scholarly journals Repowering of a Small Utility: A Unique Solution to a Unique Problem

1979 ◽  
Author(s):  
L. F. Fougere ◽  
H. G. Stewart ◽  
J. Bell

Citizens Utilities Company’s Kauai Electric Division is the electric utility on the Island of Kauai, fourth largest and westernmost as well as northernmost of the Hawaiian Islands. As a result of growing load requirements, additional generating capacity was required that would afford a high level of reliability and operating flexibility and good fuel economy at reasonable capital investment. To meet these requirements, a combined cycle arrangement was completed in 1978 utilizing one existing gas turbine-generator and one new gas turbine-generator, both exhausting to a new heat recovery steam generator which supplies steam to an existing steam turbine-generator. Damper controlled ducting directs exhaust gas from either gas turbine, one at a time, through the heat recovery steam generator. The existing oil-fired steam boiler remains available to power the steam turbine-generator independently or in parallel with the heat recovery steam generator. The gas turbines can operate either in simple cycle as peaking units or in combined cycle, one at a time, as base load units. This arrangement provides excellent operating reliability and flexibility, and the most favorable economics of all generating arrangements for the service required.

2020 ◽  
Vol 8 (9) ◽  
pp. 726
Author(s):  
Wahyu Nirbito ◽  
Muhammad Arif Budiyanto ◽  
Robby Muliadi

This study explains the performance analysis of a propulsion system engine of an LNG tanker using a combined cycle whose components are gas turbine, steam turbine, and heat recovery steam generator. The researches are to determine the total resistance of an LNG tanker with a capacity of 125,000 m3 by using the Maxsurf Resistance 20 software, as well as to design the propulsion system to meet the required power from the resistance by using the Cycle-Tempo 5.0 software. The simulation results indicate a maximum power of the system of about 28,122.23 kW with a fuel consumption of about 1.173 kg/s and a system efficiency of about 48.49% in fully loaded conditions. The ship speed can reach up to 20.67 knots.


2007 ◽  
Vol 11 (4) ◽  
pp. 143-156 ◽  
Author(s):  
Kumar Ravi ◽  
Krishna Rama ◽  
Rama Sita

Combined cycle power plants play an important role in the present energy sector. The main challenge in designing a combined cycle power plant is proper utilization of gas turbine exhaust heat in the steam cycle in order to achieve optimum steam turbine output. Most of the combined cycle developers focused on the gas turbine output and neglected the role of the heat recovery steam generator which strongly affects the overall performance of the combined cycle power plant. The present paper is aimed at optimal utilization of the flue gas recovery heat with different heat recovery steam generator configurations of single pressure and dual pressure. The combined cycle efficiency with different heat recovery steam generator configurations have been analyzed parametrically by using first law and second law of thermodynamics. It is observed that in the dual cycle high pressure steam turbine pressure must be high and low pressure steam turbine pressure must be low for better heat recovery from heat recovery steam generator.


Author(s):  
A. I. Zwebek ◽  
P. Pilidis

This paper investigates the possibility of applying a new technique called Gas/Steam Path Analysis (GSPA), that is based on the principles of Gas Path Analysis (GPA), to gas as well as steam turbine plants (as one unit) that are main parts of a combined cycle power plant by way of simulation. In order to facilitate this investigation two pieces of software were developed at Cranfield University. With this technique, it was possible to monitor the major components of the combined cycle, and hence predict the faults that may occur within the cycle beforehand. Faults looked at were, fouling and erosion of gas and steam turbine units, heat recovery steam generator degradation (scaling and/or ashe deposition), and condenser degradation. The obtained results from GSPA calculations of the cases investigated showed that “GSPA” technique can be equally applied to either gas turbine cycle, steam turbine cycle, or to the combination of the two in a form of combined cycle. The procedure, assumptions made, and the results obtained are presented and discussed herein.


1974 ◽  
Author(s):  
P. A. Berman

This paper describes the construction and initial operation fo a 260-MW combined cycle power generating plant consisting of two gas turbines, each with its own heat recovery steam generator. The steam, which is generated at 1200 lb 950 deg in each of the boilers, is combined to feed a single cylinder axial exhaust steam turbine. The paper describes the major components and operating cycle, the control system and some of the initial startup problems.


Author(s):  
Akber Pasha

In recent years the combined cycle has become a very attractive power plant arrangement because of its high cycle efficiency, short order-to-on-line time and flexibility in the sizing when compared to conventional steam power plants. However, optimization of the cycle and selection of combined cycle equipment has become more complex because the three major components, Gas Turbine, Heat Recovery Steam Generator and Steam Turbine, are often designed and built by different manufacturers. Heat Recovery Steam Generators are classified into two major categories — 1) Natural Circulation and 2) Forced Circulation. Both circulation designs have certain advantages, disadvantages and limitations. This paper analyzes various factors including; availability, start-up, gas turbine exhaust conditions, reliability, space requirements, etc., which are affected by the type of circulation and which in turn affect the design, price and performance of the Heat Recovery Steam Generator. Modern trends around the world are discussed and conclusions are drawn as to the best type of circulation for a Heat Recovery Steam Generator for combined cycle application.


