Numerical Study of Flow Control in a Diffuser by Vibration Wall and Mechanism Analysis by Establishment of a Nonlinear Simplified Model

Author(s):  
Lu Weiyu ◽  
Huang Guoping ◽  
Fu Xin ◽  
Wang Jinchun ◽  
Hong Shuli

Vibration wall is a kind of important active flow control method, while the interaction between the vibration wall and unsteady separation flow is so complex for researchers to discover the corresponding mechanism. Current researches imply that the better controlled flow is the more ordered flow. At first, the effect of the different control parameters of vibration wall on the total pressure loss was studied by numerical simulation to reveal the control mechanism of vibration wall. Numerical results show that when the vibration frequency reaches the separation vortex frequency, with the amplitude of 0.1 characteristic length, the best flow control is resulted. Furthermore, it can be seen that, the vibration wall with effective parameters can make the large-scale vortices more dominant, while small-scales ones (or clutters) appear less in the pattern. This observation indicates that the flow field tends to be more orderly. Moreover, to further explain this ordering mechanism, a simplified model is established and analyzed, showing that valid external excitement can strengthen the dominated frequency of K-H wave which forms the large-scale separation vortices, and restrains small-scale ones. The flow field is then more orderly and less chaotic, resulting in reduction of flow loss.

Author(s):  
Shawn Aram ◽  
Yu-Tai Lee ◽  
Hua Shan ◽  
Abel Vargas

A numerical study is conducted to explore the unsteady nature of fluidic oscillators which is responsible for generating sweeping jets for effective flow control of large-scale applications. Two- and Three-dimensional (2D and 3D) Unsteady Reynolds-Averaged Navier-Stokes (URANS) and 3D Improved Delayed Detached Eddy Simulation (IDDES) are employed to simulate and resolve the flow structures in the internal flow passages of a fluidic oscillator and external flow field in a quiescent flow condition. The predicted flow generated by an enlarged actuator with an outlet diameter of 25 mm using air as a working fluid is validated against measurements at various supply rates. Comparison of current computational results using 2D and 3D URANS with experiments indicates a reasonable agreement in the jet oscillation frequency. However, a significant discrepancy in the streamwise velocity field is observed between the 2D URANS and experimental data. The 3D URANS also under-predicts the jet width and consequently over-predicts the extension of the jet in the axial direction downstream of the actuator exit. Excellent agreement in the jet oscillation frequency and internal and external flow field is obtained at two supply rates between 3D IDDES and measurements.


2018 ◽  
Vol 140 (4) ◽  
Author(s):  
Xinqian Zheng ◽  
Zhenzhong Sun ◽  
Tomoki Kawakubo ◽  
Hideaki Tamaki

The nonuniformity of the flow field induced by a nonaxisymmetric volute significantly degrades the stability of a turbocharger centrifugal compressor. In this paper, a nonaxisymmetric vaned diffuser is investigated as a nonaxisymmetric flow control method using both three-dimensional computational fluid dynamics (CFD) and experiment. The numerical study first focuses on the relationship between the flow field and the static pressure distortion, and the steady CFD results indicate that the positive static pressure gradient in the rotating direction facilitates flow separation in the vaned diffuser and induces a nonuniform flow field. A nonaxisymmetric flow control method with variable stagger and solidity of the vaned diffuser is developed to suppress the flow separation, and the guideline of the method suggests narrowing flow passages where the flow separates or closing diffuser vanes upstream of flow separations. Steady CFD also presents the flow field of the investigated turbocharger centrifugal compressor with volute, and flow separation is found in the flow passages near the volute tongue. Under the guidance of the nonaxisymmetric flow control method, several nonaxisymmetric vaned diffusers are designed to make the flow field uniform, which are believed to be beneficial for compressor stability. Finally, an experiment is carried out to validate the positive effects of the nonaxisymmetric vaned diffuser for stability improvement. The test data show that Non-AxisVD (with a nonaxisymmetric vaned diffuser) extends the stable flow range (SFR) of the compressor by 26% compared with the AxisVD (with an axisymmetric vaned diffuser), at the cost of acceptable decreases in the maximum total pressure ratio and peak efficiency.


