Efficiency Optimization of Four Gas Turbine Power Plant Configurations

Author(s):  
Sultan Almodarra ◽  
Abdullah Alabdulkarem

Gas turbine power plants fueled by natural gas are common due to their quick start-up operation and low emissions compared with steam power plants that are directly fired. However, the efficiency of basic gas turbine power plant is considered low. Any improvement in the efficiency would result in fuel savings as well as reduction in CO2 emissions. One way to improve the efficiency is to utilize exhaust gas waste heat. Two waste heat utilization options were considered. The first option was to run a steam power plant (i.e. combined cycle power plant) while the other option was to use a regenerator which reduces the size of the combustion chamber. The regenerator utilizes the waste heat to preheat the compressed air before the combustion chamber. In addition, the efficiency can be improved with compressor intercooling and turbine reheating. In this paper, four gas turbine power plant configurations were investigated and optimized to find the maximum possible efficiency for each configuration. The configurations are (1) basic gas turbine, (2) combined cycle, (3) advanced combined cycle and (4) gas turbine with regenerator, intercooler and reheater. The power plants were modeled in EES software and the basic model was validated against vendor’s data (GE E-class gas turbine Model 7E) with good agreement. Maximum discrepancy was only 3%. The optimization was carried out using conjugate directions method and improvements in the baseline design were as high as 25%. The paper presents the modeling work, baseline designs, optimization and analysis of the optimization results using T-s diagrams. The efficiency of the optimized configurations varied from 49% up 65%.

Author(s):  
P. Shukla ◽  
M. Izadi ◽  
P. Marzocca ◽  
D. K. Aidun

The objective of this paper is to evaluate methods to increase the efficiency of a gas turbine power plant. Advanced intercooled gas turbine power plants are quite efficient, efficiency reaching about 47%. The efficiency could be further increased by recovering wasted heat. The system under consideration includes an intercooled gas turbine. The heat is being wasted in the intercooler and a temperature drop happens at the exhaust. For the current system it will be shown that combining the gas cycle with steam cycle and removing the intercooler will increase the efficiency of the combined cycle power plant up to 60%. In combined cycles the efficiency depends greatly on the exhaust temperature of the gas turbine and the higher gas temperature leads to the higher efficiency of the steam cycle. The analysis shows that the latest gas turbines with the intercooler can be employed more efficiently in a combined cycle power application if the intercooler is removed from the system.


Author(s):  
Alberto Vannoni ◽  
Andrea Giugno ◽  
Alessandro Sorce

Abstract Renewable energy penetration is growing, due to the target of greenhouse-gas-emission reduction, even though fossil fuel-based technologies are still necessary in the current energy market scenario to provide reliable back-up power to stabilize the grid. Nevertheless, currently, an investment in such a kind of power plant might not be profitable enough, since some energy policies have led to a general decrease of both the average price of electricity and its variability; moreover, in several countries negative prices are reached on some sunny or windy days. Within this context, Combined Heat and Power systems appear not just as a fuel-efficient way to fulfill local thermal demand, but also as a sustainable way to maintain installed capacity able to support electricity grid reliability. Innovative solutions to increase both the efficiency and flexibility of those power plants, as well as careful evaluations of the economic context, are essential to ensure the sustainability of the economic investment in a fast-paced changing energy field. This study aims to evaluate the economic viability and environmental impact of an integrated solution of a cogenerative combined cycle gas turbine power plant with a flue gas condensing heat pump. Considering capital expenditure, heat demand, electricity price and its fluctuations during the whole system life, the sustainability of the investment is evaluated taking into account the uncertainties of economic scenarios and benchmarked against the integration of a cogenerative combined cycle gas turbine power plant with a Heat-Only Boiler.


2000 ◽  
Author(s):  
Duck-Jin Kim ◽  
Hyun-Soo Lee ◽  
Ho-Young Kwak ◽  
Jae-Ho Hong

Abstract Exegetic and thermoeconomic analysis were performed for a 500-MW combined cycle plant and a 137-MW steam power plant without decomposition of exergy into thermal and mechanical exergy. A unit cost was assigned to a specific exergy stream of matter, regardless of its condition or state in this analysis. The calculated costs of electricity were almost same within 0.5% as those obtained by the thermoeconomic analysis with decomposition of the exergy stream for the combined cycle plant, which produces the same kind of product. Such outcome indicated that the level at which the cost balances are formulated does not affect the result of thermoeconomic analysis, that is somewhat contradictory to that concluded previously. However this is true for the gas-turbine cogeneration plant which produces different kinds of products, electricity and steam whose unit costs are dominantly affected by the mechanical and thermal exergy respectively.


2021 ◽  
Vol 143 (4) ◽  
Author(s):  
Alberto Vannoni ◽  
Andrea Giugno ◽  
Alessandro Sorce

Abstract Renewable energy penetration is growing, due to the target of greenhouse-gas-emission reduction, even though fossil fuel-based technologies are still necessary in the current energy market scenario to provide reliable back-up power to stabilize the grid. Nevertheless, currently, an investment in such a kind of power plant might not be profitable enough, since some energy policies have led to a general decrease of both the average single national price of electricity (PUN) and its variability; moreover, in several countries, negative prices are reached on some sunny or windy days. Within this context, combined heat and power (CHP) systems appear not just as a fuel-efficient way to fulfill local thermal demand but also as a sustainable way to maintain installed capacity able to support electricity grid reliability. Innovative solutions to increase both the efficiency and flexibility of those power plants, as well as careful evaluations of the economic context, are essential to ensure the sustainability of the economic investment in a fast-paced changing energy field. This study aims to evaluate the economic viability and environmental impact of an integrated solution of a cogenerative combined cycle gas turbine power plant with a flue gas condensing heat pump. Considering capital expenditure, heat demand, electricity price, and its fluctuations during the whole system life, the sustainability of the investment is evaluated taking into account the uncertainties of economic scenarios and benchmarked against the integration of a cogenerative combined cycle gas turbine power plant with a heat-only boiler (HOB).


