Account of Film Turbulence for Predicting Film Cooling Effectiveness in Gas Turbine Combustors

Author(s):  
G. J. Sturgess

The paper deals with a small but important part of the overall gas turbine engine combustion system and continues earlier published work on turbulence effects in film cooling to cover the case of film turbulence. Film cooling of the gas turbine combustor liner imposes certain geometric limitations on the coolant injection device. The impact of practical film injection geometry on the cooling is one of increased rates of film decay when compared to the performance from idealized injection geometries at similar injection conditions. It is important to combustor durability and life estimation to be able to predict accurately the performance obtainable from a given practical slot. The coolant film is modeled as three distinct regions, and the effects of injection slot geometry on the development of each region are described in terms of film turbulence intensity and initial circumferential non-uniformity of the injected coolant. The concept of the well-designed slot is introduced and film effectiveness is shown to be dependent on it. Only slots which can be described as well-designed are of interest in practical equipment design. A prediction procedure is provided for well-designed slots which describes growth of the film downstream of the first of the three film regions. Comparisons of predictions with measured data are made for several very different well-designed slots over a relatively wide range of injection conditions, and good agreement is shown.

1980 ◽  
Vol 102 (3) ◽  
pp. 524-534 ◽  
Author(s):  
G. J. Sturgess

The paper deals with a small but important part of the overall gas turbine engine combustion system and continues earlier published work on turbulence effects in film cooling to cover the case of film turbulence. Film cooling of the gas turbine combustor liner imposes certain geometric limitations on the coolant injection device. The impact of practical film injection geometry on the cooling is one of increased rates of film decay when compared to the performance from idealized injection geometries at similar injection conditions. It is important to combustor durability and life estimation to be able to predict accurately the performance obtainable from a given practical slot. The coolant film is modeled as three distinct regions, and the effects of injection slot geometry on the development of each region are described in terms of film turbulence intensity and initial circumferential non-uniformity of the injected coolant. The concept of the well-designed slot is introduced and film effectiveness is shown to be dependent on it. Only slots which can be described as well-designed are of interest in practical equipment design. A prediction procedure is provided for well-designed slots which describes growth of the film downstream of the first of the three film regions. Comparisons of predictions with measured data are made for several very different well-designed slots over a relatively wide range of injection conditions, and good agreement is shown.


Author(s):  
Srinivasa Rao Para ◽  
Xianchang Li ◽  
Ganesh Subbuswamy

To improve the gas turbine thermal performance, apart from using a high compression ratio, the turbine inlet temperature must be increased. Therefore, the gas temperature inside the combustion chamber needs to be maintained at a very high level. Hence, cooling of the combustor liner becomes critical. Among all the cooling techniques, film cooling has been successfully applied to cool the combustor liner. In film cooling, coolant air is introduced through discrete holes and forms a thin film between the hot gases and the inner surface of the liner, so that the inner wall can be protected from overheating. The film will be destroyed in the downstream flow because of mixing of hot and cold gases. The present work focuses on numerical study of film cooling under operating conditions, i.e., high temperature and pressure. The effect of coolant injection angles and blowing ratios on film cooling effectiveness is studied. A promising technology, cooling with mist injection, is studied under operating conditions. The effect of droplet size and mist concentration is also analyzed. The results of this study indicate that the film cooling effectiveness can increase ∼11% at gas turbine operating conditions with mist injection of 2% coolant air when droplets of 10μm and a blowing ratio of 1.0 are applied. The cooling performance can be further improved by higher mist concentration. The commercial CFD software, Fluent 6.3.26, is used in this study and the standard k-ε model with enhanced wall functions is adopted as the turbulence model.


