scholarly journals Low-Aspect-Ratio Rib Heat Transfer Coefficient Measurements in a Square Channel

Author(s):  
M. E. Taslim ◽  
G. J. Korotky

Cooling channels, roughened with repeated ribs, are commonly employed as a means of cooling turbine blades. The increased level of mixing induced by these ribs enhances the convective heat transfer in the blade cooling cavities. Many previous investigations have focused on the heat transfer coefficient on the surfaces between these ribs and only a few studies report the heat transfer coefficient on the rib surfaces themselves. The present study investigated the heat transfer coefficient on the surfaces of round-corner, low-aspect-ratio (ARrib = 0.667) ribs. Twelve rib geometries, comprising of three rib height-to-channel hydraulic diameter (blockage ratios) of 0.133, 0.167, and 0.25 as well as three rib spacings (pitch-to-height ratios) of 5, 8.5, and 10 were investigated for two distinct thermal boundary conditions of heated and unheated channel walls. A square channel, roughened with low-aspect-ratio ribs on two opposite walls in a staggered manner end perpendicular to the flow direction was tested. An instrumented copper rib was positioned either in the middle of the rib arrangements or in the furthest upstream location. Rib heat transfer coefficient as well as the channel friction factor for these low-aspect-ratio ribs were also compared with those of square ribs, reported previously by the authors. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region of the passage wall were also compared.

1998 ◽  
Vol 120 (4) ◽  
pp. 831-838 ◽  
Author(s):  
M. E. Taslim ◽  
G. J. Korotky

Cooling channels, roughened with repeated ribs, are commonly employed as a means of cooling turbine blades. The increased level of mixing induced by these ribs enhances the convective heat transfer in the blade cooling cavities. Many previous investigations have focused on the heat transfer coefficient on the surfaces between these ribs and only a few studies report the heat transfer coefficient on the rib surfaces themselves. The present study investigated the heat transfer coefficient on the surfaces of round-corner, low-aspect-ratio (ARrib = 0.667) ribs. Twelve rib geometries, comprising three rib height-to-channel hydraulic diameters (blockage ratios) of 0.133, 0.167, and 0.25 as well as three rib spacings (pitch-to-height ratios) of 5, 8.5, and 10 were investigated for two distinct thermal boundary conditions of heated and unheated channel walls. A square channel, roughened with low-aspect-ratio ribs on two opposite walls in a staggered manner and perpendicular to the flow direction, was tested. An instrumented copper rib was positioned either in the middle of the rib arrangements or in the furthest upstream location. Both rib heat transfer coefficient and channel friction factor for these low-aspect-ratio ribs were also compared with those of square ribs, reported previously by the authors. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region of the passage wall were also compared.


1999 ◽  
Vol 121 (2) ◽  
pp. 272-280 ◽  
Author(s):  
M. E. Taslim ◽  
A. Lengkong

Cooling channels, roughened with repeated ribs, are commonly employed as a means of cooling turbine blades. The increased level of mixing induced by these ribs enhances the convective heat transfer in the blade cooling cavities. Many previous investigations have focused on the heat transfer coefficient on the surfaces between these ribs and only a few studies report the heat transfer coefficient on the rib surfaces themselves. The present study investigated the heat transfer coefficient on the surfaces of 45 deg, round-corner ribs. Three staggered rib geometries corresponding to blockage ratios of 0.133, 0.167, and 0.25 were tested in a square channel for pitch-to-height ratios of 5, 8.5, and 10, and for two distinct thermal boundary conditions of heated and unheated channel wall. Comparisons were made between the surface-averaged heat transfer coefficients and channel friction factors for sharp-and round-corner ribs and 45 versus 90 deg ribs, reported previously. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the ribroughened region were also compared. It was concluded that: (a) For the geometries tested, the rib average heat transfer coefficient was much higher than that for the area between the ribs. (b) The general effect of rounding the rib corners was a decrease in both rib heat transfer coefficient and channel pressure drop. (c) For the highest blockage ratio ribs (e/Dh = 0.25), 90 deg ribs performed superior to 45 deg ribs. However, this trend reversed for smaller rib blockage ratios. (d) Heat transfer coefficients for the two smaller rib geometries (e/Dh = 0.133 and 0.167) did not vary significantly with the pitch-to-height ratio in the range tested. However, the heat transfer coefficient for the high blockage rib geometry increased significantly as the ribs were brought closer to each other. (e) Under otherwise identical conditions, ribs in the furthest upstream position produced lower heat transfer coefficients than those in the midstream position. (f) Rib thermal performance decreased with the rib blockage ratio. The smallest rib geometry (e/Dh = 0.133) at a pitch-to-height ratio of 10 and the largest rib geometry (e/Dh = 0.25) at a pitch-to-height ratio of 5, both in midstream position, produced the highest and the lowest thermal performances, respectively.