A numerical study on the transition from laminar to turbulent of two-dimensional fuel jet flames developed in a co-flowing air stream was made by adopting the flame surface model of infinite chemical reaction rate and unit Lewis number. The time dependent compressible Navier–Stokes equation was solved numerically with the equation for coupling function by using a finite difference method. The temperature-dependence of viscosity and diffusion coefficient were taken into account so as to study effects of increases of these coefficients on the transition. The numerical calculation was done for the case when methane is injected into a co-flowing air stream with variable injection Reynolds number up to 2500. When the Reynolds number was smaller than 1000 the flame, as well as the flow, remained laminar in the calculated domain. As the Reynolds number was increased above this value, a transition point appeared along the flame, downstream of which the flame and flow began to fluctuate. Two kinds of fluctuations were observed, a small scale fluctuation near the jet axis and a large scale fluctuation outside the flame surface, both of the same origin, due to the Kelvin–Helmholtz instability. The radial distributions of density and transport coefficients were found to play dominant roles in this instability, and hence in the transition mechanism. The decreased density in the flame accelerated the instability, while the increase in viscosity had a stabilizing effect. However, the most important effect was the increase in diffusion coefficient. The increase shifted the flame surface, where the large density decrease occurs, outside the shear layer of the jet and produced a thick viscous layer surrounding the jet which effectively suppressed the instability.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1781
Author(s):  
Weiyu Lu ◽  
Xin Fu ◽  
Jinchun Wang ◽  
Yuanchi Zou

Vibration wall control is an important active flow control technique studied by many researchers. Although current researches have shown that the control performance is greatly affected by the frequency and amplitude of the vibration wall, the mechanism hiding behind the phenomena is still not clear, due to the complex interaction between the vibration wall and flow separation. To reveal the control mechanism of vibration walls, we propose a simplified model to help us understand the interaction between the forced excitation (from the vibration wall) and self-excitation (from flow instability). The simplified model can explain vibration wall flow control behaviors obtained by numerical simulation, which show that the control performance will be optimized at a certain reduced vibration frequency or amplitude. Also, it is shown by the analysis of maximal Lyapunov exponents that the vibration wall is able to change the flow field from a disordered one into an ordered one. Consistent with these phenomena and bringing more physical insight, the simplified model implies that the tuned vibration frequency and amplitude will lock in the unsteady flow separation, promote momentum transfer from the main stream to the separation zone, and make the flow field more orderly and less chaotic, resulting in a reduction of flow loss.


Author(s):  
Longxin Zhang ◽  
Le Cai ◽  
Bao Liu ◽  
Jun Ding ◽  
Songtao Wang

As a promising active flow control method, boundary layer suction (BLS) can be used to enhance the aerodynamic performance of the highly-loaded compressor effectively, and due to this reason, extensive studies have been carried out on it. However, contrast to those abundant studies focusing on the flow control effects of BLS, little attention has been paid on the design method of the aspiration flow path. This work presents a 3-D steady numerical simulation on a highly-loaded aspirated compressor cascade. The aspiration slot is implemented at its best location based on the previous experimental studies and the aspiration flow rate is fix to 1.5% of the inlet massflow. The plenum configuration follows the blade shape and remains unchanged. One-side-aspiration manner is adopted to simplify the aspiration devices. Two critical geometry parameters, slot angle and slot width, are varied to study the effects of blade aspiration slot configuration on the cascade loss, radial distribution of the aspiration flow rate and inner flow structures within the aspiration flow path. Results show that the slot configuration does affect the cascade performance. In comparison with the throughflow performance, it is especially true once the flow loss caused by the aspiration flow path is also taken into account, and higher flow loss will be generated within the aspiration flow path if an inappropriate scheme is adopted. In the present investigation, apart from the cases with larger negative slot angle, a wider slot is more preferable to a narrower one, since it could enhance the aspiration capacity near the endwall regions and lower the dissipation loss within the aspiration flow path. In terms of the slot angle, a larger negative value, i.e., the slot direction more aligned with the incoming flow, is not beneficial to improve the throughflow performance, while concerning the flow loss yield by the aspiration flow path, a proper negative slot angle is always optimal.


Author(s):  
Marcel Staats ◽  
Wolfgang Nitsche

We present results of experiments on a periodically unsteady compressor stator flow of the type which would be expected in consequence of pulsed combustion. A Reynolds number of Re = 600000 was used for the investigations. The experiments were conducted on the two-dimensional low-speed compressor testing facility in Berlin. A choking device downstream the trailing edges induced a periodic non-steady outflow condition to each stator vane which simulated the impact of a pressure gaining combuster downstream from the last stator. The Strouhal number of the periodic disturbance was Sr = 0.03 w.r.t. the stator chord length. Due to the periodic non-steady outflow condition, the flow-field suffers from periodic flow separation phenomena, which were managed by means of active flow control. In our case, active control of the corner separation was applied using fluidic actuators based on the principle of fluidic amplification. The flow separation on the centre region of the stator blade was suppressed by means of a fluidic blade actuator leading to an overall time-averaged loss reduction of 11.5%, increasing the static pressure recovery by 6.8% while operating in the non-steady regime. Pressure measurements on the stator blade and the wake as well as PIV data proved the beneficial effect of the active flow control application to the flow field and the improvement of the compressor characteristics. The actuation efficiency was evaluated by two figures of merit introduced in this contribution.