2005 ◽  
Vol 127 (4) ◽  
pp. 718-725 ◽  
Author(s):  
Michael Gritsch ◽  
Will Colban ◽  
Heinz Schär ◽  
Klaus Döbbeling

This study evaluates the impact of typical cooling hole shape variations on the thermal performance of fan-shaped film holes. A comprehensive set of experimental test cases featuring 16 different film-cooling configurations with different hole shapes have been investigated. The shape variations investigated include hole inlet-to-outlet area ratio, hole coverage ratio, hole pitch ratio, hole length, and hole orientation (compound) angle. Flow conditions applied cover a wide range of film blowing ratios M=0.5 to 2.5 at an engine-representative density ratio DR=1.7. An infrared thermography data acquisition system is used for highly accurate and spatially resolved surface temperature mappings. Accurate local temperature data are achieved by an in situ calibration procedure with the help of thermocouples embedded in the test plate. Detailed film-cooling effectiveness distributions and discharge coefficients are used for evaluating the thermal performance of a row of fan-shaped film holes. An extensive variation of the main geometrical parameters describing a fan-shaped film-cooling hole is done to cover a wide range of typical film-cooling applications in current gas turbine engines. Within the range investigated, laterally averaged film-cooling effectiveness was found to show only limited sensitivity from variations of the hole geometry parameters. This offers the potential to tailor the hole geometry according to needs beyond pure cooling performance, e.g., manufacturing facilitations.


Author(s):  
J. S. Piggush ◽  
T. W. Simon

The first stage vane section of a modern gas turbine engine is assembled with a gap between the combustor and the vane platform and a second gap on the platform. To prevent ingression, leakage flow is provided through each gap. In this paper, the effectiveness of the leakage flow as an endwall film coolant is measured. The cascade geometry includes axial contouring of the cooled endwall and several step configurations for each gap. The steps reflect assembly or differential thermal growth misalignment. Various blowing rates are applied through each gap to allow assessment of the changes in effectiveness with changes in leakage rate. Thus, the results presented herein show how the gaps, steps, and leakage rates alter the cooling effectiveness of the leakage flow. Shown are some cases where steps improve the film cooling effectiveness. In other cases, enhanced mixing due to gaps, steps, or increased leakage reduces effectiveness.


Author(s):  
Stefan Baldauf ◽  
Michael Scheurlen

A standard CFD code with two-layer k-ε-model was used to calculate film cooling effectiveness of flat plate test cases. Experimental data from the literature were taken to perform extensive validation of the code for film cooling effectiveness prediction. Emphasis was put on injection of cooling gas through one row of cylindrical holes in the streamwise direction. Blowing ratio, density ratio, blowing angle, pitch, and hole length to diameter ratio were varied in a wide range. It was found that the code is well suited for the prediction of lateral averaged film cooling effectiveness for common film cooling conditions. A similarity analysis is presented for the prescribed film cooling problem to isolate the influence parameters of flow properties and geometry. A reduction of the parameters of influence was achieved using physical implications. The magnitude of the remaining parameters was compared for literature reported experimental results and gas turbine applications. It was found that experimental realized Reynolds and Eckert numbers are mostly far from turbine engine conditions. Therefore the validated CFD code was used to extrapolate the experimental configuration to engine like conditions. It was found that the examined Reynolds and Eckert numbers had no significant impact on lateral averaged film cooling effectiveness. It is hence possible to present a reduced but complete set of the governing influence parameters on the discussed film cooling problem.


2003 ◽  
Vol 125 (4) ◽  
pp. 648-657 ◽  
Author(s):  
Jae Su Kwak ◽  
Je-Chin Han

Experimental investigations were performed to measure the detailed heat transfer coefficients and film cooling effectiveness on the squealer tip of a gas turbine blade in a five-bladed linear cascade. The blade was a two-dimensional model of a first stage gas turbine rotor blade with a profile of the GE-E3 aircraft gas turbine engine rotor blade. The test blade had a squealer (recessed) tip with a 4.22% recess. The blade model was equipped with a single row of film cooling holes on the pressure side near the tip region and the tip surface along the camber line. Hue detection based transient liquid crystals technique was used to measure heat transfer coefficients and film cooling effectiveness. All measurements were done for the three tip gap clearances of 1.0%, 1.5%, and 2.5% of blade span at the two blowing ratios of 1.0 and 2.0. The Reynolds number based on cascade exit velocity and axial chord length was 1.1×106 and the total turning angle of the blade was 97.9 deg. The overall pressure ratio was 1.2 and the inlet and exit Mach numbers were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7%. Results showed that the overall heat transfer coefficients increased with increasing tip gap clearance, but decreased with increasing blowing ratio. However, the overall film cooling effectiveness increased with increasing blowing ratio. Results also showed that the overall film cooling effectiveness increased but heat transfer coefficients decreased for the squealer tip when compared to the plane tip at the same tip gap clearance and blowing ratio conditions.


