocity was shown to have a substantial effect on film cooling effectiveness of axial shaped holes. There is, however, almost no data available in the literature that shows how internal crossflow affects compound angle shaped film cooling holes. In Part II, film cooling effectiveness, heat transfer coefficient augmentation, and discharge coefficients were measured for a single row of compound angle shaped film cooling holes fed by internal crossflow flowing both in-line and counter to the span-wise direction of coolant injection. The crossflow-to-mainstream velocity ratio was varied from 0.2–0.6 and the injection velocity ratio was varied from 0.2–1.7. It was found that increasing the magnitude of the crossflow velocity generally caused degradation of the film cooling effectiveness, especially for in-line crossflow. An analysis of jet characteristic parameters demonstrated the importance of crossflow effects relative to the effect of varying the film cooling injection rate. Heat transfer coefficient augmentation was found to be primarily dependent on injection rate, although for in-line crossflow, increasing crossflow velocity significantly increased augmentation for certain conditions.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
John W. McClintic ◽  
Joshua B. Anderson ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
Zachary D. Webster

In gas turbine engines, film cooling holes are commonly fed with an internal crossflow, the magnitude of which has been shown to have a notable effect on film cooling effectiveness. In Part I of this study, as well as in a few previous studies, the magnitude of internal crossflow velocity was shown to have a substantial effect on film cooling effectiveness of axial shaped holes. There is, however, almost no data available in the literature that shows how internal crossflow affects compound angle shaped film cooling holes. In Part II, film cooling effectiveness, heat transfer coefficient augmentation, and discharge coefficients were measured for a single row of compound angle shaped film cooling holes fed by internal crossflow flowing both in-line and counter to the spanwise direction of coolant injection. The crossflow-to-mainstream velocity ratio was varied from 0.2 to 0.6 and the injection velocity ratio was varied from 0.2 to 1.7. It was found that increasing the magnitude of the crossflow velocity generally caused degradation of the film cooling effectiveness, especially for in-line crossflow. An analysis of jet characteristic parameters demonstrated the importance of crossflow effects relative to the effect of varying the film cooling injection rate. Heat transfer coefficient augmentation was found to be primarily dependent on injection rate, although for in-line crossflow, increasing crossflow velocity significantly increased augmentation for certain conditions.


2019 ◽  
Vol 141 (3) ◽  
Author(s):  
Dale W. Fox ◽  
Fraser B. Jones ◽  
John W. McClintic ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
...  

Most studies of turbine airfoil film cooling in laboratory test facilities have used relatively large plenums to feed flow into the coolant holes. However, a more realistic inlet condition for the film cooling holes is a relatively small channel. Previous studies have shown that the film cooling performance is significantly degraded when fed by perpendicular internal crossflow in a smooth channel. In this study, angled rib turbulators were installed in two geometric configurations inside the internal crossflow channel, at 45 deg and 135 deg, to assess the impact on film cooling effectiveness. Film cooling hole inlets were positioned in both prerib and postrib locations to test the effect of hole inlet position on film cooling performance. A test was performed independently varying channel velocity ratio and jet to mainstream velocity ratio. These results were compared to the film cooling performance of previously measured shaped holes fed by a smooth internal channel. The film cooling hole discharge coefficients and channel friction factors were also measured for both rib configurations with varying channel and inlet velocity ratios. Spatially averaged film cooling effectiveness is largely similar to the holes fed by the smooth internal crossflow channel, but hole-to-hole variation due to inlet position was observed.


Author(s):  
Dong Ho Rhee ◽  
Youn Seok Lee ◽  
Young Bong Kim ◽  
Hyung Hee Cho

An experimental study has been conducted to measure the temperature fields and the local film cooling effectiveness for two and three staggered rows of the rectangular-shaped film cooling holes with various blowing rates. Three different cooling hole shapes such as a straight rectangular hole, a rectangular hole with laterally expanded exit and a circular hole are tested. The rectangular cross-section has the aspect ratio of 2 at the hole inlet with the hydraulic diameter of 10 mm. The area ratio of the exit to the hole inlet is 1.8 for the rectangular hole with expanded exit, which is similar to a two-dimensional slot. The holes are spaced 3d apart in the spanwise direction and 4d apart in the streamwise direction with a staggered arrangement. Temperature fields are acquired using a three-axis traversing system equipped with a thermocouple rake. A thermochromic liquid crystals technique is applied to determine adiabatic film cooling effectiveness values and heat transfer coefficients on the test surface. The results show that the rectangular-shaped holes provide better performance than the cylindrical holes because the penetration of coolant is reduced and the lateral spreading of coolant is promoted. For rows of film cooling holes, the film cooling performance decreases with increasing blowing rate. However, the difference of hole shapes and blowing rates for film cooling performance is reduced with increasing the row of cooling holes.


