Effect of Insertion of a Heat Flux Gage Into a High Temperature Cylindrical Blackbody Cavity on the Gage

Author(s):  
Amanie N. Abdelmessih ◽  
Thomas J. Horn

Detailed transient thermal models have been developed to simulate a heat flux gage calibration process capable of generating high heat flux levels. These heat flux levels are of interest to the reciprocating and gas turbine engine industries as well as the aerospace industry. The transient models are based on existing, experimentally validated steady state models of a cylindrical blackbody calibration system. The steady state models were modified to include insertion of a heat flux gage into the hot zone of the calibration system, time-varying electrical current that passes through the resistance heated blackbody, and the resulting heating of the heat flux gage. Heat fluxes computed using detailed transient models were compared to experimental measurements. The calculated and measured transient heat fluxes agreed to within 2 percent, indicating that the models had captured the physical phenomena in the transient calibration. The predicted and measured transient heat fluxes were also compared for two different blackbody configurations. The effect of convection on the blackbody extension was evaluated and found to be a minor factor.

2014 ◽  
Vol 136 (4) ◽  
Author(s):  
Ram Ranjan ◽  
Joseph E. Turney ◽  
Charles E. Lents ◽  
Virginia H. Faustino

Thermoelectric (TE) coolers work on the Seebeck effect, where an electrical current is used to drive a heat flux against a temperature gradient. They have applications for active cooling of electronic devices but have low coefficients of performance (COP < 1) at high heat fluxes (>10 W/cm2, dT = 15 K). While the active elements (TE material) in a TE cooling module lead to cooling, the nonactive elements, such as the electrical leads and headers, cause joule heating and decrease the coefficient of performance. A conventional module design uses purely horizontal leads and vertical active elements. In this work, we numerically investigate trapezoidal leads with angled active elements as a method to improve cooler performance in terms of lower parasitic resistance, higher packing fraction and higher reliability, for both supperlattice thin-film and bulk TE materials. For source and sink side temperatures of 30 °C and 45 °C, we show that, for a constant packing fraction, defined as the ratio of active element area to the couple base area, trapezoidal leads decrease electrical losses but also increase thermal resistance. We also demonstrate that trapezoidal leads can be used to increase the packing fraction to values greater than one, leading to a two times increase in heat pumping capacity. Structural analysis shows a significant reduction in both tensile and shear stresses in the TE modules with trapezoidal leads. Thus, the present work provides a pathway to engineer more reliable thermoelectric coolers (TECs) and improve their efficiency by >30% at a two times higher heat flux as compared to the state-of-the-art.


Author(s):  
Ram Ranjan ◽  
Joseph E. Turney ◽  
Chuck E. Lents

Thermoelectric (TE) coolers work on the Seebeck effect, where an electrical current is used to drive a heat flux against a temperature gradient. They have applications for active cooling of electronic devices but have low coefficients of performance (COP<1) at high heat fluxes (>10 W/cm2). While the active elements (thermoelectric material) in a TE cooling module lead to cooling, the non-active elements, such as the electrical leads and headers, cause joule heating and decrease the coefficient of performance. A conventional module design uses purely horizontal leads and vertical active elements. In this work, we numerically investigate trapezoidal leads with angled active elements as a method to improve cooler performance for both supperlattice thin film and bulk thermoelectric materials. We show that, for a constant packing fraction, defined as the ratio of active element area to the couple base area, trapezoidal leads decrease electrical losses but also increase thermal resistance. We also demonstrate that trapezoidal leads can be used to increase the packing fraction to values greater than one, leading to a two times increase in heat pumping capacity. Thus the present work provides a pathway to improve the efficiency of the state-of-the-art thermoelectric coolers by > 30% at a two times higher heat flux.


Author(s):  
Rongliang Zhou ◽  
Juan Catano ◽  
Tiejun Zhang ◽  
John T. Wen ◽  
Greg J. Michna ◽  
...  

