Effect of Inlet Fluid Temperature on the Buoyancy Induced Flow in Circular Tube Inserted With Twisted Strip

Author(s):  
S. B. Thombre ◽  
S. V. Prayagi ◽  
N. V. Deshpande

The present work deals with experimental studies on heat transfer characteristic for buoyancy induced flow through inclined tubes inserted with twisted strips. The parameters varied during the experimetation are; tube inclination, heat supply twist pitch and fluid inlet temperature. It was found that the percentage enhancement in heat transfer coefficient decreases with increase in pitch and tube inclination. The flow rate is found to decrease with decrease in the pitch and increase in the tube inclination. It was also observed that the heat transfer coefficient and flow rate decreases with the increase in the inlet fluid temperature. This may be due to reduction in Rayleigh number caused because of higher heat loss at the tube surface.

2021 ◽  
Author(s):  
Peng Xu ◽  
Tao Zhou ◽  
Ning Chen ◽  
Juan Chen ◽  
Zhongguan Fu

Abstract Heat transfer coefficient has an important influence on the flow and heat transfer of supercritical water in the core channels. The effects of different factors and their interactions on the heat transfer coefficient of the supercritical water were studied by full factorial experimental design method, such as pressure, mass flow rate, heat flux, and inlet temperature. The results show that: Within the range of the tested working conditions, effect D (inlet temperature), effect B (mass flow rate) and effect A (pressure) had a significant impact on the heat transfer coefficient, where the percentage contribution of effect D was 48.21%; effect B was 21.58%; effect A was 15.1%. The percentage contribution of other factors and their interactions on the heat transfer coefficient of the supercritical water can be ignored. At the same time, a prediction formula of heat transfer coefficient on supercritical water was fitted, and it was found that the prediction error of this formula conformed to the assumption of normality, and the prediction error was 10.5%.


This experimental investigation aims to study the effect of inlet fluid on flow and heat transfer characteristics for buoyancy driven flow in square tube fitted with twisted strips. Twist pitch, heat supply, inclination of the tube and Inlet fluid temperature were changed during experimentation. The study revealed that with increase in pitch the percentage enhancement in heat transfer coefficient decreases. With decrease in the pitch the flow rate decreases. Moreover with increase in inlet fluid temperature both heat transfer coefficient and flow rate tends to decrease. Perhaps it is due to higher heat loss at the tube surface which results in reduction in Rayleigh number.


Author(s):  
Peng Xu ◽  
Tao Zhou ◽  
Jialei Zhang ◽  
Juan Chen ◽  
Zhongguan Fu

Abstract There are many factors that can affect the heat transfer coefficient (HTC) of supercritical water in forced and natural circulation. The correlation between the factors with the HTC under different circulation modes has an important influence on the reactor core design. By extracting the experimental data of supercritical water in forced circulation and natural circulation, the grey correlation model was used to analyze the relational degree between these factors with HTC. The results show that: Under the condition of forced circulation, there is a positive correlation between the inlet temperature, mass flow velocity, the thickness of the grid body with the HTC of supercritical water, and the order is: mass flow velocity > inlet temperature > the thickness of the grid body; there is a negative correlation between the pressure, heat flux with the heat transfer coefficient of supercritical water, and the order is: pressure > heat flux. Under the condition of natural circulation, there is a positively correlation between heating power, inlet temperature and circulation flow rate with HTC, and the order of magnitude is: circulation flow rate > heating power > inlet temperature; diameter and pressure are negatively correlated with heat transfer coefficient, and the order of magnitude is: pressure > diameter. In the two circulation modes, mass flow rate is an important factor affecting the heat transfer capacity of supercritical water, while the effect of heat flux on the heat transfer coefficient is contrary.


2021 ◽  
Vol 11 (2) ◽  
pp. 751
Author(s):  
Xuefeng Gao ◽  
Yanjun Zhang ◽  
Zhongjun Hu ◽  
Yibin Huang

As fluid passes through the fracture of an enhanced geothermal system, the flow direction exhibits distinct angular relationships with the geometric profile of the rough fracture. This will inevitably affect the heat transfer characteristics in the fracture. Therefore, we established a hydro-thermal coupling model to study the influence of the fluid flow direction on the heat transfer characteristics of granite single fractures and the accuracy of the numerical model was verified by experiments. Results demonstrate a strong correlation between the distribution of the local heat transfer coefficient and the fracture morphology. A change in the flow direction is likely to alter the transfer coefficient value and does not affect the distribution characteristics along the flow path. Increasing injection flow rate has an enhanced effect. Although the heat transfer capacity in the fractured increases with the flow rate, a sharp decline in the heat extraction rate and the total heat transfer coefficient is also observed. Furthermore, the model with the smooth fracture surface in the flow direction exhibits a higher heat transfer capacity compared to that of the fracture model with varying roughness. This is attributed to the presence of fluid deflection and dominant channels.


2019 ◽  
Vol 108 ◽  
pp. 01003
Author(s):  
Jan Taler ◽  
Piotr Dzierwa ◽  
Magdalena Jaremkiewicz ◽  
Dawid Taler ◽  
Karol Kaczmarski ◽  
...  

