Aerodynamic Effects in a Transonic Compressor With Nonaxisymmetric Tip Clearance

Author(s):  
Maximilian Jüngst ◽  
Samuel Liedtke ◽  
Heinz Peter Schiffer ◽  
Bernd Becker

Future axial compressor designs tend to be built with larger relative tip gaps and eccentricity, since the core engines are reduced in size. Our knowledge of the aerodynamic effects due to eccentric tip gaps is largely based on low-speed work. The aim of this study is to widen current knowledge by using the 1.5 stage Darmstadt Transonic Compressor, which is representative of the front stage of a high pressure compressor. Efficiency, peak pressure rise and stability margin of the compressor are reduced linearly at design speed when the tip clearance is increased from 0.9% to 2.5% tip chord length. This holds true for configurations with eccentric rotor tip gap, if their circumferentially averaged gaps are considered. For a compressor with 96% eccentricity and 1.7% average tip clearance, corrected mass flow at rotor exit varies locally with up to ±20% and ±10% at stator exit, which can result in inlet distortions for subsequent stages in a multi-stage configuration. Also, the redistribution of flow massively influences stall inception during throttling at constant speed. Propagating disturbances are damped in sectors with higher inlet mass flow and lower incidence. Thus, overall operation remains stable, even though some sectors are highly disturbed. Consequently, the maximum clearance of an eccentric stage is not limiting the stable operation of the whole stage.

Author(s):  
Joshua D. Cameron ◽  
Matthew A. Bennington ◽  
Mark H. Ross ◽  
Scott C. Morris ◽  
Thomas C. Corke

Effects of rotor centerline offset and whirl on the pre-stall and stall inception behavior of a high-speed tip-critical axial compressor were investigated. The observations were made using a circumferential array of unsteady pressure transducers. The maximum amount of rotor offset and whirl used in this investigation was 26% and 13% of the design axisymmetric tip clearance respectively. Measurements were conducted using transient throttle movements which quickly decreased the mass flow in the compressor until the onset of rotating stall. A second set of measurements used quasi-transient throttling starting from a mass flow about 0.5% larger than the stalling mass flow. These data were analyzed with the traveling wave energy method, visual inspection of the filtered pressure traces, and a two-point spatial correlation technique. For the uniform tip clearance case rotating stall occurred while the slope of the pressure rise characteristic was negative. As expected, the flow breakdown exhibited “spike” inception with no observable rotating disturbances in the pre-stall time period. The introduction of small levels of steady and unsteady tip clearance asymmetry did not significantly alter the time average performance of the stage; circumferential variations in pressure rise and flow coefficient were minimal and the stalling flow coefficient remained unchanged. However, significant short length-scale rotating disturbances were observed in both of these cases prior to stall inception. As in the symmetric tip clearance case, short length-scale disturbances initiated rotating stall in the non-uniform tip clearance experiments. The location of the generation of the incipient stall cells with respect to the non-uniform tip clearance was strongly effected by the rotor offset/whirl.


Author(s):  
Jiaguo Hu ◽  
Tianyu Pan ◽  
Wenqian Wu ◽  
Qiushi Li ◽  
Yifang Gong

The instability has been the largest barrier of the high performance axial compressor in the past decades. Stall inception, which determines the route and the characteristics of instability evolution, has been extensively focused on. A new stall inception, “partial surge”, is discovered in the recent experiments. In this paper full-annulus transient simulations are performed to study the origin of partial surge initiated inception and explain the aerodynamic mechanism. The simulations show that the stall inception firstly occurs at the stator hub region, and then transfers to the rotor tip region. The compressor finally stalled by the tip region rotating stall. The stall evolution is in accord with the experiments. The stall evolution can be divided into three phases. In the first phase, the stator corner separation gradually merged with the adjacent passages, producing an annulus stall cell at the stator hub region. In the second phase, the total pressure rise of hub region emerges rapid decline due to the fast expansion of the annulus stall cell, but the tip region maintains its pressure rise. In the third phase, a new rotating stall cell appears at the rotor tip region, leading to the onset of fast drop of the tip region pressure rise. The stall cells transfer from hub region to the tip region is caused by two factors, the blockage of the hub region which transfers more load to the tip region, and the separation fluid fluctuations in stator domain which increase the circumferential non-uniformity in the rotor domain. High load and non-uniformity at the rotor tip region induce the final rotating stall.