Author(s):  
Finn Lückoff ◽  
Moritz Sieber ◽  
Christian Oliver Paschereit ◽  
Kilian Oberleithner

Abstract The reduction of polluting NOx emission remains a driving factor in the design process of swirl-stabilized combustion systems, to meet strict legislative restrictions. In reacting swirl flows, hydrodynamic coherent structures, such as periodic large-scale vortices in the shear layer, induce zones with increased heat release rate fluctuations in connection with temperature peaks, which lead to an increase of NOx emissions. Such large-scale vortices can be induced by the helical coherent structure known as precessing vortex core (PVC), which influences the flow and flame dynamics of reacting swirl flows under certain operating conditions. We developed an active flow control system, which allows for a targeted actuation of the PVC, to investigate its impact on important combustion properties. In this study, the direct active flow control is used to actuate a PVC of arbitrary frequency and amplitude, which facilitates a systematic study of the impact of the PVC on NOx emissions. In the course of the present work, a perfectly premixed flame, which slightly damps the PVC, is studied in detail. Since the PVC is slightly damped, it can be precisely excited by means of open-loop flow control. In connection with time-resolved OH*-chemiluminescence and stereoscopic PIV measurements, the flame and flow response to PVC actuation as well as the impact of the actuated PVC on flow and flame dynamics are characterized. It turns out that the PVC rolls up the inner shear layer, which results in an interaction of PVC-induced vortices and flame. This interaction considerably influences the measured level of NOx emissions, which grow with increasing PVC amplitude in a perfectly premixed flame. Nearly the same increase is to be seen for a partially premixed flame. This in contrast to previous studies, where the PVC is assumed to reduce the NOx emissions due to vortex-enhanced mixing.


Author(s):  
Junkyu Jung ◽  
Daren Elcock ◽  
Chih-Jung Kuo ◽  
Michael Amitay ◽  
Yoav Peles

A flow control method is presented that employ liquid and gas jets to enhance heat and mass transfer in micro domains. By introducing pressure disturbances, mixing can be significantly enhanced through the promotion of early transition to a turbulent flow. Since heat transfer mechanisms are closely linked to flow characteristics, the heat transfer coefficient can be significantly enhanced with rigorous mixing. The flow field of water around a low aspect ratio micro circular pillar of diameter 150 μm entrenched inside a 225 μm high by 1500 μm wide microchannel with active flow control was studied and its effect on mixing is discussed. A steady control jet emanating from a 25 μm slit on the pillar was introduced to induce favorable disturbances to the flow in order to modify the flow field, promote turbulence, and increase large-scale mixing. Micro particle image velocimetry (μPIV) was employed to quantify the flow field, the spanwise vorticity, and the turbulent kinetic energy (TKE) in the microchannel. Flow regimes (i.e., steady, transition from quasi-steady to unsteady, and unsteady flow) were elucidated. The turbulent kinetic energy was shown to significantly increase with the controlled jet, and therefore, significantly enhance mixing at the micro scale.


Author(s):  
Jun Liu ◽  
Hongrui Liu ◽  
Guang Liu ◽  
Qiang Du ◽  
Pei Wang ◽  
...  

After being studied for years, aggressive intermediate turbine duct is being attempted to be applied in turbine design to further improve the engine-performance. With such design, the shaft could be shortened effectively. However, under the influence of the more distorted coming-flow and stronger pressure-gradient in a real engine, the flow field would be more complicated definitely. Besides that, the upstream-rotor tip-leakage flow is a key loss-source by inducing separation. Flow-control strategies are necessary in this situation. In this paper, the flow field in an aggressive duct has been analyzed to declare the source of separation primarily. Then wide-chord blade design concept has been adopted as a control strategy firstly to realize the purpose of improving the areo-performance. After being verified, numerical method has been used in this study. Under the same aero-condition, the prototype and the modified turbine are analyzed. With this novel flow-control strategy, separation has been improved, even diminished. However, the flow structures within the blade passage are altered correspondingly. An instrumental conclusion is that the pressure loss could be decreased successfully by designing the wide-chord blade specially.