Stability Improvement of a Turbocharger Centrifugal Compressor by a Nonaxisymmetric Vaned Diffuser

2018 ◽  
Vol 140 (4) ◽  
Author(s):  
Xinqian Zheng ◽  
Zhenzhong Sun ◽  
Tomoki Kawakubo ◽  
Hideaki Tamaki

The nonuniformity of the flow field induced by a nonaxisymmetric volute significantly degrades the stability of a turbocharger centrifugal compressor. In this paper, a nonaxisymmetric vaned diffuser is investigated as a nonaxisymmetric flow control method using both three-dimensional computational fluid dynamics (CFD) and experiment. The numerical study first focuses on the relationship between the flow field and the static pressure distortion, and the steady CFD results indicate that the positive static pressure gradient in the rotating direction facilitates flow separation in the vaned diffuser and induces a nonuniform flow field. A nonaxisymmetric flow control method with variable stagger and solidity of the vaned diffuser is developed to suppress the flow separation, and the guideline of the method suggests narrowing flow passages where the flow separates or closing diffuser vanes upstream of flow separations. Steady CFD also presents the flow field of the investigated turbocharger centrifugal compressor with volute, and flow separation is found in the flow passages near the volute tongue. Under the guidance of the nonaxisymmetric flow control method, several nonaxisymmetric vaned diffusers are designed to make the flow field uniform, which are believed to be beneficial for compressor stability. Finally, an experiment is carried out to validate the positive effects of the nonaxisymmetric vaned diffuser for stability improvement. The test data show that Non-AxisVD (with a nonaxisymmetric vaned diffuser) extends the stable flow range (SFR) of the compressor by 26% compared with the AxisVD (with an axisymmetric vaned diffuser), at the cost of acceptable decreases in the maximum total pressure ratio and peak efficiency.

2012 ◽  
Vol 135 (2) ◽  
Author(s):  
Mingyang Yang ◽  
Xinqian Zheng ◽  
Yangjun Zhang ◽  
Takahiro Bamba ◽  
Hideaki Tamaki ◽  
...  

This is Part I of a two-part paper documenting the development of a novel asymmetric flow control method to improve the stability of a high-pressure-ratio turbocharger centrifugal compressor. Part I focuses on the nonaxisymmetrical flow in a centrifugal compressor induced by the nonaxisymmetrical geometry of the volute while Part II describes the development of an asymmetric flow control method to avoid the stall on the basis of the characteristic of nonaxisymmetrical flow. To understand the asymmetries, experimental measurements and corresponding numerical simulation were carried out. The static pressure was measured by probes at different circumferential and stream-wise positions to gain insights about the asymmetries. The experimental results show that there is an evident nonaxisymmetrical flow pattern throughout the compressor due to the asymmetric geometry of the overhung volute. The static pressure field in the diffuser is distorted at approximately 90 deg in the rotational direction of the volute tongue throughout the diffuser. The magnitude of this distortion slightly varies with the rotational speed. The magnitude of the static pressure distortion in the impeller is a function of the rotational speed. There is a significant phase shift between the static pressure distributions at the leading edge of the splitter blades and the impeller outlet. The numerical steady state simulation neglects the aforementioned unsteady effects found in the experiments and cannot predict the phase shift, however, a detailed asymmetric flow field structure is obviously obtained.


Author(s):  
Mingyang Yang ◽  
Xinqian Zheng ◽  
Yangjun Zhang ◽  
Takahiro Bamba ◽  
Hideaki Tamaki ◽  
...  