Steady-state modeling and analysis of a two-loop cooling system for high heat flux removal applications are studied. The system structure proposed consists of a primary pumped loop and a vapor compression cycle (VCC) as the secondary loop to which the pumped loop rejects heat. The pumped loop consists of evaporator, condenser, pump, and bladder liquid accumulator. The pumped loop evaporator has direct contact with the heat generating device and CHF must be higher than the imposed heat fluxes to prevent device burnout. The bladder liquid accumulator adjusts the pumped loop pressure level and, hence, the subcooling of the refrigerant to avoid pump cavitation and to achieve high critical heat flux (CHF) in the pumped loop evaporator. The vapor compression cycle of the two-loop cooling system consists of evaporator, liquid accumulator, compressor, condenser and electronic expansion valve. It is coupled with the pumped loop through a fluid-to-fluid heat exchanger that serves as both the vapor compression cycle evaporator and the pumped loop condenser. The liquid accumulator of the vapor compression cycle regulates the cycle active refrigerant charge and provides saturated vapor to the compressor at steady state. The heat exchangers are modeled with the mass, momentum, and energy balance equations. Due to the projected incorporation of microchannels in the pumped loop to enhance the heat transfer in heat sinks, the momentum equation, rarely seen in previous refrigeration system modeling efforts, is included to capture the expected significant microchannel pressure drop witnessed in previous experimental investigations. Electronic expansion valve, compressor, pump, and liquid accumulators are modeled as static components due to their much faster dynamics compared with heat exchangers. The steady-state model can be used for static system design that includes determining the total refrigerant charge in the vapor compression cycle and the pumped loop to accommodate the varying heat load, sizing of various components, and parametric studies to optimize the operating conditions for a given heat load. The effect of pumped loop pressure level, heat exchangers geometries, pumped loop refrigerant selection, and placement of the pump (upstream or downstream of the evaporator) are studied. The two-loop cooling system structure shows both improved coefficient of performance (COP) and CHF overthe single loop vapor compression cycle investigated earlier by authors for high heat flux removal.


Author(s):  
Jensen Hoke ◽  
Todd Bandhauer ◽  
Jack Kotovsky ◽  
Julie Hamilton ◽  
Paul Fontejon

Liquid-vapor phase change heat transfer in microchannels offers a number of significant advantages for thermal management of high heat flux laser diodes, including reduced flow rates and near constant temperature heat rejection. Modern laser diode bars can produce waste heat loads >1 kW cm−2, and prior studies show that microchannel flow boiling heat transfer at these heat fluxes is possible in very compact heat exchanger geometries. This paper describes further performance improvements through area enhancement of microchannels using a pyramid etching scheme that increases heat transfer area by ∼40% over straight walled channels, which works to promote heat spreading and suppress dry-out phenomenon when exposed to high heat fluxes. The device is constructed from a reactive ion etched silicon wafer bonded to borosilicate to allow flow visualization. The silicon layer is etched to contain an inlet and outlet manifold and a plurality of 40μm wide, 200μm deep, 2mm long channels separated by 40μm wide fins. 15μm wide 150μm long restrictions are placed at the inlet of each channel to promote uniform flow rate in each channel as well as flow stability in each channel. In the area enhanced parts either a 3μm or 6μm sawtooth pattern was etched vertically into the walls, which were also scalloped along the flow path with the a 3μm periodicity. The experimental results showed that the 6μm area-enhanced device increased the average maximum heat flux at the heater to 1.26 kW cm2 using R134a, which compares favorably to a maximum of 0.95 kw cm2 dissipated by the plain walled test section. The 3μm area enhanced test sections, which dissipated a maximum of 1.02 kW cm2 showed only a modest increase in performance over the plain walled test sections. Both area enhancement schemes delayed the onset of critical heat flux to higher heat inputs.


2020 ◽  
Vol 25 ◽  
pp. 100816
Author(s):  
V.P. Budaev ◽  
S.D. Fedorovich ◽  
A.V. Dedov ◽  
A.V. Karpov ◽  
A.T. Komov ◽  
...  

Author(s):  
P. E. Phelan ◽  
Y. Gupta ◽  
H. Tyagi ◽  
R. Prasher ◽  
J. Cattano ◽  
...  

Increasingly, military and civilian applications of electronics require extremely high heat fluxes, on the order of 1000 W/cm2. Thermal management solutions for these severe operating conditions are subject to a number of constraints, including energy consumption, controllability, and the volume or size of the package. Calculations indicate that the only possible approach to meeting this heat flux condition, while maintaining the chip temperature below 50 °C, is to utilize refrigeration. Here we report an initial optimization of the refrigeration system design. Because the outlet quality of the fluid leaving the evaporator must be held to approximately less than 20%, in order to avoid reaching critical heat flux, the refrigeration system design is dramatically different from typical configurations for household applications. In short, a simple vapor-compression cycle will require excessive energy consumption, largely because of the superheat required to return the refrigerant to its vapor state before the compressor inlet. A better design is determined to be a “two-loop” cycle, in which the vapor-compression loop is coupled thermally to a primary loop that directly cools the high-heat-flux chip.


