Heat Transfer Enhancement in Compact Phase Change Microchannel Heat Exchangers for High Flux Laser Diodes

Author(s):  
Jensen Hoke ◽  
Todd Bandhauer ◽  
Jack Kotovsky ◽  
Julie Hamilton ◽  
Paul Fontejon

Liquid-vapor phase change heat transfer in microchannels offers a number of significant advantages for thermal management of high heat flux laser diodes, including reduced flow rates and near constant temperature heat rejection. Modern laser diode bars can produce waste heat loads >1 kW cm−2, and prior studies show that microchannel flow boiling heat transfer at these heat fluxes is possible in very compact heat exchanger geometries. This paper describes further performance improvements through area enhancement of microchannels using a pyramid etching scheme that increases heat transfer area by ∼40% over straight walled channels, which works to promote heat spreading and suppress dry-out phenomenon when exposed to high heat fluxes. The device is constructed from a reactive ion etched silicon wafer bonded to borosilicate to allow flow visualization. The silicon layer is etched to contain an inlet and outlet manifold and a plurality of 40μm wide, 200μm deep, 2mm long channels separated by 40μm wide fins. 15μm wide 150μm long restrictions are placed at the inlet of each channel to promote uniform flow rate in each channel as well as flow stability in each channel. In the area enhanced parts either a 3μm or 6μm sawtooth pattern was etched vertically into the walls, which were also scalloped along the flow path with the a 3μm periodicity. The experimental results showed that the 6μm area-enhanced device increased the average maximum heat flux at the heater to 1.26 kW cm2 using R134a, which compares favorably to a maximum of 0.95 kw cm2 dissipated by the plain walled test section. The 3μm area enhanced test sections, which dissipated a maximum of 1.02 kW cm2 showed only a modest increase in performance over the plain walled test sections. Both area enhancement schemes delayed the onset of critical heat flux to higher heat inputs.

Author(s):  
Qingjun Cai ◽  
Avijit Bhunia ◽  
Yuan Zhao

Silicon is the major material in IC manufacture. It has high thermal conductivity and is compatible with precision micro-fabrication. It also has decent thermal expansion coefficient to most semiconductor materials. These characteristics make it an ideally underlying material for fabricating micro/mini heat pipes and their wick structures. In this paper, we focus our research investigations on high heat flux phase change capacity of the silicon wick structures. The experimental wick sample is composed of silicon pillars 320μm in height and 30 ∼ 100μm in diameter. In a stainless steel test chamber, synchronized visualizations and measurements are performed to crosscheck experimental phenomena and data. Using the mono-wick structure with large silicon pillar of 100μm in diameter, the phase change on the silicon wick structure reaches its maximum heat flux at 1,130W/cm2 over a 2mm×2mm heating area. The wick structure can fully utilize the wick pump capability to supply liquid from all 360° directions to the center heating area. In contrast, the large heating area and fine silicon pillars 10μm in diameter significantly reduces liquid transport capability and suppresses generation of nucleate boiling. As a result, phase change completely relies on evaporation, and the CHF of the wick structure is reduced to 180W/cm2. An analytical model based on high heat flux phase change of mono-porous wick structures indicates that heat transfer capability is subjected to the ratio between the wick particle radius and the heater dimensions, as well as vapor occupation ratio of the porous volume. In contrast, phase change heat transfer coefficients of the wick structures essentially reflect material properties of wick structure and mechanism of two-phase interactions within wick structures.


Author(s):  
Jianwei Gao ◽  
Hongxia Li ◽  
Saif Almheiri ◽  
TieJun Zhang

Thermal management is essential to compact devices particularly for high heat flux removal applications. As a popular thermal technology, refrigeration cooling is able to provide relatively high heat flux removal capability and uniform device surface temperature. In a refrigeration cycle, the performance of evaporator is extremely important to the overall cooling efficiency. In a well-designed evaporator, effective flow boiling heat transfer can be achieved whereas the critical heat flux (CHF) or dryout condition must be avoided. Otherwise the device surface temperature would rise significantly and cause device burnout due to the poor heat transfer performance of film boiling. In order to evaluate the influence of varying imposed heat fluxes, saturated flow boiling in the evaporator is systematically studied. The complete refrigerant flow boiling hysteresis between the imposed heat flux and the exit wall superheat is characterized. Upon the occurrence of CHF at the evaporator wall exit, the wall heat flux redistributes due to the axial wall heat conduction, which drives the dryout point to propagate upstream in the evaporator. As a result, a significant amount of thermal energy is stored in the evaporator wall. While the heat flux starts decreasing, the dryout point moves downstream and closer to the exit. The stored heat in the wall dissipates slowly and leads to the delay in rewetting or quenching, which is the key to understand and predict the flow boiling hysteresis. In order to reveal the transient heat releasing mechanism, an augmented separated-flow model is developed to predict the moving rewetting point and minimum heat flux at the evaporator exit, and the model predictions are further validated by experimental data from a refrigeration cooling testbed.