Author(s):  
Yiming Zhong ◽  
WuLi Chu ◽  
HaoGuang Zhang

Abstract Compared to the traditional casing treatment, the self-recirculating casing treatment (SCT) can improve or not decrease the compressor efficiency while achieving the stall margin improvement. For the bleed port, the main design indicator is to reduce the flow loss caused by suction, while providing sufficient jet flow and jet pressure to the injector. In order to gain a better study of the bleed port stabilization mechanisms, the bleed configuration was parameterized with the bleed port inlet width and the bleed port axial position. Five kinds of recirculating casing treatments were applied to a 1.5-stage transonic axial compressor with the method of three-dimensional unsteady numerical simulation. Fifteen identical self-recirculating devices are uniformly mounted around the annulus. The numerical results show that the SCT can improve compressor total pressure ratio and stability, shift the stall margin towards lower mass flows. Furthermore, it has no impact on compressor efficiency. The optimal case presents that stability margin is improved by 6.7% employing 3.1% of the annulus mass flow. Expanding bleed port inlet width to an intermediate level can further enhance compressor stability, but excessive bleed port inlet width will reduce the stabilization effect. The optimal bleed port position is located in the blocked area of the low energy group at the top of the rotor. In the case of solid casing, stall inception was the tip blockage, which was mainly triggered by the interaction of the tip leakage vortex and passage shock. From radial distribution, the casing treatment predominantly affects the above 70% span. The reduction of tip reflux region by suction effect is the main reason for the extension of stable operation range. The SCT also has an obvious stability improvement in tip blockage stall, while delaying the occurrence of compressor stall.


Author(s):  
Garth V. Hobson ◽  
Anthony J. Gannon ◽  
Scott Drayton

A new design procedure was developed that uses commercial-off-the-shelf software (MATLAB, SolidWorks, and ANSYS-CFX) for the geometric rendering and analysis of a transonic axial compressor rotor with splitter blades. Predictive numerical simulations were conducted and experimental data were collected in a Transonic Compressor Rig. This study advanced the understanding of splitter blade geometry, placement, and performance benefits. In particular, it was determined that moving the splitter blade forward in the passage between the main blades, which was a departure from the trends demonstrated in the few available previous transonic axial compressor splitter blade studies, increased the mass flow range with no loss in overall performance. With a large 0.91 mm (0.036 in) tip clearance, to preserve the integrity of the rotor, the experimentally measured peak total-to-total pressure ratio was 1.69 and the peak total-to-total isentropic efficiency was 72 percent at 100 percent design speed. Additionally, a higher than predicted 7.5 percent mass flow rate range was experimentally measured, which would make for easier engine control if this concept were to be included in an actual gas turbine engine.