1998 ◽  
Vol 120 (2) ◽  
pp. 365-370 ◽  
Author(s):  
K. H. Haddad ◽  
F. B. Cheung

Steady-state nucleate boiling heat transfer experiments in saturated and subcooled water were conducted. The heating surface was a 0.305 m hemispherical aluminum vessel heated from the inside with water boiling on the outside. It was found that subcooling had very little effect on the nucleate boiling curve in the high heat flux regime where latent heat transport dominated. On the other hand, a relatively large effect of subcooling was observed in the low-heat-flux regime where sensible heat transport was important. Photographic records of the boiling phenomenon and the bubble dynamics indicated that in the high-heat-flux regime, boiling in the bottom center region of the vessel was cyclic in nature with a liquid heating phase, a bubble nucleation and growth phase, a bubble coalescence phase, and a large vapor mass ejection phase. At the same heat flux level, the size of the vapor masses was found to decrease from the bottom center toward the upper edge of the vessel, which was consistent with the increase observed in the critical heat flux in the flow direction along the curved heating surface.


Author(s):  
Clayton L. Hose ◽  
Dimeji Ibitayo ◽  
Lauren M. Boteler ◽  
Jens Weyant ◽  
Bradley Richard

This work presents a demonstration of a coefficient of thermal expansion (CTE) matched, high heat flux vapor chamber directly integrated onto the backside of a direct bond copper (DBC) substrate to improve heat spreading and reduce thermal resistance of power electronics modules. Typical vapor chambers are designed to operate at heat fluxes > 25 W/cm2 with overall thermal resistances < 0.20 °C/W. Due to the rising demands for increased thermal performance in high power electronics modules, this vapor chamber has been designed as a passive, drop-in replacement for a standard heat spreader. In order to operate with device heat fluxes >500 W/cm2 while maintaining low thermal resistance, a planar vapor chamber is positioned onto the backside of the power substrate, which incorporates a specially designed wick directly beneath the active heat dissipating components to balance liquid return and vapor mass flow. In addition to the high heat flux capability, the vapor chamber is designed to be CTE matched to reduce thermally induced stresses. Modeling results showed effective thermal conductivities of up to 950 W/m-K, which is 5 times better than standard copper-molybdenum (CuMo) heat spreaders. Experimental results show a 43°C reduction in device temperature compared to a standard solid CuMo heat spreader at a heat flux of 520 W/cm2.


2001 ◽  
Vol 56-57 ◽  
pp. 205-210 ◽  
Author(s):  
Y Kubota ◽  
N Noda ◽  
A Sagara ◽  
R Sakamoto ◽  
K Yamazaki ◽  
...  

2015 ◽  
Vol 137 (4) ◽  
Author(s):  
Craig Green ◽  
Peter Kottke ◽  
Xuefei Han ◽  
Casey Woodrum ◽  
Thomas Sarvey ◽  
...  

Three-dimensional (3D) stacked electronics present significant advantages from an electrical design perspective, ranging from shorter interconnect lengths to enabling heterogeneous integration. However, multitier stacking exacerbates an already difficult thermal problem. Localized hotspots within individual tiers can provide an additional challenge when the high heat flux region is buried within the stack. Numerous investigations have been launched in the previous decade seeking to develop cooling solutions that can be integrated within the 3D stack, allowing the cooling to scale with the number of tiers in the system. Two-phase cooling is of particular interest, because the associated reduced flow rates may allow reduction in pumping power, and the saturated temperature condition of the coolant may offer enhanced device temperature uniformity. This paper presents a review of the advances in two-phase forced cooling in the past decade, with a focus on the challenges of integrating the technology in high heat flux 3D systems. A holistic approach is applied, considering not only the thermal performance of standalone cooling strategies but also coolant selection, fluidic routing, packaging, and system reliability. Finally, a cohesive approach to thermal design of an evaporative cooling based heat sink developed by the authors is presented, taking into account all of the integration considerations discussed previously. The thermal design seeks to achieve the dissipation of very large (in excess of 500 W/cm2) background heat fluxes over a large 1 cm × 1 cm chip area, as well as extreme (in excess of 2 kW/cm2) hotspot heat fluxes over small 200 μm × 200 μm areas, employing a hybrid design strategy that combines a micropin–fin heat sink for background cooling as well as localized, ultrathin microgaps for hotspot cooling.