2019 ◽  
Vol 196 ◽  
pp. 00062
Author(s):  
Vladimir Kuznetsov ◽  
Alisher Shamirzaev ◽  
Alexander Mordovskoy

This paper presents the results of an experimental study of the heat transfer during flow boiling of refrigerant R236fa in a horizontal microchannel heat sink. The experiments were performed using closed loop that re-circulates coolant. Microchannel heat exchanger that contains two microchannels with 2x0.4 mm cross-section was used as the test section. The dependence of average heat flux on wall superheat and critical heat flux were measured in the range of mass fluxes from 600 to 1600 kg/m2s and in the range of heat fluxes from 5 to 120 W/cm2. For heat flux greater than 60 W/cm2, nucleate boiling suppression has significant effect on the flow boiling heat transfer, and this leads to decrease of the heat transfer coefficient with heat flux grows.


2021 ◽  
Author(s):  
Ji Hwan Lim ◽  
Minkyu Park

Abstract The onset of nucleate boiling (ONB) is the point at which the heat transfer mechanism in fluids changes and is one of the thermo-hydraulic factors that must be considered when establishing a cooling system operation strategy. Because the high heat flux of several MW/m2, which is loaded within a tokamak, is applied under a one-side heating condition, it is necessary to determine a correlative relation that can predict ONB under special heating conditions. In this study, the ONB of a one-side-heated screw tube was experimentally analyzed via a subcooled flow boiling experiment. The helical nut structure of the screw tube flow path wall allows for improved heat transfer performance relative to smooth tubes, providing a screw tube with a 53.98% higher ONB than a smooth tube. The effects of the system parameters on the ONB heat flux were analyzed based on the changes in the heat transfer mechanism, with the results indicating that the flow rate and degree of subcooling are proportional to the ONB heat flux because increasing these factors improves the forced convection heat transfer and increases the condensation rate, respectively. However, it was observed that the liquid surface tension and latent heat decrease as the pressure increases, leading to a decrease in the ONB heat flux. An evaluation of the predictive performance of existing ONB correlations revealed that most have high error rates because they were developed based on ONB experiments on micro-channels or smooth tubes and not under one-side high heat load conditions. To address this, we used dimensional analysis based on Python code to develop new ONB correlations that reflect the influence of system parameters.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Bharath Ramakrishnan ◽  
Yaser Hadad ◽  
Sami Alkharabsheh ◽  
Paul R. Chiarot ◽  
Bahgat Sammakia

Data center energy usage keeps growing every year and will continue to increase with rising demand for ecommerce, scientific research, social networking, and use of streaming video services. The miniaturization of microelectronic devices and an increasing demand for clock speed result in high heat flux systems. By adopting direct liquid cooling, the high heat flux and high power demands can be met, while the reliability of the electronic devices is greatly improved. Cold plates which are mounted directly on to the chips facilitate a lower thermal resistance path originating from the chip to the incoming coolant. An attempt was made in the current study to characterize a commercially available cold plate which uses warm water in carrying the heat away from the chip. A mock package mimicking a processor chip with an effective heat transfer area of 6.45 cm2 was developed for this study using a copper block heater arrangement. The thermo-hydraulic performance of the cold plates was investigated by conducting experiments at varying chip power, coolant flow rates, and coolant temperature. The pressure drop (ΔP) and the temperature rise (ΔT) across the cold plates were measured, and the results were presented as flow resistance and thermal resistance curves. A maximum heat flux of 31 W/cm2 was dissipated at a flow rate of 13 cm3/s. A resistance network model was used to calculate an effective heat transfer coefficient by revealing different elements contributing to the total resistance. The study extended to different coolant temperatures ranging from 25 °C to 45 °C addresses the effect of coolant viscosity on the overall performance of the cold plate, and the results were presented as coefficient of performance (COP) curves. A numerical model developed using 6SigmaET was validated against the experimental findings for the flow and thermal performance with minimal percentage difference.


