Film Cooling With Swirling Coolant Flow on a Flat Plate and the Endwall of High-Loaded First Nozzle

Author(s):  
Kenichiro Takeishi ◽  
Yutaka Oda ◽  
Shinpei Kondo

This paper describes an experimental study on the film cooling effectiveness of circular and fan-shaped film cooling holes with a swirling film coolant injected through a flat plate and the endwall of a high-loaded first nozzle. The experiments were conducted using a flat plate wind tunnel and a two-dimensional vane cascade, which is designed based on the first-stage vane of an Energy Efficient Engine (E3) studied under a NASA project. The film cooling effectiveness on a flat plate wind tunnel and the endwall of the enlarged first nozzle of the E3 turbine was measured using pressure sensitive paint (PSP) techniques. The experimental results indicate that the film cooling effectiveness of a circular hole improved by increasing the angle θ of two impinging jets inside the cavity, which are used both for cooling the internal wall and generating a swirling motion in the film coolant. In contrast, it was found that there exist optimal jet angles of θ = 20° for a circular film cooling hole, θ = 5–10° for a flat plate wind tunnel test, and θ = 15° for the cascade test conducted using a fan-shaped film cooling hole. Thus the new film cooling method using swirling cooling air has been demonstrated to maintain high film cooling effectiveness even under such a complicated flow field.

2019 ◽  
Vol 141 (3) ◽  
Author(s):  
Dale W. Fox ◽  
Fraser B. Jones ◽  
John W. McClintic ◽  
David G. Bogard ◽  
Thomas E. Dyson ◽  
...  

Most studies of turbine airfoil film cooling in laboratory test facilities have used relatively large plenums to feed flow into the coolant holes. However, a more realistic inlet condition for the film cooling holes is a relatively small channel. Previous studies have shown that the film cooling performance is significantly degraded when fed by perpendicular internal crossflow in a smooth channel. In this study, angled rib turbulators were installed in two geometric configurations inside the internal crossflow channel, at 45 deg and 135 deg, to assess the impact on film cooling effectiveness. Film cooling hole inlets were positioned in both prerib and postrib locations to test the effect of hole inlet position on film cooling performance. A test was performed independently varying channel velocity ratio and jet to mainstream velocity ratio. These results were compared to the film cooling performance of previously measured shaped holes fed by a smooth internal channel. The film cooling hole discharge coefficients and channel friction factors were also measured for both rib configurations with varying channel and inlet velocity ratios. Spatially averaged film cooling effectiveness is largely similar to the holes fed by the smooth internal crossflow channel, but hole-to-hole variation due to inlet position was observed.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Marc Fraas ◽  
Tobias Glasenapp ◽  
Achmed Schulz ◽  
Hans-Jörg Bauer

Internal coolant passages of gas turbine vanes and blades have various orientations relative to the external hot gas flow. As a consequence, the inflow of film cooling holes varies as well. To further identify the influencing parameters of film cooling under varying inflow conditions, the present paper provides detailed experimental data. The generic study is performed in a novel test rig, which enables compliance with all relevant similarity parameters including density ratio. Film cooling effectiveness as well as heat transfer of a 10–10–10 deg laidback fan-shaped cooling hole is discussed. Data are processed and presented over 50 hole diameters downstream of the cooling hole exit. First, the parallel coolant flow setup is discussed. Subsequently, it is compared to a perpendicular coolant flow setup at a moderate coolant channel Reynolds number. For the perpendicular coolant flow, asymmetric flow separation in the diffuser occurs and leads to a reduction of film cooling effectiveness. For a higher coolant channel Reynolds number and perpendicular coolant flow, asymmetry increases and cooling effectiveness is further decreased. An increase in blowing ratio does not lead to a significant increase in cooling effectiveness. For all cases investigated, heat transfer augmentation due to film cooling is observed. Heat transfer is highest in the near-hole region and decreases further downstream. Results prove that coolant flow orientation has a severe impact on both parameters.