This is the Part I of a two-part paper documenting the development of a novel asymmetric flow control method to improve the stability of a high-pressure-ratio turbocharger centrifugal compressor. Part I focuses on the non-axisymmetric flow in a centrifugal compressor induced by the non-axisymmetric geometry of the volute while Part II describes the development of asymmetric flow control method to avoid the stall on the basis of the characteristic of non-axisymmetric flow. To understand the asymmetries, experimental measurements and corresponding numerical simulation were carried out. The static pressure was measured by probes at different circumferential and stream-wise positions to gain insights about the asymmetries. The experiment results show that there is an evident non-axisymmetric flow pattern throughout the compressor due to the asymmetric geometry of overhung volute. The static pressure field in the diffuser is distorted at approximately 90° in rotational direction of the volute tongue throughout the diffuser. The magnitude of this distortion varies slightly with the rotational speeds. The magnitude of the static pressure distortion in the impeller is a function of the rotational speed. There is a significant phase shift between the static pressure distributions at the leading edge of the splitter blades and the impeller outlet. The numerical steady state simulation neglects the mentioned unsteady effects found in the experiments and can not predict the phase shift, but a detailed asymmetric flow field structure are obviously obtained.


2014 ◽  
Vol 663 ◽  
pp. 347-353
Author(s):  
Layth H. Jawad ◽  
Shahrir Abdullah ◽  
Zulkifli R. ◽  
Wan Mohd Faizal Wan Mahmood

A numerical study that was made in a three-dimensional flow, carried out in a modified centrifugal compressor, having vaned diffuser stage, used as an automotive turbo charger. In order to study the influence of vaned diffuser meridional outlet section with a different width ratio of the modified centrifugal compressor. Moreover, the performance of the centrifugal compressor was dependent on the proper matching between the compressor impeller along the vaned diffuser. The aerodynamic characteristics were compared under different meridional width ratio. In addition, the velocity vectors in diffuser flow passages, and the secondary flow in cross-section near the outlet of diffuser were analysed in detail under different meridional width ratio. Another aim of this research was to study and simulate the effect of vaned diffuser on the performance of a centrifugal compressor. The simulation was undertaken using commercial software so-called ANSYS CFX, to predict numerically the performance charachteristics. The results were generated from CFD and were analysed for better understanding of the fluid flow through centrifugal compressor stage and as a result of the minimum width ratio the flow in diffuser passage tends to be uniformity. Moreover, the backflow and vortex near the pressure surface disappear, and the vortex and detachment near the suction surface decrease. Conclusively, it was observed that the efficiency was increased and both the total pressure ratio and static pressure for minimum width ratio are increased.


Author(s):  
T. Ch. Siva Reddy ◽  
G. V. Ramana Murty ◽  
Prasad Mukkavilli ◽  
D. N. Reddy

Numerical simulation of impeller and low solidity vaned diffuser (LSD) of a centrifugal compressor stage is performed individually using CFX- BladeGen and BladeGenPlus codes. The tip mach number for the chosen study was 0.35. The same configuration was used for experimental investigation for a comparative study. The LSD vane is formed using standard NACA profile with marginal modification at trailing edge. The performance parameters obtained form numerical studies at the exit of impeller and the diffuser have been compared with the corresponding experimental data. These parameters are pressure ratio, polytropic efficiency and flow angle at the impeller exit where as the parameters those have been compared at the exit of diffuser are the static pressure recovery coefficient and the exit flow angle. In addition, the numerical prediction of the blade loading in terms of blade surface pressure distribution on LSD vane has been compared with the corresponding experimental results. Static pressure recovery coefficient and flow angle at diffuser exit is seen to match closely at higher flows. The difference at lower flows could be due to the effect of interaction between impeller and diffuser combinations, as the numerical analysis was done separately for impeller and diffuser and the effect of impeller diffuser interaction was not considered.