Author(s):  
Ellen Wilkes ◽  
Joshua Anderson ◽  
John McClintic ◽  
David Bogard

This study focuses on specifics of gas turbine film cooling. Laboratory film cooling tests are important for industry because actual engine conditions are too hot, too small, and too fast to take accurate and high resolution measurements. Experiments are typically conducted using a plenum to feed coolant through round or shaped film cooling holes. Less common are experiments using cross-flow fed coolant, a method that flows coolant perpendicular to the mainstream flow and better represents engine designs. There are a few studies that have explored shaped holes in cross-flow, but none have looked at the effect cross-flow channel parameters other than Mach number. Here, the effectiveness of film cooling is quantified by measuring adiabatic effectiveness on a flat plate with a single row of shaped film cooling holes in cross-flow. A preliminary examination of the effect of cross-flow versus plenum fed coolant on the adiabatic effectiveness of the axial 7-7-7 shaped hole, a laidback fan-shaped hole with a 30 degree injection angle, is first conducted. Subsequently, the effects of two internal coolant parameters on film cooling effectiveness are presented: Reynold’s number inside the cross-flow channel, and velocity ratio (defined as the ratio of cross-flow channel average velocity to mainstream velocity). By measuring the effect of these parameters, a chain of relative importance can be generated and applied to future experimentation. Parameters that heavily influence film cooling effectiveness can be studied further and optimized for turbine film cooling design.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Andrew F Chen ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

The combined effects of upstream purge flow, slashface leakage flow, and discrete hole film cooling on turbine blade platform film cooling effectiveness were studied using the pressure sensitive paint (PSP) technique. As a continued study, discrete cylindrical holes were replaced by laidback fan-shaped (10-10-5) holes, which generally provide better film coverages on the endwall. Experiments were done in a five-blade linear cascade. The inlet and exit Mach numbers were 0.26 and 0.43, respectively. The inlet and exit mainstream Reynolds numbers based on the axial chord length of the blade were 475,000 and 720,000, respectively. A wide range of parameters was evaluated in this study. The coolant-to-mainstream mass flow ratio (MFR) was varied from 0.5%, 0.75%, to 1% for the upstream purge flow. For the platform film cooling holes and slashface gap, average blowing ratios (M) of 0.5, 1.0, and 1.5 were examined. Coolant-to-mainstream density ratios (DR) that range from 1 (close to low-temperature experiments) to 1.5 (intermediate DR) and 2 (close to engine conditions) were also examined. Purge flow swirl effect was studied particularly at a typical swirl ratio (SR) of 0.6. Area-averaged film cooling effectiveness results were compared between cylindrical and fan-shaped holes. The results indicate that the fan-shaped holes provide superior film coverage than cylindrical holes for platform film cooling especially at higher blowing ratios and momentum flux ratios.


Author(s):  
Dale W. Fox ◽  
Fraser B. Jones ◽  
John W. McClintic ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
...  

Most studies of turbine airfoil film cooling in laboratory test facilities have used relatively large plenums to feed flow into the coolant holes. However, a more realistic inlet condition for the film cooling holes is a relatively small channel. Previous studies have shown that the film cooling performance is significantly degraded when fed by perpendicular internal crossflow in a smooth channel. In this study, angled rib turbulators were installed in two geometric configurations inside the internal crossflow channel, at 45° and 135°, to assess the impact on film cooling effectiveness. Film cooling hole inlets were positioned in both pre-rib and post-rib locations to test the effect of hole inlet position on film cooling performance. A test was performed independently varying channel velocity ratio and jet to mainstream velocity ratio. These results were compared to the film cooling performance of previously measured shaped holes fed by a smooth internal channel. The film cooling hole discharge coefficients and channel friction factors were also measured for both rib configurations with varying channel and inlet velocity ratios. Spatially-averaged film cooling effectiveness is largely similar to the holes fed by the smooth internal crossflow channel, but hole-to-hole variation due to inlet position was observed.


Author(s):  
Zhihong Gao ◽  
Lesley M. Wright ◽  
Je-Chin Han

Film cooling is commonly used on the leading edge of turbine blades to protect the blade surface from hot mainstream gases in the turbine. Obtaining detailed film cooling effectiveness distributions on the leading edge can be challenging. This paper considers two measurement techniques which can be applied to the leading edge (modeled by a cylinder) to obtain detailed distributions of the film effectiveness. A steady state pressure sensitive paint (PSP) technique and a transient infrared (IR) thermography technique are used to obtain detailed film cooling effectiveness distributions on the cylinder. The cylinder, 7.62 cm in diameter, is placed in a low speed wind tunnel, with the mainstream flow having a Reynolds number of 100,900 (based on the cylinder diameter). The cylinder has two rows of film cooling holes located at ±15° from the cylinder’s stagnation line. The pitch-to-diameter ratio of the film holes is 4, and holes are inclined 30° in spanwise direction. PSP continues to show promise for film cooling effectiveness measurements. Detailed distributions can be obtained near the film cooling holes because this technique relies on mass transfer rather than heat transfer. In order to reduce the error caused by conduction in heat transfer experiments, transient measurement techniques are favorable. Transient IR measurements are taken, and film cooling effectiveness is determined on the cylinder’s surface. Although the effect of conduction is reduced with the transient IR technique (compared to a steady state heat transfer experiment), heat conduction through the cylinder has not been eliminated (or even minimized). Without correction, the results obtained from transient heat transfer experiments must be used cautiously. For this reason, PSP is developing a niche within the gas turbine community for detailed film cooling effectiveness measurements.


Author(s):  
Xiaokai Sun ◽  
Wei Peng

The effect of holes shape on film cooling was investigated numerically in the present study. Three cases of holes which are sister holes located in the downstream (case 1), upstream (case 2) and side (case 3) were studied when keeping the flow area and flow rate constant. Cylindrical hole was also investigated to make a comparison. The results showed film cooling effectiveness is higher at the blowing ratio M = 0.5 for cylindrical hole; while for the hole with sister holes, film cooling performance is better at corresponding blowing ratio M = 1.0 and it is better than that of the cylindrical hole. The reason is that the interaction between the mainstream and the cooling stream produces the counter-rotating vortex pairs (CVP) at high blowing ratio, which will make the hot mainstream underneath the cooling stream and lifts the cooling stream from the surface for the cylindrical hole. And the three cases of holes with sister holes can weaken the effect of the CVP.