Author(s):  
Zhongran Chi ◽  
Chang Han ◽  
Xueying Li ◽  
Jing Ren ◽  
Hongde Jiang

A tripod cylindrical film hole with asymmetric side holes is studied numerically and experimentally on a flat plate for higher film cooling effectiveness. Firstly, the influences of geometrical parameters are studied and the optimum configurations of the asymmetric tripod hole are found in a DoE optimization study based on an improved numerical model for film cooling prediction, in which more than one hundred 3D CFD simulations are carried out. Then one optimum configuration of the asymmetric tripod hole is examined experimentally using pressure-sensitive paint (PSP) measurements, and compared against the experimental results of the simple cylindrical film hole and a well-designed shaped film hole. The flow and heat transfer characteristics of the asymmetric tripod holes were explored from the DoE results. The side holes can form a shear vortex system or an anti-kidney vortex system when proper spanwise distances of them are adopted, which laterally transports the coolant and form a favorable coolant coverage. According to the experimental results, the cooling performance of the optimized asymmetric tripod hole is significantly better than that of the simple cylindrical hole, especially at high blowing ratios. And the optimized asymmetric tripod hole can provide almost the same or even higher film cooling effectiveness on the flat plate compared with the shaped hole in the same flow conditions.


Author(s):  
K. Vighneswara Rao ◽  
Jong S. Liu ◽  
Daniel C. Crites ◽  
Luis A. Tapia ◽  
Malak F. Malak ◽  
...  

In this study, cylindrical and fan shaped film cooling holes are evaluated on the blade surface numerically, using the Computational Fluid Dynamics (CFD) tool ANSYS-CFX, with the objective of improving cooling effectiveness by understanding the flow pattern at the cooling hole exit. The coolant flow rates are adjusted for blowing ratios of 0.5, 1.0 & 1.5 (momentum flux ratios of 0.125, 0.5 & 1.125 respectively). The density ratio is maintained at 2.0. New shaped holes viz. straight, concave and convex trench holes are introduced and are evaluated under similar operating conditions. Results are presented in terms of surface temperatures and adiabatic effectiveness at three different blowing ratios for the different film cooling hole shapes analyzed. Comparison is made with reference to the fan shaped film cooling hole to bring out relative merits of different shapes. The new trench holes improved the film cooling effectiveness by allowing more residence time for coolant to spread laterally while directing smoothly onto the airfoil surface. While convex trench improved the centre-line effectiveness, straight trench improved the laterally-averaged and overall effectiveness at all blowing ratios. Concave trench improved the effectiveness at blowing ratios 0.5 and 1.0.


2009 ◽  
Vol 131 (4) ◽  
Author(s):  
Zhihong Gao ◽  
Diganta Narzary ◽  
Je-Chin Han

This paper is focused on the effect of film-hole configurations on platform film cooling. The platform is cooled by purge flow from a simulated stator-rotor seal combined with discrete-hole film cooling within the blade passage. The cylindrical holes and laidback fan-shaped holes are assessed in terms of film-cooling effectiveness and total pressure loss. Lined up with the freestream streamwise direction, the film holes are arranged on the platform with two different layouts. In one layout, the film-cooling holes are divided into two rows and more concentrated on the pressure side of the passage. In the other layout, the film-cooling holes are divided into four rows and loosely distributed on the platform. Four film-cooling hole configurations are investigated totally. Testing was done in a five-blade cascade with medium high Mach number condition (0.27 and 0.44 at the inlet and the exit, respectively). The detailed film-cooling effectiveness distributions on the platform were obtained using pressure sensitive paint technique. Results show that the combined cooling scheme (slot purge flow cooling combined with discrete-hole film cooling) is able to provide full film coverage on the platform. The shaped holes present higher film-cooling effectiveness and wider film coverage than the cylindrical holes, particularly at higher blowing ratios. The hole layout affects the local film-cooling effectiveness. The shaped holes also show the advantage over the cylindrical holes with lower total pressure loss.


