Low NOx SEV Lean Premix Reheat Combustion in Alstom GT24 Gas Turbines

Author(s):  
Daniel Guyot ◽  
Gabrielle Tea ◽  
Christoph Appel

Reducing gas turbine emissions and increasing their operational flexibility are key targets in today’s gas turbine market. In order to further reduce emissions and increase the operational flexibility of its GT24 (60Hz) and GT26 (50Hz), Alstom has introduced an improved SEV burner and fuel lance into its GT24 upgrade 2011 and GT26 upgrade 2011 sequential reheat combustion system. Sequential combustion is a key differentiator of Alstom GT24 engines in the F-class gas turbine market. The inlet temperature for the GT24 SEV combustor is around 1000 degC and reaction of the fuel/oxidant mixture is initiated through auto-ignition. The recent development of the Alstom sequential combustion system is a perfect example of evolutionary design optimizations and technology transfer between Alstom GT24 and GT26 engines. Better overall performance is achieved through improved SEV burner aerodynamics and fuel injection, while keeping the main features of the sequential burner technology. The improved SEV burner/lance concept has been optimized towards rapid fuel/oxidant mixing for low emissions, improved fuel flexibility with regards to highly reactive fuels (higher C2+ and hydrogen content), and to sustain a wide operation window. In addition, the burner front panel features an improved cooling concept based on near-wall cooling as well as integrated acoustics damping devices designed to reduce combustion pulsations thus extending the SEV combustor’s operation window even further. After having been validated extensively in the Alstom high pressure sector rig test facility, the improved GT24 SEV burner has been retrofitted into a commercial GT24 field engine for full engine validation during long-term operation. This paper presents the obtained high pressure sector rig and engine validation results for the GT24 (2011) SEV burner/lance hardware with a focus on reduced NOX and CO emissions and improved operational behavior of the SEV combustor. The high pressure tests demonstrated robust SEV burner/lance operation with up to 50% lower NOX formation and a more than 70K higher SEV burner inlet temperature compared to the GT24 (2006) hardware. For the GT24 engine with retrofitted upgrade 2011 SEV burner/lance all validation targets were achieved including an extremely robust operation behavior, up to 40% lower GT NOX emissions, significantly lower CO emissions at partload and baseload, a very broad operation window (up to 100K width in SEV combustor inlet temperature) and all measured SEV burner/lance temperatures in the expected range. Sector rig and engine validation results have confirmed the expected SEV burner fuel flexibility (up to 18%-vol. C2+ and up to 5%-vol. hydrogen as standard).

Author(s):  
Daniel Guyot ◽  
Gabrielle Tea ◽  
Christoph Appel

Reducing gas turbine emissions and increasing their operational flexibility are key targets in today's gas turbine market. In order to further reduce emissions and increase the operational flexibility of its GT24 (60 Hz) and GT26 (50 Hz), Alstom has introduced an improved sequential environmental (SEV) burner and fuel lance into its GT24 and GT26 upgrades 2011 sequential reheat combustion system. Sequential combustion is a key differentiator of Alstom GT24/GT26 engines in the F-class gas turbine market. The inlet temperature for the SEV combustor is around 1000 °C and reaction of the fuel/oxidant mixture is initiated through auto-ignition. The recent development of the Alstom sequential combustion system is a perfect example of evolutionary design optimizations and technology transfer between Alstom GT24 and GT26 engines. Better overall performance is achieved through improved SEV burner aerodynamics and fuel injection, while keeping the main features of the sequential burner technology. The improved SEV burner/lance concept has been optimized toward rapid fuel/oxidant mixing for low emissions, improved fuel flexibility with regard to highly reactive fuels (higher C2+ and hydrogen content), and to sustain a wide operation window. The burner front panel features an improved cooling concept based on near-wall cooling as well as integrated acoustics damping devices designed to reduce combustion pulsations, thus extending the SEV combustor's operation window even further. After having been validated extensively in Alstom's high pressure (HP) sector rig test facility, the improved GT24 SEV burner has been retrofitted into a commercial GT24 field engine for full engine validation during long-term operation. This paper presents the obtained HP sector rig and engine validation results for the GT24 (2011) SEV burner/lance hardware with a focus on reduced NOx and CO emissions and improved operational behavior of the SEV combustor. The HP tests demonstrated robust SEV burner/lance operation with up to 50% lower NOx formation and a more than 70 K higher SEV burner inlet temperature compared to the GT24 (2006) hardware. For the GT24 engine with retrofitted upgrade 2011 SEV burner/lance, all validation targets were achieved including an extremely robust operation behavior, up to 40% lower GT NOx emissions, significantly lower CO emissions at partload and baseload, a very broad operation window (up to 100 K width in SEV combustor inlet temperature), and all measured SEV burner/lance temperatures in the expected range. Sector rig and engine validation results have confirmed the expected SEV burner fuel flexibility (up to 18 vol. % C2+ and up to 5 vol. % hydrogen as standard).