2018 ◽  
Vol 31 ◽  
pp. 01011
Author(s):  
Isworo Pujotomo

Gas has great potential to be converted into electrical energy. Indonesia has natural gas reserves up to 50 years in the future, but the optimization of the gas to be converted into electricity is low and unable to compete with coal. Gas is converted into electricity has low electrical efficiency (25%), and the raw materials are more expensive than coal. Steam from a lot of wasted gas turbine, thus the need for utilizing exhaust gas results from gas turbine units. Combined cycle technology (Gas and Steam Power Plant) be a solution to improve the efficiency of electricity. Among other Thermal Units, Steam Power Plant (Combined Cycle Power Plant) has a high electrical efficiency (45%). Weakness of the current Gas and Steam Power Plant peak burden still using fuel oil. Compressed Natural Gas (CNG) Technology may be used to accommodate the gas with little land use. CNG gas stored in the circumstances of great pressure up to 250 bar, in contrast to gas directly converted into electricity in a power plant only 27 bar pressure. Stored in CNG gas used as a fuel to replace load bearing peak. Lawyer System on CNG conversion as well as the power plant is generally only used compressed gas with greater pressure and a bit of land.


Author(s):  
Edgar Vicente Torres González ◽  
Raúl Lugo Leyte ◽  
Martín Salazar Pereyra ◽  
Helen Denise Lugo Méndez ◽  
Miguel Toledo Velázquez ◽  
...  

In this paper is carried out a comparison between a gas turbine power plant and a combined cycle power plant through exergetic and environmental indices in order to determine performance and sustainability aspects of a gas turbine and combined cycle plant. First of all, an exergetic analysis of the gas turbine and the combined is carried out then the exergetic and environmental indices are calculated for the gas turbine (case A) and the combined cycle (case B). The exergetic indices are exergetic efficiency, waste exergy ratio, exergy destruction factor, recoverable exergy ratio, environmental effect factor and exergetic sustainability. Besides, the environmental indices are global warming, smog formation and acid rain indices. In the case A, the two gas turbines generate 278.4 MW; whereas 415.19 MW of electricity power is generated by the combined cycle (case B). The results show that exergetic sustainability index for cases A and B are 0.02888 and 0.1058 respectively. The steam turbine cycle improves the overall efficiency, as well as, the reviewed exergetic indexes. Besides, the environmental indices of the gas turbines (case A) are lower than the combined cycle environmental indices (case B), since the combustion gases are only generated in the combustion chamber.


1980 ◽  
Author(s):  
J. Jermanok ◽  
R. E. Keith ◽  
E. F. Backhaus

A new 37-MW, single-shaft gas turbine power plant has been designed for electric power generation, for use in either simple-cycle or combined-cycle applications. This paper describes the design features, instrumentation, installation, test, and initial operation.


2021 ◽  
Vol 286 ◽  
pp. 04013
Author(s):  
George Iulian Balan ◽  
Octavian Narcis Volintiru ◽  
Ionut Cristian Scurtu ◽  
Florin Ioniță ◽  
Mirela Letitia Vasile ◽  
...  

Vessels that have navigation routes in areas with ambient temperatures that can drop below + 5 [°C], with a relative humidity of over 65%, will have implemented technical solutions for monitoring and combating ice accumulations in the intake routes of gas turbine power plants. Because gas turbines are not designed and built to allow the admission of foreign objects (in this case - ice), it is necessary to avoid the accumulation of ice through anti-icing systems and not to melt ice through defrost systems. Naval anti-icing systems may have as a source of energy flow compressed air, supersaturated steam, exhaust gases, electricity or a combination of those listed. The monitoring and optimization of the operation of the anti-icing system gives the gas turbine power plant an operation as close as possible to the normal regimes stipulated in the ship's construction or retrofit specification.


2010 ◽  
Vol 132 (12) ◽  
pp. 57-57
Author(s):  
Lee S. Langston

This article presents an overview of gas turbine combined cycle (CCGT) power plants. Modern CCGT power plants are producing electric power as high as half a gigawatt with thermal efficiencies approaching the 60% mark. In a CCGT power plant, the gas turbine is the key player, driving an electrical generator. Heat from the hot gas turbine exhaust is recovered in a heat recovery steam generator, to generate steam, which drives a steam turbine to generate more electrical power. Thus, it is a combined power plant burning one unit of fuel to supply two sources of electrical power. Most of these CCGT plants burn natural gas, which has the lowest carbon content of any other hydrocarbon fuel. Their near 60% thermal efficiencies lower fuel costs by almost half compared to other gas-fired power plants. Their installed capital cost is the lowest in the electric power industry. Moreover, environmental permits, necessary for new plant construction, are much easier to obtain for CCGT power plants.


Sign in / Sign up

Export Citation Format

Share Document