Author(s):  
Chunill Hah ◽  
Jo¨rg Bergner ◽  
Heinz-Peter Schiffer

The current paper reports on investigations aimed at advancing the understanding of the flow mechanism that leads to the onset of short-length scale rotating stall in a transonic axial compressor. Experimental data show large oscillation of the tip clearance vortex as the rotor operates near the stall condition. Inception of spike-type rotating stall is also measured in the current transonic compressor with high response pressure transducers. Computational studies of a single passage and the full annulus were carried out to identify flow mechanisms behind the spike-type stall inception in the current transonic compressor rotor. Steady and unsteady single passage flow simulations were performed, first to get insight into the interaction between the tip clearance vortex and the passage shock. The conventional Reynolds-averaged Navier-Stokes method with a standard turbulence closure scheme does not accurately reproduce tip clearance vortex oscillation and the measured unsteady pressure field. Consequently, a Large Eddy Simulation (LES) was carried out to capture more relevant physics in the computational simulation of the rotating stall inception. The unsteady random behavior of the tip clearance vortex and it’s interaction with the passage shock seem to be critical ingredients in the development of spike-type rotating stall in a transonic compressor. The Large Eddy Simulation was further extended to the full annulus to identify flow mechanisms behind the measured spike-type rotating stall inception. The current study shows that the spike-type rotating stall develops after the passage shock is fully detached from the blade passages. Interaction between the tip clearance vortex and the passage shock creates a low momentum area near the pressure side of the blade. As the mass flow rate decreases, this low momentum area moves further upstream and reversed tip clearance flow is initiated at the trailing edge plane. Eventually, the low momentum area near the pressure side reaches the leading edge and forward spillage of the tip clearance flow occurs. The flows in the affected blade passage or passages then stall. As the stalled blade passages are formed behind the passage shock, the stalled area rotates counter to the blade rotation just like the classical Emmon’s type rotating stall. Both the measurements and the computations show that the rotating stall cell covers one to two blade passage lengths and rotates at roughly 50% of the rotor speed.


2008 ◽  
Vol 130 (4) ◽  
Author(s):  
Jen-Ping Chen ◽  
Michael D. Hathaway ◽  
Gregory P. Herrick

Computational fluid dynamics calculations using high-performance parallel computing were conducted to simulate the prestall flow of a transonic compressor stage, NASA compressor Stage 35. The simulations were run with a full-annulus grid that models the 3D, viscous, unsteady blade row interaction without the need for an artificial inlet distortion to induce stall. The simulation demonstrates the development of the rotating stall from the growth of instabilities. Pressure rise performance and pressure traces are compared with published experimental data before the study of flow evolution prior to the rotating stall. Spatial fast Fourier transform analysis of the flow indicates a rotating long-length disturbance of one rotor circumference, which is followed by a spike-type breakdown. The analysis also links the long-length wave disturbance with the initiation of the spike inception. The spike instabilities occur when the trajectory of the tip clearance flow becomes perpendicular to the axial direction. When approaching stall, the passage shock changes from a single oblique shock to a dual shock, which distorts the perpendicular trajectory of the tip clearance vortex but shows no evidence of flow separation that may contribute to stall.


Author(s):  
Scott C. Morris ◽  
Joshua D. Cameron ◽  
Matthew A. Bennington ◽  
G. Scott McNulty ◽  
Aspi Wadia

The performance, efficiency, and stall inception of an axial compressor was investigated experimentally with small levels of rotor centerline offset. The measurements were acquired using a high-speed, single-stage compressor. The rotor was levitated magnetically during operation which allowed precise positioning of the rotor centerline within the circular casing. The offset magnitude used in this study was 0.23% of the rotor tip chord, equivalent to approximately 24% of the nominal gap value. The resulting asymmetry in the tip gap resulted in circumferential and radial variations in the measured stagnation pressure and stagnation temperature downstream of the stage. However, the spatially averaged performance of the compressor was not measurably different from that obtained with a concentric rotor. An array of unsteady (Kulite) pressure transducers was used to investigate the flow field during stall inception. These measurements were recorded during transient throttle movements which quickly decreased the mass flow in the compressor until the onset of rotating stall. A second set of measurements was acquired during quasi-transient throttling starting from a mass flow about 1% larger than the stalling mass flow. In both the symmetric and offset cases the flow breakdown was consistent with spike type inception. The measurements with offset indicated that the asymmetries in the local compressor flow field produced significant changes in the number of short-length scale rotating disturbances observed during throttling to stall. These disturbances appeared in the region of the annulus where the local flow coefficient was lowest and usually decayed upon rotating to the higher flow region. In this way, the addition of very small amounts of rotor offset tended to fix the disturbance generation location in the stationary reference frame. This was in contrast to the symmetric tip clearance case where the location of spike generation appeared stochastic.