Author(s):  
Hasan Karim ◽  
Jayaprakash Natarajan ◽  
Venkat Narra ◽  
Jun Cai ◽  
Shreekrishna Rao ◽  
...  

Driven by global warming, a relentless march towards increased fuel efficiency has resulted in increased firing temperature for HA-class engines without an increase in baseload emissions. Moreover, emissions compliance for CO, NOx, and unburned hydrocarbons are desired over increased range in gas turbine load. In addition, exceptional gas turbine operational flexibility is desired to address potential intermittency due to the penetration of renewables in the electrical grid. Staged/sequential combustion is a state of the technology to provide operational flexibility and reduced emissions in power generation gas turbines. GE Power’s 7HA-class gas turbine combustion system combines GE’s proven DLN-2.6+ combustion technology, that has run reliably for over 1.3 million fired hours across more than eighty 9FA.03, 9F.05 & 7FA gas turbine engines, with an axially fuel staged system (AFS). Axially staging combustion to two zones allows for increased firing temperature at baseload (while maintaining the same NOx level) by operating the later/second stage hotter than the first/primary stage. During low load operation as the gas turbine firing temperature is reduced, percentage fuel split in the staged fuel system can either be reduced significantly or turned off and thereby keeping the overall combustion system into emissions compliance over a wider range of firing temperatures. This paper presents both the development testing of the staged combustion in the FA and HA class gas turbine combustion system rigs at GE Power’s Gas Turbine Technology Laboratory and the validation testing of staged combustion system for the 7HA.01 engine completed during Spring 2016 at GE Power’s engine test facility in Greenville, SC. The paper also discusses the significant simplification of operational principle and flexibility of startup, loading and baseload operation of the 7HA combustion system. Discussion of engine test results will show how axial fuel staging was utilized to demonstrate emissions compliance ( NOx (15% O2) < 25 ppm; CO < 9 ppm), operation from 14% load to 100% load with low combustion dynamics and also to enable wide wobbe capability, which is a normalized measure of fuel flexibility.


Author(s):  
Frank Reiss ◽  
Sven-Hendrik Wiers ◽  
Ulrich Orth ◽  
Emil Aschenbruck ◽  
Martin Lauer ◽  
...  

This paper describes the development and test results of the low emission combustion system for the new industrial gas turbines in the 6–7 MW class from MAN Diesel & Turbo. The design of a robust combustion system and the achievement of very low emission targets were the most important design goals of the combustor development. During the design phase, the analysis of the combustor (i.e. burner design, air distribution, liner cooling design) was supported with different CFD tools. This advanced Dry Low Emission can combustion system (ACC) consists of 6 cans mounted externally on the gas turbine. The behavior and performance of a single can sector was tested over a wide load range and with different boundary conditions; first on an atmospheric test rig and later on a high pressure test rig with extensive instrumentation to ensure an efficient test campaign and accurate data. The atmospheric tests showed a very good performance for all combustor parts and promising results. The high pressure tests demonstrated very stable behavior at all operation modes and very low emissions to satisfy stringent environmental requirements. The whole operation concept of the combustion system was tested first on the single-can high pressure test bed and later on twin and single shaft gas turbines at MAN’s gas turbine test facility. During the engine tests, the can combustors demonstrated the expected combustion performance under real operation conditions. All emissions and performance targets were fully achieved. On the single shaft engine, the combustors were running with single digit ppm NOx levels between 50% and 100% load. The validation phase and further optimization of the gas turbines and the engine components are ongoing. The highlights of the development process and results of the combustor and engine tests will be presented and discussed within this paper.


Author(s):  
Douglas A. Pennell ◽  
Mirko R. Bothien ◽  
Andrea Ciani ◽  
Victor Granet ◽  
Ghislain Singla ◽  
...  

This paper introduces and presents validation of the Constant Pressure Sequential Combustion system (denoted CPSC), a second generation concept developed for and applied to the new Ansaldo GT36 H-class gas turbine combustors. It has evolved from the well-established sequential burner technology applied to all current GT26 and GT24 gas turbines, and contains all architectural improvements implemented since original inception of this engine frame in 1994, with beneficial effects on the operation turndown, fuel flexibility, on the overall system robustness, and featuring the required aspects to stay competitive in the present day energy market. The applied air and fuel management therefore facilitate emission and dynamics control at both the extremely high and low firing temperature ranges required for existing and future Ansaldo gas turbine engine classes.


