Critical Review of Early Age Cycling Effects on the Capacity of Pile to Sleeve Grouted Connections As Treated in ISO 19902

Author(s):  
Andi Merxhani ◽  
Jacob Fisker Jensen ◽  
Joao Caetano ◽  
Casper Klintø Christiansen

Abstract The treatment of early age cyclic loading (EAC) on pile-sleeve grouted connections is one of the challenging problems encountered in the design of offshore jacket structures. ISO 19902 appears to be the only offshore structural design code that quantifies the strength de-rating due to EAC. However, the mechanism of EAC considered in the ISO standard is little understood. Main provision is that the strength reduction due to EAC is considered to be linearly proportional to the compressive strength of the grout. This provision is conservatively applicable for medium strength grouts. However, it is over-conservative when modern high-performance grouts are used, and it can be further argued that it actually loses its physical meaning. Thus, a further investigation into the mechanics of the problem is deemed beneficial in order to understand better its underlying mechanism. Using existing experimental evidence and a simple mechanical model, it is shown that the EAC mechanism considered in ISO 19902 triggers the grout matrix failure mechanism of the grouted connections. This behavior is characteristic of segregating grout materials. The benefit of the approach followed is that it links the interpretation of EAC to the grout material properties. The phenomenon is then understood using methods and experimental results that are well established in concrete mechanics. After a comparison with existing experimental evidence on grouted connections and concrete members, it is suggested that the strength drop for the specific shearing mechanism is independent of the uniaxial compressive strength of the grout material.

2007 ◽  
Vol 348-349 ◽  
pp. 473-476
Author(s):  
Won Jun Park ◽  
Han Seung Lee ◽  
Ki Bong Park

It is well known that PC (polycarboxylate) agent is superior to other agents for the early-strength of concrete. Thus, this study investigates the development of mortar strength using various agents. To prove this, various factors were tested. Furthermore, this study measured compressive strength at the age of 18, 24, 36, 72, and 168 hours and gave a request text TG/DTA to observe minute structures. In addition, this study took pictures of minute structures using an SEM for each agent at the same age. According to the results, mortar using an early-strength PC agents is faster than a general water reducing AE agent, high performance PC agents, and other agents in the acceleration of hydration at the same early age. A TG/DTA test shows that the early-strength PC agents create more hydration products, such as Ca(OH)2, than others at the same age. The degree of pH in each agent is unrelated to the degree of hydration in mortar. An MIP analysis confirms these results. However, other methods are required the exact analysis of micro structures.


Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1829
Author(s):  
Gang Ling ◽  
Zhonghe Shui ◽  
Xu Gao ◽  
Tao Sun ◽  
Rui Yu ◽  
...  

In this research, iron ore tailing (IOT) is utilized as the cementitious material to develop an eco-friendly ultra-high performance concrete (UHPC). The UHPC mix is obtained according to the modified Andreasen and Andersen (MAA) packing model, and the applied dosage of IOT is 10%, 20%, and 30% (by weight), respectively. The calculated packing density of different mixtures is consistent with each other. Afterwards, the fresh and hardened performance of UHPC mixtures with IOT are evaluated. The results demonstrate that the workability of designed UHPC mixtures is increased with the incorporation of IOT. The heat flow at an early age of designed UHPC with IOT is attenuated, the compressive strength and auto shrinkage at an early age are consequently reduced. The addition of IOT promotes the development of long-term compressive strength and optimization of the pore structure, thus the durability of designed UHPC is still guaranteed. In addition, the ecological estimate results show that the utilization of IOT for the UHPC design can reduce the carbon emission significantly.


2012 ◽  
Vol 166-169 ◽  
pp. 1316-1320
Author(s):  
Ying Wei Yun ◽  
Qin Luo ◽  
Il Young Jang ◽  
Shan Shan Sun ◽  
Jia Wei Zhang

Ductility is important in the design of reinforced concrete structures. In seismic design of reinforced concrete members, it is necessary to allow for relatively large ductility so that the seismic energy is absorbed to avoid shear failure or significant degradation of strength even after yielding of reinforcing steels in the concrete member occurs. This paper aims to present the basic data for the ductility evaluation of reinforced HPC (high performance concrete) beams. Accordingly, 10 flexural tests were conducted on full-scale structural concrete beam specimens having concrete compressive strength of 40, 60, and 70 MPa. The test results were then reviewed in terms of flexural capacity and ductility. The effect of concrete compressive strength, tension steel ratio, and shear span to beam depth ratio on ductility were investigated experimentally.


PCI Journal ◽  
2020 ◽  
Vol 65 (6) ◽  
pp. 35-61
Author(s):  
Chungwook Sim ◽  
Maher Tadros ◽  
David Gee ◽  
Micheal Asaad

Ultra-high-performance concrete (UHPC) is a special concrete mixture with outstanding mechanical and durability characteristics. It is a mixture of portland cement, supplementary cementitious materials, sand, and high-strength, high-aspect-ratio microfibers. In this paper, the authors propose flexural design guidelines for precast, prestressed concrete members made with concrete mixtures developed by precasters to meet minimum specific characteristics qualifying it to be called PCI-UHPC. Minimum specified cylinder strength is 10 ksi (69 MPa) at prestress release and 18 ksi (124 MPa) at the time the member is placed in service, typically 28 days. Minimum flexural cracking and tensile strengths of 1.5 and 2 ksi (10 and 14 MPa), respectively, according to ASTM C1609 testing specifications are required. In addition, strain-hardening and ductility requirements are specified. Tensile properties are shown to be more important for structural optimization than cylinder strength. Both building and bridge products are considered because the paper is focused on capacity rather than demand. Both service limit state and strength limit state are covered. When the contribution of fibers to capacity should be included and when they may be ignored is shown. It is further shown that the traditional equivalent rectangular stress block in compression can still be used to produce satisfactory results in prestressed concrete members. A spreadsheet workbook is offered online as a design tool. It is valid for multilayers of concrete of different strengths, rows of reinforcing bars of different grades, and prestressing strands. It produces moment-curvature diagrams and flexural capacity at ultimate strain. A fully worked-out example of a 250 ft (76.2 m) span decked I-beam of optimized shape is given.


Alloy Digest ◽  
2005 ◽  
Vol 54 (3) ◽  

Abstract MoldStar 90 is a high-performance beryllium-free copper alloy for the blow-molding and injection-molding industries. This datasheet provides information on composition, physical properties, hardness, tensile properties, and compressive strength. It also includes information on machining, joining, and surface treatment. Filing Code: CU-732. Producer or source: Performance Alloys.


Alloy Digest ◽  
2005 ◽  
Vol 54 (2) ◽  

Abstract MoldStar 150 (formerly PAS 940) is a high performance copper alloy for the blow-molding and injection-molding industries. This datasheet provides information on composition, physical properties, tensile properties, and compressive strength. It also includes information on forming, machining, joining, and surface treatment. Filing Code: CU-729. Producer or source: Performance Alloys.


Sign in / Sign up

Export Citation Format

Share Document