Thick-wall components of the thermal power unit limit maximum heating and cooling rates during start-up or shut-down of the unit. A method of monitoring the thermal stresses in thick-walled components of thermal power plants is presented. The time variations of the local heat transfer coefficient on the inner surface of the pressure component are determined based on the measurement of the wall temperature at one or six points respectively for one- and three-dimensional unsteady temperature fields in the component. The temperature sensors are located close to the internal surface of the component. A technique for measuring the fastchanging fluid temperature was developed. Thermal stresses in pressure components with complicated shapes can be computed using FEM (Finite Element Method) based on experimentally estimated fluid temperature and heat transfer coefficient


2004 ◽  
Vol 10 (5) ◽  
pp. 345-354 ◽  
Author(s):  
Jan Dittmar ◽  
Achmed Schulz ◽  
Sigmar Wittig

The demand of improved thermal efficiency and high power output of modern gas turbine engines leads to extremely high turbine inlet temperature and pressure ratios. Sophisticated cooling schemes including film cooling are widely used to protect the vanes and blades of the first stages from failure and to achieve high component lifetimes. In film cooling applications, injection from discrete holes is commonly used to generate a coolant film on the blade's surface.In the present experimental study, the film cooling performance in terms of the adiabatic film cooling effectiveness and the heat transfer coefficient of two different injection configurations are investigated. Measurements have been made using a single row of fanshaped holes and a double row of cylindrical holes in staggered arrangement. A scaled test model was designed in order to simulate a realistic distribution of Reynolds number and acceleration parameter along the pressure side surface of an actual turbine guide vane. An infrared thermography measurement system is used to determine highly resolved distribution of the models surface temperature. Anin-situcalibration procedure is applied using single embedded thermocouples inside the measuring plate in order to acquire accurate local temperature data.All holes are inclined 35° with respect to the model's surface and are oriented in a streamwise direction with no compound angle applied. During the measurements, the influence of blowing ratio and mainstream turbulence level on the adiabatic film cooling effectiveness and heat transfer coefficient is investigated for both of the injection configurations.


2019 ◽  
Vol 16 (1) ◽  
pp. 33-44 ◽  
Author(s):  
M.K. Islam ◽  
Md. Hasanuzzaman ◽  
N.A. Rahim ◽  
A. Nahar

Sustainable power generation, energy security, and global warming are the big challenges to the world today. These issues may be addressed through the increased usage of renewable energy resources and concentrated solar energy can play a vital role in this regard. The performance of a parabolic-trough collector’s receiver is here investigated analytically and experimentally using water based and therminol-VP1based CuO, ZnO, Al2O3, TiO2, Cu, Al, and SiC nanofluids. The receiver size has been optimized by a simulation program written in MATLAB. Thus, numerical results have been validated by experimental outcomes under same conditions using the same nanofluids. Increased volumetric concentrations of nanoparticle is found to enhance heat transfer, with heat transfer coefficient the maximum in W-Cu and VP1-SiC, the minimum in W-TiO2 and VP1-ZnO at 0.8 kg/s flow rate. Changing the mass flow rate also affects heat transfer coefficient. It has been observed that heat transfer coefficient reaches its maximum of 23.30% with SiC-water and 23.51% with VP1-SiC when mass-flow rate is increased in laminar flow. Heat transfer enhancement drops during transitions of flow from laminar to turbulent. The maximum heat transfer enhancements of 9.49% and 10.14% were achieved with Cu-water and VP1-SiC nanofluids during turbulent flow. The heat transfer enhancements of nanofluids seem to remain constant when compared with base fluids during either laminar flow or turbulent flow.


2019 ◽  
Vol 141 (3) ◽  
Author(s):  
Megan F. Watkins ◽  
Richard D. Gould

Particle-based heat transfer fluids for concentrated solar power (CSP) tower applications offer a unique advantage over traditional fluids, as they have the potential to reach very high operating temperatures. Gravity-driven dense granular flows through cylindrical tubes demonstrate potential for CSP applications and are the focus of the present study. The heat transfer capabilities of such a flow system were experimentally studied using a bench-scale apparatus. The effect of the flow rate and other system parameters on the heat transfer to the flow was studied at low operating temperatures (<200 °C), using the convective heat transfer coefficient and Nusselt number to quantify the behavior. For flows ranging from 0.015 to 0.09 m/s, the flow rate appeared to have negligible effect on the heat transfer. The effect of temperature on the flow's heat transfer capabilities was also studied, examining the flows at temperatures up to 1000 °C. As expected, the heat transfer coefficient increased with the increasing temperature due to enhanced thermal properties. Radiation did not appear to be a key contributor for the small particle diameters tested (approximately 300 μm in diameter) but may play a bigger role for larger particle diameters. The experimental results from all trials corroborate the observations of other researchers; namely, that particulate flows demonstrate inferior heat transfer as compared with a continuum flow due to an increased thermal resistance adjacent to the tube wall resulting from the discrete nature of the flow.