Author(s):  
M. E. Taslim ◽  
A. Lengkong

For high blockage ribs with large heat transfer areas, commonly used in small gas turbine blades, the rib heat transfer is a significant portion of the overall heat transfer in the cooling passages. Three staggered 45° rib geometries corresponding to blockage ratios of 0.133, 0.167 and 0.25 were tested in a square channel for pitch-to-height ratios of 5, 8.5 and 10, and for two distinct thermal boundary conditions of heated and unheated channel walls. Comparisons were made between the surface averaged heat transfer coefficients and friction factors for 45° ribs, and 90° ribs reported previously. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region were also compared. It was concluded that: a) For the geometries tested, the rib average heat transfer coefficient was much higher than that for the area between the ribs. b) Except for two cases corresponding to the highest blockage ribs mounted at pitch-to-height ratios of 8.5 and 10 for which the heat transfer results of 45° ribs were very close to those of 90° ribs, 45° ribs produced higher heat transfer coefficients than 90° ribs. c) At pitch-to-height ratios of 8.5 and 10, all 45° ribs produced lower friction factors than 90° ribs. However, when they were brought closer to each other (S/e=5), they produced higher friction factors than 90° ribs. d) Heat transfer coefficients for the two smaller rib geometries (e/Dh=0.133 and 0.167) did not vary significantly with the pitch-to-height ratio in the range tested. However, the heat transfer coefficient for the high blockage rib geometry increased significantly as the ribs were brought closer to each other. e) Under otherwise identical conditions, ribs in the furthest upstream position produced lower heat transfer coefficients than those in the midstream position. f) Rib thermal performance decreased with the rib blockage ratio. For both angles of attack, the smallest rib geometry in the midstream position and at a pitch-to-height ratio of 10 had the highest thermal performance, and the highest blockage rib in the furthest upstream position produced the lowest thermal performance.


Author(s):  
M. E. Taslim ◽  
A. Lengkong

Cooling channels, roughened with repeated ribs, are commonly employed as a means of cooling turbine blades. The increased level of mixing induced by these ribs enhances the convective heat transfer in the blade cooling cavities. Many previous investigations have focused on the heat transfer coefficient on the surfaces between these ribs and only a few studies report the heat transfer coefficient on the rib surfaces themselves. The present study investigated the heat transfer coefficient on the surfaces of 45°, round-comer ribs. Three staggered rib geometries corresponding to blockage ratios of 0.133, 0.167 and 0.25 were tested in a square channel for pitch-to-haight ratios of 5, 8.5 and 10, and for two distinct thermal boundary conditions of heated and unhealed channel wall. Comparisons were made between the surface averaged heat transfer coefficients and channel friction factors for sharp- and round-comer ribs and 45° versus 90° ribs, reported previously. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region were also compared. It was concluded that: a) For the geometries tested, the rib average heat transfer coefficient was much higher than that for the area between the ribs. b) General effect of rounding the rib corners was a decrease in both rib heat transfer coefficient and channel pressure drop. c) For the highest blockage ratio ribs (e/Dh = 0.25), 90° ribs performed superior to 45° ribs. However, this trend reversed for smaller rib blockage ratios. d) Heat transfer coefficients for the two smaller rib geometries (e/Dh = 0.133 and 0.167) did not vary significantly with the pitch-to-height ratio in the range tested. However, the heat transfer coefficient for the high blockage rib geometry increased significantly as the ribs were brought closer to each other. e) Under otherwise identical conditions, ribs in the furthest upstream position produced lower heat transfer coefficients than those in the midstream position. f) Rib thermal performance decreased with the rib blockage ratio. The smallest rib geometry (e/Dh = 0.133) at a pitch-to-height ratio of 10 and the largest rib geometry (e/Dh = 0.25) at a pitch-to-height ratio of 5, both in midstream position, produced the highest and the lowest thermal performances, respectively.


1998 ◽  
Vol 120 (3) ◽  
pp. 571-580 ◽  
Author(s):  
M. E. Taslim ◽  
A. Lengkong

For high-blockage ribs with large heat transfer areas, commonly used in small gas turbine blades, the rib heat transfer is a significant portion of the overall heat transfer in the cooling passages. Three staggered 45 deg rib geometries corresponding to blockage ratios of 0.133, 0.167, and 0.25 were tested in a square channel for pitch-to-height ratios of 5, 8.5, and 10, and for two distinct thermal boundary conditions of heated and unheated channel walls. Comparisons were made between the surface-averaged heat transfer coefficients and friction factors for 45 deg ribs, and 90 deg ribs reported previously. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region were also compared. It was concluded that: (a) For the geometries tested, the rib average heat transfer coefficient was much higher than that for the area between the ribs. (b) Except for two cases corresponding to the highest blockage ribs mounted at pitch-to-height ratios of 8.5 and 10 for which the heat transfer results of 45 deg ribs were very close to those of 90 deg ribs, 45 deg ribs produced higher heat transfer coefficients than 90 deg ribs. (c) At pitch-to-height ratios of 8.5 and 10, all 45 deg ribs produced lower friction factors than 90 deg ribs. However, when they were brought closer to each other (S/e = 5), they produced higher friction factors than 90 deg ribs. (d) Heat transfer coefficients for the two smaller rib geometries (e/Dh = 0.133 and 0.167) did not vary significantly with the pitch-to-height ratio in the range tested. However, the heat transfer coefficient for the high blockage rib geometry increased significantly as the ribs were brought closer to each other. (e) Under otherwise identical conditions, ribs in the furthest upstream position produced lower heat transfer coefficients than those in the midstream position. (f) Rib thermal performance decreased with the rib blockage ratio. For both angles of attack, the smallest rib geometry in the midstream position and at a pitch-to-height ratio of 10 had the highest thermal performance, and the highest blockage rib in the furthest upstream position produced the lowest thermal performance.