2019 ◽  
Vol 141 (3) ◽  
Author(s):  
Dale W. Fox ◽  
Fraser B. Jones ◽  
John W. McClintic ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
...  

Most studies of turbine airfoil film cooling in laboratory test facilities have used relatively large plenums to feed flow into the coolant holes. However, a more realistic inlet condition for the film cooling holes is a relatively small channel. Previous studies have shown that the film cooling performance is significantly degraded when fed by perpendicular internal crossflow in a smooth channel. In this study, angled rib turbulators were installed in two geometric configurations inside the internal crossflow channel, at 45 deg and 135 deg, to assess the impact on film cooling effectiveness. Film cooling hole inlets were positioned in both prerib and postrib locations to test the effect of hole inlet position on film cooling performance. A test was performed independently varying channel velocity ratio and jet to mainstream velocity ratio. These results were compared to the film cooling performance of previously measured shaped holes fed by a smooth internal channel. The film cooling hole discharge coefficients and channel friction factors were also measured for both rib configurations with varying channel and inlet velocity ratios. Spatially averaged film cooling effectiveness is largely similar to the holes fed by the smooth internal crossflow channel, but hole-to-hole variation due to inlet position was observed.


Author(s):  
Firat Kiyici ◽  
Ahmet Topal ◽  
Ender Hepkaya ◽  
Sinan Inanli

A numerical study, based on experimental work of Inanli et al. [1] is conducted to understand the heat transfer characteristics of film cooled test plates that represent the gas turbine combustor liner cooling system. Film cooling tests are conducted by six different slot geometries and they are scaled-up model of real combustor liner. Three different blowing ratios are applied to six different geometries and surface cooling effectiveness is determined for each test condition by measuring the surface temperature distribution. Effects of geometrical and flow parameters on cooling effectiveness are investigated. In this study, Conjugate Heat Transfer (CHT) simulations are performed with different turbulence models. Effect of the turbulent Prandtl Number is also investigated in terms of heat transfer distribution along the measurement surface. For this purpose, turbulent Prandtl number is calculated with a correlation as a function of local surface temperature gradient and its effect also compared with the constant turbulent Prandtl numbers. Good agreement is obtained with two-layered k–ϵ with modified Turbulent Prandtl number.


Author(s):  
S. Baldauf ◽  
A. Schulz ◽  
S. Wittig

Local adiabatic film cooling effectiveness on a flat plate surface downstream a row of cylindrical holes was investigated. Geometrical parameters like blowing angle and hole pitch as well as the flow parameters blowing rate and density ratio were varied in a wide range emphasizing on engine relevant conditions. An IR-thermography technique was used to perform local measurements of the surface temperature field. A spatial resolution of up to 7 data points per hole diameter extending up to 80 hole diameters downstream of the ejection location was achieved. Since all technical surface materials have a finite thermoconductivity, no ideal adiabatic conditions could be established. Therefore, a procedure for correcting the measured surface temperature data based on a Finite Element analysis was developed. Heat loss over the backside of the testplate and remnant heat flux within the testplate in lateral and streamwise direction were taken into account. The local effectiveness patterns obtained are systematically analyzed to quantify the influence of the various parameters. As a result, a detailed description of the characteristics of local adiabatic film cooling effectiveness is given. Furthermore, the locally resolved experimental results can serve as a data base for the validation of CFD-codes predicting discrete hole film cooling.


Sign in / Sign up

Export Citation Format

Share Document