2021 ◽  
Author(s):  
Takashi Nishiumi ◽  
Hirofumi Ohara ◽  
Kotaro Miyauchi ◽  
Sosuke Nakamura ◽  
Toshishige Ai ◽  
...  

Abstract In recent years, MHPS achieved a NET M501J gas turbine combined cycle (GTCC) efficiency in excess of 62% operating at 1,600°C, while maintaining NOx under 25ppm. Taking advantage of our gas turbine combustion design, development and operational experience, retrofits of earlier generation gas turbines have been successfully applied and will be described in this paper. One example of the latest J-Series technologies, a conventional pilot nozzle was changed to a premix type pilot nozzle for low emission. The technology was retrofitted to the existing F-Series gas turbines, which resulted in emission rates of lower than 9ppm NOx(15%O2) while maintaining the same Turbine Inlet Temperature (TIT: Average Gas Temperature at the exit of the transition piece). After performing retrofitting design, high pressure rig tests, the field test prior to commercial operation was conducted on January 2019. This paper describes the Ultra-Low NOx combustor design features, retrofit design, high pressure rig test and verification test results of the upgraded M501F gas turbine. In addition, it describes another upgrade of turbine to improve efficiency and of combustion control system to achieve low emissions. Furthermore it describes the trouble-free upgrade of seven (7) units, which was completed by utilizing MHPS integration capabilities, including handling all the design, construction and service work of the main equipment, plant and control systems.


Author(s):  
Katsuyoshi Tada ◽  
Kei Inoue ◽  
Tomo Kawakami ◽  
Keijiro Saitoh ◽  
Satoshi Tanimura

Gas-turbine combined-cycle (GTCC) power generation is clean and efficient, and its demand will increase in the future from economic and social perspectives. Raising turbine inlet temperature is an effective way to increase combined cycle efficiency and contributes to global environmental conservation by reducing CO2 emissions and preventing global warming. However, increasing turbine inlet temperature can lead to the increase of NOx emissions, depletion of the ozone layer and generation of photochemical smog. To deal with this issue, MHPS (MITSUBISHI HITACHI POWER SYSTEMS) and MHI (MITSUBISHI HEAVY INDUSTRIES) have developed Dry Low NOx (DLN) combustion techniques for high temperature gas turbines. In addition, fuel flexibility is one of the most important features for DLN combustors to meet the requirement of the gas turbine market. MHPS and MHI have demonstrated DLN combustor fuel flexibility with natural gas (NG) fuels that have a large Wobbe Index variation, a Hydrogen-NG mixture, and crude oils.


Author(s):  
Mirko R. Bothien ◽  
Andrea Ciani ◽  
John P. Wood ◽  
Gerhard Fruechtel

Abstract Excess energy generation from renewables can be conveniently stored as hydrogen for later use as a gas turbine fuel. Also, the strategy to sequestrate CO2 from natural gas (NG) will require gas turbines to run with hydrogen-based fuels. In such scenarios, high temperature low emission combustion of hydrogen is a key requirement for the future gas turbine market. Ansaldo Energia's gas turbines featuring sequential combustion have an intrinsic advantage when it comes to fuel flexibility and in particular hydrogen-based fuels. The sequential combustion system is composed of two complementary combustion stages in series: one premix stage followed by an auto-ignited second stage overcoming the limits of traditional premix combustion systems through a highly effective extra tuning parameter, i.e., the temperature between the first and the second stage. The standard constant pressure sequential combustion (CPSC) system as applied in the GT36 engine is tested, at high pressure, demonstrating that a modified operation concept allows stable combustion with no changes in combustor hardware for the whole range of NG and hydrogen blends. It is shown that in the range from 0% to 70% (vol.) hydrogen, stable combustion is achieved at full nominal exit temperature, i.e., without any derating and thus clearly outperforming other available conventional premixed combustors. Operation between 70% and 100% is possible as well and only requires a mild reduction of the combustor exit temperature. By proving the transferability of the single-can high pressure results to the engine, this paper demonstrates the practicality of operating the Ansaldo Energia GT36 H-Class gas turbine on fuels containing unprecedented concentrations of hydrogen while maintaining excellent performance and low emissions both in terms of NOx and CO2.