Author(s):  
P. J. Dechamps

The last decade has seen remarkable improvement in gas turbine based power generation technologies, with the increasing use of natural gas-fuelled combined cycle units in various regions of the world. The struggle for efficiency has produced highly complex combined cycle schemes based on heat recovery steam generators with multiple pressure levels and possibly reheat. As ever, the evolution of these schemes is the result of a technico-economic balance between the improvement in performance and the increased costs resulting from a more complex system. This paper looks from the thermodynamic point of view at some simplified combined cycle schemes based on the concept of water flashing. In such systems, high pressure saturated water is taken off the high pressure drum and flashed into a tank. The vapour phase is expanded as low pressure saturated steam or returned to the heat recovery steam generator for superheating, whilst the liquid phase is recirculated through the economizer. With only one drum and three or four heat exchangers in the boiler as in single pressure level systems, the plant might have a performance similar to that of a more complex dual pressure level system. Various configurations with flash tanks are studied based on commercially available 150 MW-class E-technology gas turbines and compared with classical multiple pressure level combined cycles. Reheat units are covered, both with flash tanks and as genuine combined cycles for comparison purposes. The design implications for the heat recovery steam generator in terms of heat transfer surfaces are emphasized. Off-design considerations are also covered for the flash based schemes, as well as transient performances of these schemes, because the simplicity of the flash systems compared to normal combined cycles significantly affects the dynamic behaviour of the plant.


Author(s):  
Akber Pasha

Today the Heat Recovery Steam Generator (HRSG) has become an integral part of the combined cycle or Cogen plant because of its influence on other equipment. Therefore, the optimization of the HRSG has become one of the prime targets to improve the overall efficiency. The paper presents recent developments and concepts used in HRSG design which improve either the efficiency or the range of performance or both. The paper discusses three major areas of a HRSG - Superheater/Reheater, Economizer, and LP Evaporator/Feedwater Preheater. Depending upon the requirement, the user can implement one or more of the concepts to improve the total performance and/or the reliability.


2021 ◽  
Vol 65 (1) ◽  
pp. 93-104
Author(s):  
Onkar Singh ◽  
Gaitry Arora ◽  
Vinod Kumar Sharma

Heliostat-based solar thermal power system consisting of a combination of the Brayton cycle, Rankine cycle, and organic Rankine cycle is a potential option for harnessing solar energy for power generation. Among different options for improving the performance of solarized triple combined cycle the option of introducing intercooling and reheating in the gas turbine cycle and utilizing the waste heat for augmenting the power output needs investigation. Present study considers a solarized triple combined cycle with intercooling and reheating in gas turbines while using the heat rejected in intercooling in heat recovery vapour generator and heat recovery steam generator separately in two different arrangements. A comparison of two distinct cycle arrangements has been carried out based on Ist law and IInd law of thermodynamics with the help of thermodynamic parameters. Results show that triple combined cycle having intercooling heat used in heat recovery vapour generator offers maximum energy efficiency of 63.54% at 8 CPR & 300K ambient temperature and maximum exergetic efficiency of 38.37% at 14 CPR & 300 K. While the use of intercooling heat in heat recovery steam generator offers maximum energy and exergetic efficiency of 64.15% and 39.72% respectively at 16 CPR & 300 K ambient temperature.


Author(s):  
Donald A. Kolp ◽  
Charles E. Levey

Zorlu Enerji needed 35 MW of reliable power at a stable frequency to maintain constant speed on the spindles producing thread at its parent company’s textile plant in Bursa, Turkey. In December of 1996, Zorlu selected an LM2500+ combined cycle plant to fill its power-generating requirements. The LM2500+ has output of 26,810 KW at a heat rate of 9,735 Kj/Kwh. The combined cycle plant has an output of 35,165 KW and a heat rate of 7,428 Kj/Kwh. The plant operates in the simple cycle mode utilizing the LM2500+ and a bypass stack and in combined cycle mode using the 2-pressure heat recovery steam generator and single admission, 9.5 MW condensing steam turbine. The generator is driven through a clutch by the steam turbine from the exciter end and by the gas turbine from the opposing end. The primary fuel for the plant is natural gas; the backup fuel is naphtha. Utilizing a load bank, the plant is capable of accepting a 12 MW load loss when the utility breaker trips open; it can sustain this loss while maintaining frequency within 1% on the mill load. The frequency stabilizing capability prevents overspeeding of the spindles, breakage of thousands of strands of thread and a costly shutdown of the mill. A description of the equipment, operation and performance illustrates the unique features of this versatile, compact and efficient generating unit.


Author(s):  
Sanjay ◽  
Onkar Singh ◽  
B. N. Prasad

This paper reports on the development requirements of gas/steam combined cycle with an aim to achieve plant efficiency greater than 62% through various development possibilities in gas turbine and steam turbine cycle by taking a reference combined cycle configuration (MS9001H gas turbine and three pressure heat recovery steam generator with reheat). The innovative development possibilities include the advanced inlet design to reduce pressure loss, the increase in turbine inlet temperature, use of advanced turbine blade material, increased component efficiency, improved turbine cooling technologies along with better cooling medium, incorporating intercooling, reheat and regeneration either separately or in combination with simple gas turbine cycle using higher compressor pressure ratio, better utilization of heat recovery steam generator, minimum stack temperature, single shaft system configuration, etc. Based on the quantification of each development item, if incorporated in reference cycle, it has been estimated that the combined cycle as the potential to achieve the plant efficiency in excess of 63%.