2005 ◽  
Vol 2005 (1) ◽  
pp. 60-66 ◽  
Author(s):  
M. E. Taslim ◽  
H. Liu

Experimental investigations have shown that the enhancement in heat transfer coefficients for air flow in a channel roughened with low blockage(e/Dh<0.1)angled ribs is on the average higher than that roughened with90∘ribs of the same geometry. Secondary flows generated by the angled ribs are believed to be responsible for these higher heat transfer coefficients. These secondary flows also create a spanwise variation in the heat transfer coefficient on the roughened wall with high levels of the heat transfer coefficient at one end of the rib and low levels at the other end. In an effort to investigate the thermal behavior of the angled ribs at elevated Reynolds numbers, a combined numerical and experimental study was conducted. In the numerical part, a square channel roughened with45∘ribs of four blockage ratios(e/Dh)of0.10,0.15,0.20, and0.25, each for a fixed pitch-to-height ratio(P/e)of10, was modeled. Sharp as well as round-corner ribs (r/e=0and0.25) in a staggered arrangement were studied. The numerical models contained the smooth entry and exit regions to simulate exactly the tested geometries. A pressure-correction-based, multiblock, multigrid, unstructured/adaptive commercial software was used in this investigation. Standard high Reynolds numberk−εturbulence model in conjunction with the generalized wall function for most parts was used for turbulence closure. The applied thermal boundary conditions to the CFD models matched the test boundary conditions. In the experimental part, a selected number of these geometries were built and tested for heat transfer coefficients at elevated Reynolds numbers up to 150 000, using a liquid crystal technique. Comparisons between the test and numerically evaluated results showed reasonable agreements between the two for most cases. Test results showed that (a)45∘angled ribs with high blockage ratios(>0.2)at elevated Reynolds numbers do not exhibit a good thermal performance, that is, beyond this blockage ratio, the heat transfer coefficient decreases with the rib blockage and (b) CFD could be considered as a viable tool for the prediction of heat transfer coefficients in a rib-roughened test section.


Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


Author(s):  
Vijay K. Garg ◽  
Ali A. Ameri

A three-dimensional Navier-Stokes code has been used to compute the heat transfer coefficient on two film-cooled turbine blades, namely the VKI rotor with six rows of cooling holes including three rows on the shower head, and the C3X vane with nine rows of holes including five rows on the shower head. Predictions of heat transfer coefficient at the blade surface using three two-equation turbulence models, specifically, Coakley’s q-ω model, Chien’s k-ε model and Wilcox’s k-ω model with Menter’s modifications, have been compared with the experimental data of Camci and Arts (1990) for the VKI rotor, and of Hylton et al. (1988) for the C3X vane along with predictions using the Baldwin-Lomax (B-L) model taken from Garg and Gaugler (1995). It is found that for the cases considered here the two-equation models predict the blade heat transfer somewhat better than the B-L model except immediately downstream of the film-cooling holes on the suction surface of the VKI rotor, and over most of the suction surface of the C3X vane. However, all two-equation models require 40% more computer core than the B-L model for solution, and while the q-ω and k-ε models need 40% more computer time than the B-L model, the k-ω model requires at least 65% more time due to slower rate of convergence. It is found that the heat transfer coefficient exhibits a strong spanwise as well as streamwise variation for both blades and all turbulence models.


Metals ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. 1367
Author(s):  
Nino Wolff ◽  
Golo Zimmermann ◽  
Uwe Vroomen ◽  
Andreas Bührig-Polaczek

Local heat transfer in gravity die casting is of great importance for precision in terms of distortion, mechanical properties, and the quality of the castings due to its effect on solidification. Depending on contact conditions such as liquid melt to solid mold, a gap between mold and component, or contact pressure between casting and mold as a result of shrinkage, there are very large differences in heat transfer. The influences of mold material, mold coating and its influence of aging, mold temperature control, and layout on the heat transfer coefficient (HTC) were investigated experimentally for different contact cases. The experiments were carried out on a rotationally symmetrical experimental setup with modular exchangeable die inserts and cores using an AlSi7Mg0.3 alloy. From the results of the individual test series, the quantitative shares of the above-mentioned influencing variables in the respective effective heat transfer coefficients were determined by means of analysis of variance. From this, the parameters having the most significant influence on the local heat balance were derived.