Author(s):  
Mingyang Yang ◽  
Ricardo Martinez-Botas ◽  
Yangjun Zhang

The operating range of a centrifugal compressor, determined by surge and choke flow rate, is a key issue for turbocharging since a vehicle internal combustion engine (ICE) is usually operated across a wide range. In this paper a new flow control method is developed and validated numerically, in which an array of circumferentially distributed holes is designed in the inner wall of the inlet duct of a high pressure ratio centrifugal compressor of a turbocharger. Firstly the numerical method is validated by experimental results of the original turbocharging centrifugal compressor with a pressure ratio of 4. Next the validated method is used to investigate the new flow control method and its effect on the compressor’s performance. Results show that the method can enhance the compressor stability and widen the operating range effectively at all investigated speeds. At meantime, the choke flow reduces slightly. The flow details in the compressor are further analysed according to the CFD results. It is found that the flow near the blade tip at inlet is pre-swirled by the method as the conventional IGV does while the flow in the middle span or near the hub remains in an axial direction. As a result, the stability of the compressor is enhanced by the pre-swirl effect at the tip while minimally sacrificing the choke flow rate, thus the map is extended effectively by the flow control method.


Author(s):  
Mahdi Nili-Ahmadabadi ◽  
Ali Hajilouy-Benisi ◽  
Mohammad Durali ◽  
Sayyed Mostafa Motavalli

In this research, the centrifugal compressor of a turbocharger is investigated experimentally and numerically. Performance characteristics of the compressor were obtained experimentally by measurements of rotor speed and flow parameters at the inlet and outlet of the compressor. Three dimensional flow field in the impeller and diffuser was analyzed numerically using a full Navier-Stokes program with SST turbulence model. The performance characteristics of the compressor were obtained numerically, which were then compared with the experimental results. The comparison shows good agreement. Furthermore, the effect of area ratio and tip clearance on the performance parameters and flow field was studied numerically. The impeller area ratio was changed by cutting the impeller exit axial width from an initial value of 4.1 mm to a final value of 5.1 mm, resulting in an area ratio from 0.792 to 0.965. For the rotor with exit axial width of 4.6 mm, performance was investigated for tip clearance of 0.0, 0.5 and 1.0 mm. Results of this simulation at design point showed that the compressor pressure ratio peaked at an area ratio of 0.792 while the efficiency peaked at a higher value of area ratio of 0.878. Also the increment of the tip clearance from 0 to 1 mm resulted in 20 percent efficiency decrease.


Author(s):  
Xinqian Zheng ◽  
Yangjun Zhang ◽  
Mingyang Yang ◽  
Takahiro Bamba ◽  
Hideaki Tamaki

This is the Part II of a two-part paper involving the development of asymmetric flow control method to widen the operating range of a turbocharger centrifugal compressor with high-pressure-ratio. Non-axisymmetric Self Recirculation Casing Treatment (SRCT) as an instance of asymmetric flow control method is presented. Experimental and numerical methods were used to investigate the impact of non-axisymmetric SRCT on surge point of the centrifugal compressor. Firstly, the influence of the geometry of a symmetric SRCT on the compressor performance was studied by means of numerical simulation. The key parameter of the SRCT was found to be the distance from the main blade leading edge to the rear groove (Sr). Next, several arrangements of a non-axisymmetric SRCT were designed, based on flow analysis presented in Part I. Then, a series of experiments was carried out to analyze the influence of non-axisymmetric SRCT on the compressor performance. Results show that the non-axisymmetry SRCT has certain influence on performance and has a larger potential for stability improvement than the traditional symmetric SRCT. For the investigated SRCT, the surge flow rate of the compressor with the non-axisymmetric SRCT is about 10% lower than that of the compressor with symmetric SRCT. The largest surge margin (smallest surge flow rate) can be obtained when the phase of the largest Sr is coincident with the phase of the minimum static pressure in the vicinity of the leading edge of the splitter blades.