Author(s):  
Sebastian Schulz ◽  
Simon Maier ◽  
Jeffrey P. Bons

In an attempt to abate the detrimental jet vorticity and lift-off effects at high blowing ratios, the objective of the present study is to investigate the impact of an anti-vortex film cooling hole design on the film cooling effectiveness and the secondary flow field. Furthermore, the influence of low and high turbulence levels is studied with Tu ≈ .0.7% and ≈ 10%, respectively. For the experiments infrared thermography and particle image velocimetry (PIV) are employed. The experiments are conducted in a subsonic wind tunnel at a Reynolds number of 11000 based on the film cooling hole diameter. A flat plate model with an array of three cylindrical primary holes with secondary offshoots to each side represents the anti-vortex geometry. The cylindrical hole arrangement with a diameter of 17.5 mm is inclined at 30° in streamwise direction, with the anti-vortex holes branching off from the primary hole base in a 21° angle. Information from a flat plate with six cylindrical holes of 17.5 mm in diameter inclined at 30 in streamwise direction is used as baseline for comparison. The primary hole spacing was 4.75 and 3 hole diameters, respectively. Results are presented for blowing ratios of 1 and 2 with a constant density ratio of 1.1. The PIV measurements are taken in two planes perpendicular to the flow direction to record the secondary flow structures. The results of the infrared thermography show a strong decrease in film cooling effectiveness as high turbulence levels occur, especially for low blowing ratios. For higher blowing ratios low and high turbulence levels have similar effects on film cooling effectiveness. A significant improvement in film cooling performance is displayed by the anti-vortex design over the standard circular hole arrangement for every blowing ratio. The effectiveness results reveal an improved lateral spreading of the coolant with coolant jets staying attached throughout the series of experiments. By remaining inside the boundary layer, the effects of a high turbulent freestream on film cooling performance is less. The PIV results unveil information of a new vortex pair on either side of the primary hole kidney vortex. Especially at high blowing ratios the results indicate, that the anti-vortex hole design promotes the interaction between the vortical structures, explaining the increased lateral film effectiveness results. The factor which lends to the superior performance and credibility of the studied anti-vortex design is that the results are obtained for 35% less mass flow than the baseline.


Author(s):  
Zhihong Gao ◽  
Diganta Narzary ◽  
Je-Chin Han

This paper is focused on the effect of film hole configurations on platform film cooling. The platform is cooled by purge flow from a simulated stator-rotor seal combined with discrete-hole film cooling within the blade passage. The cylindrical holes and laidback fan-shaped holes are assessed in terms of film cooling effectiveness and total pressure loss. Lined up with the freestream streamwise direction, the film holes are arranged on the platform with two different layouts. In one layout, the film cooling holes are divided into two rows and more concentrated on the pressure side of the passage. In the other layout, the film cooling holes are divided into four rows and loosely distributed on the platform. Four film cooling hole configurations are investigated totally. Testing was done in a five-blade cascade with medium high Mach number condition (0.27 and 0.44 at the inlet and the exit, respectively). The detailed film cooling effectiveness distributions on the platform was obtained using pressure sensitive paint (PSP) technique. Results show that the combined cooling scheme (slot purge flow cooling combined with discrete hole film cooling) is able to provide full film coverage on the platform. The shaped holes present higher film cooling effectiveness and wider film coverage than the cylindrical holes, particularly at higher blowing ratios. The hole layout affects the local film cooling effectiveness. The shaped holes also show the advantage over the cylindrical holes with lower total pressure loss.


