CFD Validation of Gas Injection Into Stagnant Water

Author(s):  
Ashraf Ibrahim ◽  
David Felde ◽  
Bernard Riemer ◽  
Mark Wendel

Investigations in the area of two-phase flow at the Oak Ridge National Laboratory’s (ORNL) Spallation Neutron Source (SNS) facility are progressing. It is expected that the target vessel lifetime could be extended by introducing gas into the liquid mercury target. As part of an effort to validate the two-phase computational fluid dynamics (CFD) model, simulations and experiments of gas injection in stagnant water have been completed. The volume of fluid (VOF) method as implemented in ANSYS-CFX was used to simulate the unsteady two-phase flow of gas injection into stagnant water. Flow visualization data were obtained with a high-speed camera for the comparison of predicted and measured bubble sizes and shapes at various stages of the bubble growth, detachment, and gravitational rise. The CFD model is validated with these experimental measurements at different gas flow rates. The acoustic waves emitted at the time of detachment and during subsequent oscillations of the bubble were recorded with a microphone. The acoustic signature aspect of this validation is particularly interesting since it has applicability to the injection of gas into liquid mercury, which is opaque.

Author(s):  
Mehmet Sorgun ◽  
Reza E. Osgouei ◽  
M. Evren Ozbayoglu ◽  
A. Murat Ozbayoglu

Although flow of two-phase fluids is studied in detailed for pipes, there exists a lack of information about aerated fluid flow behavior inside a wellbore. This study aims to simulate gas-liquid flow inside horizontal eccentric annulus using an Eulerian-Eulerian computational fluid dynamics (CFD) model for two-phase flow patterns i.e., dispersed bubble, dispersed annular, plug, slug, churn, wavy annular. To perform experiments using air-water mixtures for various in-situ air and water flow rates, a flow loop was constructed. A digital high speed camera is used for recording each test dynamically for identification of the liquid holdup and flow patterns. Results showed that CFD model predicts frictional pressure losses with an error less than 20% for all two-phase flow patterns when compared with experimental data.


Author(s):  
Kohei Nago ◽  
Yasuo Koizumi ◽  
Akihiro Uchibori ◽  
Hiroyuki Ohshima

A two dimensional air jet was blown out from a nozzle into water in a thin vessel. The behavior of the interface between water and the air jet and also the air jet were recorded with a high speed video camera. Filament-like ears and wisps pulled-out from the wavy water surface were noticed in the recorded photos. Droplets are formed from these. Droplet diameters were obtained from the recorded photos. As the air velocity increased, the number of droplets created by the air jet increased lineally and the smaller droplets increased. The correlation for the droplet diameter distribution developed for the annular dispersed two-phase flow in a pipe predicted well the present results. The correlations for the droplet diameter developed for the annular dispersed two-phase flow in a pipe and for the jet blowing out from the stagnant water pool considerably underpredict the experimental results.


Author(s):  
Jacqueline Barber ◽  
Khellil Sefiane ◽  
David Brutin ◽  
Lounes Tadrist

Boiling in microchannels remains elusive due to the lack of full understanding of the mechanisms involved. A powerful tool in achieving better comprehension of the mechanisms is detailed imaging and analysis of the two phase flow at a fundamental level. We induced boiling in a single microchannel geometry (hydraulic diameter 727 μm), using a refrigerant FC-72, to investigate several flow patterns. A transparent, metallic, conductive deposit has been developed on the exterior of rectangular microchannels, allowing simultaneous uniform heating and visualisation to be conducted. The data presented in this paper is for a particular case with a uniform heat flux of 4.26 kW/m2 applied to the microchannel and inlet liquid mass flowrate, held constant at 1.33×10−5 kg/s. In conjunction with obtaining high-speed images and videos, sensitive pressure sensors are used to record the pressure drop profiles across the microchannel over time. Bubble nucleation, growth and coalescence, as well as periodic slug flow, are observed in the test section. Phenomena are noted, such as the aspect ratio and Reynolds number of a vapour bubble, which are in turn correlated to the associated pressure drops over time. From analysis of our results, images and video sequences with the corresponding physical data obtained, it is possible to follow visually the nucleation and subsequent both ‘free’ and ‘confined’ growth of a vapour bubble over time.


Author(s):  
Maral Taghva ◽  
Lars Damkilde

To protect a pressurized system from overpressure, one of the most established strategies is to install a Pressure Safety Valve (PSV). Therefore, the excess pressure of the system is relieved through a vent pipe when PSV opens. The vent pipe is also called “PSV Outlet Header”. After the process starts, a transient two-phase flow is formed inside the outlet header consisting of high speed pressurized gas interacting with existing static air. The high-speed jet compresses the static air towards the end tail of the pipe until it is discharged to the ambiance and eventually, the steady state is achieved. Here, this transient process is investigated both analytically and numerically using the method of characteristics. Riemann’s solvers and Godunov’s method are utilized to establish the solution. Propagation of shock waves and flow property alterations are clearly demonstrated throughout the simulations. The results show strong shock waves as well as high transient pressure take place inside the outlet header. This is particularly important since it indicates the significance of accounting for shock waves and transient pressure, in contrast to commonly accepted steady state calculations. More precisely, shock waves and transient pressure could lead to failure, if the pipe thickness is chosen only based on conventional steady state calculations.


Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1166 ◽  
Author(s):  
Shizhen Li ◽  
Wei Li ◽  
Yanjun Liu ◽  
Chen Ji ◽  
Jingzhi Zhang

A two-phase flow ejector is an important part of a water mist fire suppression system, and these devices have become a popular research topic in recent years. This paper proposes a supersonic ejector that aims to improve the efficiency of water mist fire suppression systems. The effects of ejector geometric parameters on the entrainment ratio (ER) were explored. The effects of primary flow pressure (PP) on the mixing process and flow phenomena were studied by a high-speed camera. The experimental results show that the ER first increases and then decreases with increasing PP. ER increases with increasing ejector area ratio (AR). The PP corresponding to the maximum ER of ejectors with a different nozzle exit position (NXP) is 3.6 bar. The ejector with an NXP of +1 and AR of 6 demonstrate the best performance, and the ER of this ejector reaches 36.29. The spray half-cone angle of the ejector increases with increasing ER, reaching a maximum value of 7.07°. The unstable atomization half-cone angle is mainly due to a two-phase flow pulsating phenomenon. The pulsation period is 10 ms. In the present study, a general rule that provides a reference for ejector design and selection was obtained through experiments.


1998 ◽  
Vol 1 (1) ◽  
pp. 7-7 ◽  
Author(s):  
G. H. Schnerr ◽  
S. Adam

2008 ◽  
Author(s):  
Mohammad A. Rahman ◽  
Johana Gomez ◽  
Ted Heidrick ◽  
Brian A. Fleck ◽  
Jennifer McMillan

Experimentally accurate void fraction measurements are a challenge in an air/water, two-phase flows through an industrial nozzle assembly, as a highly non-uniform void fraction exists in the feeding conduit prior to the nozzle. In this study, average void fractions were measured by isolating a section in the feeding conduit of a horizontal nozzle assembly, termed as the quick-closing-valve (QCV) technique. A high-speed video camera was utilized to capture the asynchronization closing time, tac. The average closing time and asynchronization for the pneumatically controlled valves were 200 ms and 2 ms, respectively. Based on the equation of 100umtac (1−α)/αlc, the synchronization error between the two valves was 1.12%, 1.26%, and 1.79% for the 1%, 2% and 4% ALR cases, respectively; here um is the mixture velocity, α is the void faction, and lc is the closing length. Higher synchronization error at 4% ALR occurs due to enhanced momentum in the flow regime. Experimental results indicate that the average α over the 33.4 cm feeding conduit (6.25 mm ID) was 76% (αtheoretical = 75%) for the 2% ALR, and 85% (αtheoretical = 83%) for the 3.3% ALR. In the two-phase, two-component flow the α affects the drop size and stability of the spray produced from an industrial nozzle assembly. Learning from this study will yield insights and conceptual understanding of two-phase flow phenomena in conduit, which would affect stability, pulsation tendency, and possibly atomization performance of the nozzle downstream. Two-phase flow nozzles have wide applications in the industries, e.g. petrochemical, pharmaceutical, and others.


1985 ◽  
Vol 25 (1) ◽  
pp. 107
Author(s):  
Kathryn J. Fagg

Gas lift has proved a most effective artificial lift method for the fields operated by Esso Australia Ltd in Bass Strait for the Esso-BHP joint venture. Gas lift is now used to produce approximately 5 st ML/d of the total crude production from the Strait. It has enabled wells to be produced to water cuts higher than 90 per cent, increasing the oil recovery from the fields by up to 35 per cent.Gas lift work in Bass Strait to date has included the use of special packoff gas lift assemblies for wells with sliding sleeves, the development of a tool to assist the opening of the sleeves, improved operating techniques to limit slugging from gas-lifted wells, and the testing of gas lift performance. Gas lifting has been more successful than expected, and as a result, workovers initially planned to install full gas lift strings for older wells have not been necessary. The two phase flow correlations available have been improved to match the performance of the gas-lifted wells. The correlations are now used to design tubing strings with a number of gas lift mandrels prior to running the initial completions and to select the optimum gas injection depth.Future work in gas lift for Bass Strait will involve the optimisation and automation of lift gas distribution on the platforms. Gas lift will also be used for planned future developments, including mini-platforms and subsea completions.


Author(s):  
Yumin Xiao ◽  
R. S. Amano ◽  
Timin Cai ◽  
Jiang Li

Abstract In solid rocket motors (SRMS) using aluminized composite solid propellants and submerged nozzles a two-phase flow pattern is one of the main flow characteristics needs to be investigated. The modeling and validation of two-phase flow are the focus in this research field. In this paper the authors first traced the particle trajectory in a SRM chamber by using numerical method, and then developed a new experimental method to measure the particle trajectory in a SRM chamber to validate the numerical results. The experimental method was based on the RTR (X-ray Real-time Radiography) technique and high-speed motion analyzer. A special method was developed to imitate the particle injection on the propellant surface. The calculation results and measurement data show that the trajectory obtained by numerical simulation was in good agreement with the measured one by imposing proper boundary conditions. For particles with diameter of 75μm, the initial velocity factor of particle is approximately 0.4, and the particles pass through the centerline in both calculation and experiment. The present method can be extended to study the impingement of particles on the wall and other related two-phase flow patterns.