Critical Heat Flux During Submerged Jet Impingement Boiling of Saturated Water at Sub-Atmospheric Conditions

Author(s):  
Ruander Cardenas ◽  
Vinod Narayanan

Experimental data for critical heat flux (CHF) during submerged jet impingement boiling of saturated water at sub-atmospheric conditions is presented. Experiments are performed at three sub-atmospheric pressures of 0.176 bar, 0.276 bar, and 0.477 bar with corresponding fluid saturation temperatures of about 57.3 °C, 67.2 °C, and 80.2 °C. Jet exit Reynolds numbers ranging from 0 to 14,000 are considered for two different heater surface finishes at a fixed nozzle to surface spacing of six nozzle diameters. CHF correlations from literature on jet impingement boiling are compared against the experimental data and found to poorly predict CHF under the conditions considered. A CHF correlation that captures the entire experimental data set within an average error of ±3 percent and a maximum error of ±13 percent is developed to serve as a predictive tool for the range of conditions examined.

2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Ruander Cardenas ◽  
Vinod Narayanan

Critical heat flux (CHF) characteristics in submerged jet impingement boiling of water on a heated copper surface are investigated at subatmospheric conditions. Data are reported at a fixed surface-to-nozzle diameter ratio of 23.8 and a fixed surface-to-nozzle height of 6 nozzle diameters. Three subatmospheric pressures of 0.176 bars, 0.276 bars, and 0.477 bars are considered, corresponding to fluid saturation temperatures of 57.3 °C, 67.2 °C, and 80.2 °C and liquid-to-vapor density ratios of 8502, 5544, and 3295, respectively. At each pressure, CHF for varying jet Reynolds numbers (Re) in the range 0–14,000 are compared for two different surface finishes of roughness average values of 123 nm and 33 nm. The CHF enhancement observed with increasing Re is depicted in a nondimensional CHF map. Existing correlations available in the literature, which are out of range of the current experimental conditions, are found to poorly predict the obtained CHF data. A CHF correlation that captures the entire experimental data set within an average error of ±3% and a maximum error of ±13% is developed. The effect of fluid subcooling on submerged jet CHF is studied at the lowest pressure of 0.176 bars. Subcooled jet CHF is found to be well predicted from saturated jet CHF by using a typical subcooled pool boiling CHF correction factor.


Author(s):  
Ruander Cardenas ◽  
Vinod Narayanan

Data from an extensive experimental study of submerged jet impingement boiling performed with water at sub-atmospheric pressures and with FC-72 at atmospheric pressure are used to develop a predictive critical heat flux (CHF) correlation for use in thermal management of electronic components. The configuration was that of a circular submerged jet impinging on a high-thermal-capacity copper surface with a standoff distance of 6 nozzle diameters. Varied parameters included the Reynolds numbers (Re) from 0 (pool boiling) to 14000, surface-to-nozzle diameter ratios (by varying the nozzle diameter) from 25 to 6, system pressures (0.2, 0.3, 0.5, 1 bar), surface roughness (123 nm, 33 nm), and system subcooling. CHF is found to increase with Re, system pressure, subcooling, and roughness and decreases with increase in nozzle diameter for a fixed Re. Comparison with correlations in literature indicated that data of sub-atmospheric jet impingement of water were poorly predicted by existing correlations while the Monde and Katto correlation [1] was found to predict the atmospheric jet impingement data with FC-72 within 10 percent at Re >4000. Data from the experiments were fitted to a submerged forced convective CHF model proposed by Haramura and Katto [2] to develop a correlation for submerged jet impingement boiling over a wide range of density ratios. Using this model, the entire CHF dataset from experiments can be predicted with a maximum error of less than 11 percent and an average error of less than 2.6 percent.


