Development of Safety Assessment Code for Decommissioning of Nuclear Facilities (DecDose)

Author(s):  
Taro Shimada ◽  
Soichiro Ohshima ◽  
Takenori Sukegawa

A safety assessment code, DecDose, for decommissioning of nuclear facilities has been developed, based on the experiences of the decommissioning project of Japan Power Demonstration Reactor (JPDR) at Japan Atomic Energy Research Institute (now Japan Atomic Energy Agency). DecDose evaluates the annual exposure dose of the public and workers according to the progress of decommissioning of the plant, and also evaluates the public dose at accidental situations including fire and explosion. The public dose at normal situations during decommissioning is evaluated from the amount of radionuclides discharged from the plant to the atmosphere and the ocean. The amounts of radionuclides discharged depend on which and how activated and/or contaminated components and structures are dismantled. The amount is predicted by using the radioactive inventory given by the plant. The filtration efficiency of the ventilation system and decontamination factors of the liquid waste treatment system of the plant are also considered. Both of the internal dose caused by inhalation and ingestion of agricultural crops and seafood, and the external dose by radioactive aerosols airborne and radioactive deposition at soil surfaces are calculated for all of possible pathways. Also included in the external dose are direct radiation and skyshine radiation from waste containers which are packed and temporarily stored in the in-site building. For external dose of workers, the radiation dose rate from dismantling contaminated components and structures is calculated using the dose rate library which was previously evaluated by a point kernel shielding code. In this condition, radiation sources are regarded to be consisted of two parts; one is a dismantling object of interest, and the other is the sum of surrounding objects. Difference in job type or position is taken into account; workers for cutting are situated closer to a dismantling component, other workers help them at some distance, and the supervisor watches their activities from away. For worker’s internal dose, the radionuclide concentrations in air for individual radionuclides are calculated from a dismantling condition, e.g. cutting speed, cutting length of the dismantling component and exhaust velocity. A calculation model for working time on dismantling was developed using more segmented WBS (work breakdown structure). DecDose was partially verified by comparison with measured the external dose of workers during JPDR Decommissioning Project. The DecDose is expected to contribute to utilities in formulating rational dismantling plans and to the safety authority in estimating conservativeness in safety assessment of licensing application or risk-based regulatory criteria.

2020 ◽  
Author(s):  
S. Economides ◽  
C.J. Hourdakis ◽  
C. Pafilis ◽  
G. Simantirakis ◽  
P. Tritakis ◽  
...  

This paper concerns an analysis regarding the performance of X-ray equipment as well as the radiological safety in veterinary facilities. Data were collected from 380 X-ray veterinary facilities countrywide during the on-site regulatory inspections carried out by the Greek Atomic Energy Commission. The analysis of the results shows that the majority of the veterinary radiographic systems perform within the acceptable limits; moreover, the design and shielding of X-ray rooms as well as the applied procedures ensure a high level of radiological safety for the practitioners, operators and the members of the public. An issue that requires specific attention in the optimization process for the proper implementation of veterinary radiology practices in terms of radiological safety is the continuous training of the personnel. The above findings and the regulatory experience gained were valuable decision-making elements regarding the type of the regulatory control of veterinary radiology practices in the new radiation protection framework.


2019 ◽  
Vol 54 (4) ◽  
pp. 241-246 ◽  
Author(s):  
J.F. Bottollier-Depois ◽  
E. Allain ◽  
G. Baumont ◽  
N. Berthelot ◽  
G. Darley ◽  
...  

After the Fukushima accident, initiatives emerged offering the public the possibility to realise measurements of the radioactivity in the environment with various devices and to share data and experiences through collaborative tools. The objective of the OpenRadiation project is to offer the public the opportunity to perform measurements of the radioactivity using connected dosimeters on smartphones. The challenge is to operate such a system on a sustainable basis in normal situations and in order to be useful in an emergency situation. In normal situations, this project is based on a collaborative approach including pedagogical activities. In case of emergency situation, data from the field will be available in “real time” providing an opportunity for the emergency management and the communication with the public. The practical objectives are to develop i) a website centralising measurements using various dosimeters, providing dose rate maps with raw and filtered data and offering dedicated areas for specific projects and exchanges about data and ii) a dosimetric app using a connected dosimeter. This project is conducted within a partnership between organisms’ representative of the scientific community and associations to create links with the public.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Ali Abid Abojassim Al-Hamidawi

This paper presents the measurements of thoron and the progeny in fifteen buildings in Kufa Technical Institute, Iraq, from June 2015 to April 2015 using RAD-7 detectors. Also, annual effective dose rate was calculated in all buildings under study. The thoron concentration varies from05.35±0.58 Bq/m3to53.50±1.82 Bq/m3with an average18.39±4.18 Bq/m3. The concentration of thoron daughters was found to vary from 0.14 mWL to 1.44 mWL with an average0.53±0.11 mWL. The annual effective doses due to thoron mainly vary from 0.042 mSv/y to 0.81 mSv/y with an average0.20±0.06 mSv/y. The preliminary results in this study indicate that they may be suitable for evaluating the indoor220Rn and its progeny concentrations whenever the public exposure to220Rn and its progeny is taken into account. During this survey, the continuous difficulty in measuring thoron was also pointed out, due to its short half-life and faults in the measuring system.


2011 ◽  
Vol 147 (1-2) ◽  
pp. 264-266 ◽  
Author(s):  
N. Ahmadi Jeshvaghane ◽  
R. Paydar ◽  
B. Fasaei ◽  
A. Pakneyat ◽  
A. Karamloo ◽  
...  

1998 ◽  
Vol 44 ◽  
pp. 267-278
Author(s):  
Lord Selborne

In the course of a long and highly distinguished life, Lord Sherfield served in the Foreign Office, becoming Ambassador in Washington, was Joint Permanent Secretary of the Treasury, Chairman of the United Kingdom Atomic Energy Authority, Chancellor of the University of Reading, and held many other posts in the public and private sectors. In 1945, when Minister at the British Embassy in Washington, he took responsibility for advising on policy issues related to the nuclear weapons programme. Thereafter he was to remain an enthusiastic and most effective contributor to the advancement of science and technology.