Author(s):  
Sang Hyun Oh ◽  
Dong Hyun Lee ◽  
Kyung Min Kim ◽  
Moon Young Kim ◽  
Hyung Hee Cho

An experimental investigation is conducted on the cooling effectiveness of full-coverage film cooled wall with impingement jets. Film cooling plate is made of stainless steel, thus the adiabatic film cooling effectiveness and the cooling effect of impingement jet underneath the film cooling plate are comprised in the cooling effectiveness. Infra-red camera is used to measure the temperature of film cooled surfaces. Experiments are conducted with different film cooling hole angles, such as 35° and 90°. Diameters of both film cooling holes and impinging jet holes are 5 mm. The jet Reynolds number base on the hole diameter (Red) ranges from 3,000 to 5,000 and equivalent blowing ratios (M) varies from 0.3 to 0.5, respectively. The distance between the injection plate and the film cooling plate is 1, 3 and 5 times of the hole diameter. The streamwise and spanwise hole spacing to the hole diameter ratio (p/d) are 3 for both the film cooling hole plate and the impingement jet hole plate. The 35° angled film cooling hole arrangement shows higher film cooling effectiveness than the 90° film cooling hole arrangement. As the blowing ratio increases, the cooling effectiveness is enhanced for both the 35° almost constant regardless of H/d, while H/d = 1 shows a minimum value for the angled film cooling hole.


Author(s):  
Travis B. Watson ◽  
Kyle R. Vinton ◽  
Lesley M. Wright ◽  
Daniel C. Crites ◽  
Mark C. Morris ◽  
...  

Abstract The effect of film cooling hole inlet geometry is experimentally investigated in this study. Detailed film cooling effectiveness distributions are obtained on a flat plate using Pressure Sensitive Paint (PSP). The inlet of a traditional 12°-12°-12°, laidback, fanshaped hole varies from a traditional “round” opening to an oblong, racetrack shaped opening. In this study, a single racetrack inlet with an aspect ratio of 2:1 is compared to the round inlet. For both designs, the holes are inclined at θ = 30° relative to the mainstream. Blowing ratios of 0.5, 1.0, and 1.5 are considered as the coolant–to–mainstream density ratio varies between 1.0 and 4.0. For all cases, the freestream turbulence intensity is maintained at 7.5%. With the introduction of the racetrack shaped inlet, the coolant spreads laterally across the diffuse, laidback fanshaped outlet. The centerline film cooling effectiveness is reduced with the enhanced lateral spread of the coolant. However, the benefit of the shaped inlet is also observed with an increase in the area averaged film cooling effectiveness, compared to the traditional round inlet. Not only does the shaped inlet promote spreading of the coolant, it is also believed the racetrack shape suppresses turbulence within the hole allowing for enhanced film cooling protection near the film cooling holes.


2018 ◽  
Vol 140 (12) ◽  
Author(s):  
Jiaxu Yao ◽  
Jin Xu ◽  
Ke Zhang ◽  
Jiang Lei ◽  
Lesley M. Wright

The interaction of flow and film-cooling effectiveness between jets of double-jet film-cooling (DJFC) holes on a flat plate is studied experimentally. The time-averaged flow field in several axial positions (X/d = −2.0, 1.0, and 5.0) is obtained through a seven-hole probe. The downstream film-cooling effectiveness on the flat plate is measured by pressure sensitive paint (PSP). The inclination angle (θ) of all the holes is 35 deg, and the compound angle (β) is ±45 deg. Effects of the spanwise distance (p = 0, 0.5d, 1.0d, 1.5d, and 2.0d) between the two interacting jets of DJFC holes are studied, while the streamwise distance (s) is kept as 3d. The blowing ratio (M) varies as 0.5, 1.0, 1.5, and 2.0. The density ratio (DR) is maintained at 1.0. Results show that the interaction between the two jets of DJFC holes has different effects at different spanwise distances. For a small spanwise distance (p/d = 0), the interaction between the jets presents a pressing effect. The downstream jet is pressed down and kept attached to the surface by the upstream one. The effectiveness is not sensitive to blowing ratios. For mid-spanwise distances (p/d = 0.5 and 1.0), the antikidney vortex pair dominates the interaction and pushes both of the jets down, thus leading to better coolant coverage and higher effectiveness. As the spanwise distance becomes larger (p/d ≥ 1.5), the pressing effect almost disappears, and the antikidney vortex pair effect is weaker. The jets separate from each other and the coolant coverage decreases. At a higher blowing ratio, the interaction between the jets of DJFC holes happens later.


Sign in / Sign up

Export Citation Format

Share Document