Author(s):  
Ruander Cardenas ◽  
Preeti Mani ◽  
Vinod Narayanan

An experimental study of mini-jet impingement boiling is presented for saturated conditions. Unique to this study is documentation of boiling characteristics of a submerged water jet under sub-atmospheric conditions. Data are reported at a fixed nozzle-to-surface distance that corresponds to a monotonic decrease in heat transfer coefficient for single-phase jet impingement. A mini nozzle is used in the present study with an internal diameter of 1.16 mm. Experiments are performed at three sub-atmospheric pool pressures of 0.2 bar, 0.3 bar and 0.5 bar. At each pressure, jet impingement boiling at four Reynolds numbers are characterized and compared with the pool boiling heat transfer. Enhancements in critical heat flux with increasing Re are observed for all pressures.


Author(s):  
Ruander Cardenas ◽  
Preeti Mani ◽  
Vinod Narayanan

An experimental study of mini-jet impingement boiling is presented for saturated and subcooled conditions. Unique to this study is the documentation of boiling curves of submerged water jet impingement under sub-atmospheric conditions. Data are reported at a single sub-atmospheric pool pressure of 0.176 bar and for a fixed nozzle-to-surface distance of six jet diameters. A mini nozzle is used in the present study with an internal diameter of 1.16 mm. Jet impingement boiling at Reynolds numbers in the range of 0 to 6,800 are characterized and contrasted for both saturated and subcooled conditions. Enhancements in critical heat flux with increasing Re are observed for both saturated and subcooled conditions, with the subcooled condition of 17 °C showing approximately 2.3 times the critical heat flux as that observed for saturated conditions. Critical heat flux for subcooled jet impingement boiling is well predicted from the saturated critical heat flux data by a modified subcooled pool boiling CHF correlation presented by Inoue et al. [1]. The effect of surface finish on pool boiling is also reported.


Author(s):  
Preeti Mani ◽  
Ruander Cardenas ◽  
Vinod Narayanan

Submerged jet impingement boiling has the potential to enhance pool boiling heat transfer rates. In most practical situations, the surface could consist of multiple heat sources that dissipate heat at different rates resulting in a surface heat flux that is non-uniform. This paper discusses the effect of submerged jet impingement on the wall temperature characteristics and heat transfer for a non-uniform heat flux. A mini-jet is caused to impinge on a polished silicon surface from a nozzle having an inner diameter of 1.16 mm. A 25.4 mm diameter thin-film circular serpentine heater, deposited on the bottom of the silicon wafer, is used to heat the surface. Deionized degassed water is used as the working fluid and the jet and pool are subcooled by 20°C. Voltage drop between sensors leads drawn from the serpentine heater are used to identify boiling events. Heater surface temperatures are determined using infrared thermography. High-speed movies of the boiling front are recorded and used to interpret the surface temperature contours. Local heat transfer coefficients indicate significant enhancement upto radial locations of 2.6 jet diameters for a Reynolds number of 2580 and upto 6 jet diameters for a Reynolds number of 5161.


2004 ◽  
Vol 126 (2) ◽  
pp. 179-183 ◽  
Author(s):  
Zhen-Hua Liu ◽  
Tie-Feng Tong ◽  
Yu-Hao Qiu

An experimental investigation was carried out for predicting the critical heat flux (CHF) of steady boiling for a round subcooled water jet impingement on the flat stagnation zone. The experimental data were measured in a steady nucleate boiling state. Three main influencing parameters, i.e., subcooling, impact velocity and jet nozzle size were widely changed and their effects on the critical heat flux were systemically studied. An empirical correlation was obtained using the experimental data over a wide experimental range for predicting the critical heat flux of steady boiling for a round subcooled water jet impingement on the flat stagnation zone.


2002 ◽  
Vol 124 (6) ◽  
pp. 1125-1130 ◽  
Author(s):  
Zhen-Hua Liu ◽  
Qun-Zhi Zhu

A theoretical analysis and an experimental investigation were carried out for predicting the critical heat flux (CHF) of convective boiling for a round saturated water jet impinging on the jet stagnation zone. The model of the maximum liquid subfilm thickness based on the Helmholtz instability is used to derive a semi-theoretical equation and the correlation factor was determined from the experimental data. Finally, a semi-theoretical correlation was proposed for predicting CHF of convective boiling for saturated water jet impinging on the jet stagnation zone.


Sign in / Sign up

Export Citation Format

Share Document