2008 ◽  
Vol 51 (21-22) ◽  
pp. 5400-5414 ◽  
Author(s):  
Bruno Agostini ◽  
John Richard Thome ◽  
Matteo Fabbri ◽  
Bruno Michel ◽  
Daniele Calmi ◽  
...  

Author(s):  
Hailei Wang ◽  
Richard Peterson

Flow boiling and heat transfer enhancement in four parallel microchannels using a dielectric working fluid, HFE 7000, was investigated. Each channel was 1000 μm wide and 510 μm high. A unique channel surface enhancement technique via diffusion bonding a layer of conductive fine wire mesh onto the heating wall was developed. According to the obtained flow boiling curves for both the bare and mesh channels, the amount of wall superheat was significantly reduced for the mesh channel at all stream-wise locations. This indicated that the nucleate boiling in the mesh channel was enhanced due to the increase of nucleation sites the mesh introduced. Both the nucleate boiling dominated and convective evaporation dominated regimes were identified. In addition, the overall trend for the flow boiling heat transfer coefficient, with respect to vapor quality, was increasing until the vapor quality reached approximately 0.4. The critical heat flux (CHF) for the mesh channel was also significantly higher than that of the bare channel in the low vapor quality region. Due to the fact of how the mesh was incorporated into the channels, no pressure drop penalty was identified for the mesh channels. Potential applications for this kind of mesh channel include high heat-flux electronic cooling systems and various energy conversion systems.


Author(s):  
Satish G. Kandlikar

Research efforts on flow boiling in microchannels were focused on stabilizing the flow during the early part of the last decade. After achieving that goal through inlet restrictors and distributed nucleation sites, the focus has now shifted on improving its performance for high heat flux dissipation. The recent worldwide efforts described in this paper are aimed at increasing the critical heat flux (CHF) while keeping the pressure drop low, with an implicit goal of dissipating 1 kW/cm2 for meeting the high-end target in electronics cooling application. The underlying mechanisms in these studies are identified and critically evaluated for their potential in meeting the high heat flux dissipation goals. Future need to simultaneously increase the CHF and the heat transfer coefficient (HTC) has been identified and hierarchical integration of nanoscale and microscale technologies is deemed necessary for developing integrated pathways toward meeting this objective.


Author(s):  
Ankit Kalani ◽  
Satish G. Kandlikar

Flow boiling with microchannel can dissipate high heat fluxes at low surface temperature difference. A number of issues, such as instabilities, low critical heat flux (CHF) and low heat transfer coefficients, have prevented it from reaching its full potential. A new design incorporating open microchannels with uniform and tapered manifold (OMM) was shown to mitigate these issues successfully. Distilled, degassed water at 80 mL/min is used as the working fluid. Plain and open microchannel surfaces are used as the test sections. Heat transfer and pressure drop performance for uniform and tapered manifold with both the surfaces are discussed. A low pressure drop of 7.5 kPa is obtained with tapered manifold and microchannel chip at a heat flux of 263 W/cm2 without reaching CHF. The pressure drop data is further compared with the homogenous model and the initial results are presented.


Author(s):  
Qian Li ◽  
Wei Wang ◽  
Chris Oshman ◽  
Benoit Latour ◽  
Chen Li ◽  
...  

Thermal management plays an important role in both high power electronics and energy conversion systems. A key issue in thermal management is the dissipation of the high heat flux generated by functional components. In this paper, various microstructures, nanostructures and hybrid micro/nano-structures were successfully fabricated on copper (Cu) surfaces, and the corresponding pool boiling heat transfer performance was systematically studied. It is found that the critical heat flux (CHF) of hybrid structured surfaces is about 15% higher than that of the surfaces with nanowires only and micro-pillars only. More importantly, the superheat at CHF for the hybrid structured surface is much smaller than that of the micro-pillared surface (about 35%), and a maximum heat transfer coefficient (HTC) of about 90,000W/m2K is obtained. Compared with the known best pool boiling performance on biporous media, a much larger HTC and much lower superheat at a heat flux of 250W/cm2 have been obtained on the novel hybrid-structured surfaces.