2008 ◽  
Vol 130 (1) ◽  
Author(s):  
Michele Marconcini ◽  
Filippo Rubechini ◽  
Andrea Arnone ◽  
Seiichi Ibaraki

A three-dimensional Navier-Stokes solver is used to investigate the flow field of a high-pressure ratio centrifugal compressor for turbocharger applications. Such a compressor consists of a double-splitter impeller followed by a vaned diffuser. The inlet flow to the open shrouded impeller is transonic, thus giving rise to interactions between shock waves and boundary layers and between shock waves and tip leakage vortices. These interactions generate complex flow structures which are convected and distorted through the impeller blades. Detailed laser Doppler velocimetry flow measurements are available at various cross sections inside the impeller blades highlighting the presence of low-velocity flow regions near the shroud. Particular attention is focused on understanding the physical mechanisms which govern the flow phenomena in the near shroud region. To this end numerical investigations are performed using different tip clearance modelizations and various turbulence models, and their impact on the computed flow field is discussed.


Author(s):  
Teemu Turunen-Saaresti ◽  
Aki-Pekka Gro¨nman ◽  
Ahti Jaatinen

A centrifugal compressor is often equipped with a vaneless diffuser because the operation range of a vaneless diffuser is wider than the operation range of vaned diffuser, and the geometry of the vaneless diffuser is simple and inexpensive. The flow field after the centrifugal compressor rotor is highly complicated and the velocity is high. A moderate amount of this velocity should be recovered to the static pressure. It is important to study the flow field in the vaneless diffuser in order to achieve guidelines for design and an optimal performance. In this article, the experimental study of the pinch in the vaneless diffuser is conducted. Five different diffuser heights were used, b/b2 = 1, b/b2 = 0.903, b/b2 = 0.854, b/b2 = 0.806 and b/b2 = 0.903 (shroud). In three of the cases, the pinch was made to both walls of the diffuser, hub and shroud, and in one case, the pinch was made to the shroud wall. The total and the static pressure, the total temperature and the flow angle were measured at the diffuser inlet and outlet by using a cobra-probe, kiel-probes and flush-mounted pressure taps. In addition, the static pressure in the diffuser was measured at three different radius ratios. The overall performance, the mass flow, the pressure ratio and the isentropic efficiency of the compressor stage were also monitored. Detailed flow field measurements were carried out at the design rotational speed and at the three different mass flows (close to the surge, design and close to the choke). The isentropic efficiency and the pressure ratio of the compressor stage was increased with the pinched diffuser. The efficiency of the rotor and the diffuser was increased, whereas the efficiency of the volute/exit cone was decreased. The pinch made to the shroud wall was the most effective. The pinch made the flow angle more radial and increased the velocity at the shroud where the secondary flow (passage wake) from the rotor is present.


2012 ◽  
Vol 135 (2) ◽  
Author(s):  
Xinqian Zheng ◽  
Yangjun Zhang ◽  
Mingyang Yang ◽  
Takahiro Bamba ◽  
Hideaki Tamaki

This is part II of a two-part paper involving the development of an asymmetrical flow control method to widen the operating range of a turbocharger centrifugal compressor with high-pressure ratio. A nonaxisymmetrical self-recirculation casing treatment (SRCT) as an instance of asymmetrical flow control method is presented. Experimental and numerical methods were used to investigate the impact of nonaxisymmetrical SRCT on the surge point of the centrifugal compressor. First, the influence of the geometry of a symmetric SRCT on the compressor performance was studied by means of numerical simulation. The key parameter of the SRCT was found to be the distance from the main blade leading edge to the rear groove (Sr). Next, several arrangements of a nonaxisymmetrical SRCT were designed, based on flow analysis presented in part I. Then, a series of experiments were carried out to analyze the influence of nonaxisymmetrical SRCT on the compressor performance. Results show that the nonaxisymmetrical SRCT has a certain influence on the performance and has a larger potential for stability improvement than the traditional symmetric SRCT. For the investigated SRCT, the surge flow rate of the compressor with the nonaxisymmetrical SRCTs is about 10% lower than that of the compressor with symmetric SRCT. The largest surge margin (smallest surge flow rate) can be obtained when the phase of the largest Sr is coincident with the phase of the minimum static pressure in the vicinity of the leading edge of the splitter blades.


Sign in / Sign up

Export Citation Format

Share Document