Author(s):  
Jen-Ping Chen ◽  
Michael D. Hathaway ◽  
Gregory P. Herrick

CFD calculations using high-performance parallel computing were conducted to simulate the pre-stall flow of a transonic compressor stage, NASA compressor Stage 35. The simulations were run with a full-annulus grid that models the 3-D, viscous, unsteady blade row interaction without the need for an artificial inlet distortion to induce stall. The simulation demonstrates the development of the rotating stall from the growth of instabilities. Pressure-rise performance and pressure traces are compared with published experimental data before launching a detailed study of the flow evolution prior to the rotating stall. Spatial FFT analysis of the flow indicates a rotating long-length disturbance of one rotor circumference, which is followed by a spike-type breakdown. The analysis also links the long-length wave disturbance with the initiation of the spike inception. The spike instabilities occur when the trajectory of the tip clearance flow becomes vertical to the axial direction. When approaching to stall, the passage shock changes from a single oblique shock to a dual-shock, which distorts the vertical trajectory of the tip clearance vortex but shows no evidence to cause flow separation that may contribute to stall.


Author(s):  
Byeung Jun Lim ◽  
Tae Choon Park ◽  
Young Seok Kang

In this study, characteristics of stall inception in a single-stage transonic axial compressor with circumferential grooves casing treatment were investigated experimentally. Additionally, the characteristic of increasing irregularity in the pressure inside circumferential grooves as the compressor approaches the stall limit was applied to the stall warning method. Spike-type rotating stall was observed in the single-stage transonic axial compressor with smooth casing. When circumferential grooves were applied, the stall inception was suppressed and the operating point of the compressor moved to lower flow rate than the stall limit. A spike-like disturbance was developed into a rotating stall cell and then the Helmholtz perturbation was overlapped on it at N = 80%. At N = 70 %, the Helmholtz perturbation was observed first and the amplitude of the wave gradually increased as mass flow rate decreased. At N = 60%, spike type stall inceptions were observed intermittently and then developed into continuous rotating stall at lower mass flow rate. Pressure measured at the bottom of circumferential grooves showed that the level of irregularity of pressure increased as flow rate decreased. Based on the characteristic of increasing irregularity of the pressure signals inside the circumferential grooves as stall approaches, an autocorrelation technique was applied to the stall warning. This technique could be used to provide warning against stall and estimate real-time stall margins in compressors with casing treatments.


2003 ◽  
Vol 125 (3) ◽  
pp. 405-415
Author(s):  
Ammar A. Al-Nahwi ◽  
James D. Paduano ◽  
Samir A. Nayfeh

This paper presents a first principles-based model of the fluid-induced forces acting on the rotor of an axial compressor. These forces are primarily associated with the presence of a nonuniform flow field around the rotor, such as that produced by a rotor tip clearance asymmetry. Simple, analytical expressions for the forces as functions of basic flow field quantities are obtained. These expressions allow an intuitive understanding of the nature of the forces and—when combined with a rudimentary model of an axial compressor flow field (the Moore-Greitzer model)—enable computation of the forces as a function of compressor geometry, torque and pressure-rise characteristics, and operating point. The forces predicted by the model are also compared to recently published measurements and more complex analytical models, and are found to be in reasonable agreement. The model elucidates that the fluid-induced forces comprise three main contributions: fluid turning in the rotor blades, pressure distribution around the rotor, and unsteady momentum storage within the rotor. The model also confirms recent efforts in that the orientation of fluid-induced forces is locked to the flow nonuniformity, not to tip clearance asymmetry as is traditionally assumed. The turning and pressure force contributions are shown to be of comparable magnitudes—and therefore of equal importance—for operating points between the design point and the peak of the compressor characteristic. Within this operating range, both “forward” and “backward” rotor whirl tendencies are shown to be possible. This work extends recent efforts by developing a more complete, yet compact, description of fluid-induced forces in that it accounts for all relevant force contributions, both tangential and radial, that may influence the dynamics of the rotor. Hence it constitutes an essential element of a consistent treatment of rotordynamic stability under the action of fluid-induced forces, which is the subject of Part II of this paper.


Sign in / Sign up

Export Citation Format

Share Document