Author(s):  
Y. Wang ◽  
L. Reh ◽  
D. Pennell ◽  
D. Winkler ◽  
K. Döbbeling

Stationary gas turbines for power generation are increasingly being equipped with low emission burners. By applying lean premixed combustion techniques for gaseous fuels both NOx and CO emissions can be reduced to extremely low levels (NOx emissions <25vppm, CO emissions <10vppm). Likewise, if analogous premix techniques can be applied to liquid fuels (diesel oil, Oil No.2, etc.) in gas-fired burners, similar low level emissions when burning oils are possible. For gas turbines which operate with liquid fuel or in dual fuel operation, VPL (Vaporised Premixed Lean)-combustion is essential for obtaining minimal NOx-emissions. An option is to vaporise the liquid fuel in a separate fuel vaporiser and subsequently supply the fuel vapour to the natural gas fuel injection system; this has not been investigated for gas turbine combustion in the past. This paper presents experimental results of atmospheric and high-pressure combustion tests using research premix burners running on vaporised liquid fuel. The following processes were investigated: • evaporation and partial decomposition of the liquid fuel (Oil No.2); • utilisation of low pressure exhaust gases to externally heat the high pressure fuel vaporiser; • operation of ABB premix-burners (EV burners) with vaporised Oil No.2; • combustion characteristics at pressures up to 25bar. Atmospheric VPL-combustion tests using Oil No.2 in ABB EV-burners under simulated gas turbine conditions have successfully produced emissions of NOx below 20vppm and of CO below 10vppm (corrected to 15% O2). 5vppm of these NOx values result from fuel bound nitrogen. Little dependence of these emissions on combustion pressure bas been observed. The techniques employed also ensured combustion with a stable non luminous (blue) flame during transition from gaseous to vaporised fuel. Additionally, no soot accumulation was detectable during combustion.


Author(s):  
Ralph A. Dalla Betta ◽  
James C. Schlatter ◽  
Sarento G. Nickolas ◽  
Martin B. Cutrone ◽  
Kenneth W. Beebe ◽  
...  

The most effective technologies currently available for controlling NOx emissions from heavy-duty industrial gas turbines are either diluent injection in the combustor reaction zone, or lean premixed Dry Low NOx (DLN) combustion. For ultra low emissions requirements, these must be combined with selective catalytic reduction (SCR) DeNOx systems in the gas turbine exhaust. An alternative technology for achieving comparable emissions levels with the potential for lower capital investment and operating cost is catalytic combustion of lean premixed fuel and air within the gas turbine. The design of a catalytic combustion system using natural gas fuel has been prepared for the GE model MS9OOIE gas turbine. This machine has a turbine inlet temperature to the first rotating stage of over 1100°C and produces approximately 105 MW electrical output in simple cycle operation. The 508 mm diameter catalytic combustor designed for this gas turbine was operated at full-scale conditions in tests conducted in 1992 and 1994. The combustor was operated for twelve hours during the 1994 test and demonstrated very low NOx emissions from the catalytic reactor. The total exhaust NOx level was approximately 12–15 ppmv and was produced almost entirely in the preburner ahead of the reactor. A small quantity of steam injected into the preburner reduced the NOx emissions to 5–6 ppmv. Development of the combustion system has continued with the objectives of reducing CO and UHC emissions, understanding the parameters affecting reactor stability and spatial non-uniformities which were observed at low inlet temperature, and improving the structural integrity of the reactor system to a level required for commercial operation of gas turbines. Design modifications were completed and combustion hardware was fabricated for additional full-scale tests of the catalytic combustion system in March 1995 and January 1996. This paper presents a discussion of the combustor design, the catalytic reactor design and the results of full-scale testing of the improved combustor at MS9OOIE cycle conditions in the March 1995 and January 1996 tests. Major improvements in performance were achieved with CO and UHC emissions of 10 ppmv and 0 ppmv at base load conditions. This ongoing program will lead to two additional full-scale combustion system tests in 1996. The results of these tests will be available for discussion at the June 1996 Conference in Birmingham.


Author(s):  
Martin Zajadatz ◽  
Douglas Pennell ◽  
Stefano Bernero ◽  
Bettina Paikert ◽  
Raffaele Zoli ◽  
...  

Increasing public awareness and more stringent legislation on pollutants drive gas turbine manufacturers to develop combustion systems with low NOx emissions. In combination to this demand the gas turbines have to provide a broad range of operational flexibility to cover variations in gas composition and ambient conditions as well as varying daily and seasonal energy demands and load profiles. This paper describes the development and implementation of the Alstom AEV (Advanced EnVironmental) burner, an evolution of the EV. Continuous fuel supply to two fuel stages at any engine load simplifies the operation and provides a fast and reliable response of the combustion system during transient operation of the gas turbine. Increased turndown with low emissions is an additional advantage of the combustion system upgrade.


Sign in / Sign up

Export Citation Format

Share Document