scholarly journals Reproducibility in pelvic floor biometric parameters of nulliparous women assessed by translabial three-dimensional ultrasound using Omniview reformatting technique.

2016 ◽  
Vol 18 (3) ◽  
pp. 345 ◽  
Author(s):  
Zsuzsanna Ilona Katalin Jármy-Di Bella ◽  
Edward Araujo Júnior ◽  
Claudinei Alves Rodrigues ◽  
Luiza Torelli ◽  
Wellington P. Martins ◽  
...  

Aim: To assess the reproducibility of pelvic floor biometric parameters by translabial three-dimensional ultrasound compared with the OmniView® reformatting technique. Material and methods: We performed a cross-sectional study involving 47 nulliparous women without symptoms of pelvic floor dysfunction. The hiatal area and right pubovisceral muscle width measurements were performed in the axial plane using both 3D ultrasound in the rendering mode and OmniView® techniques. To determine the occurrence of standardized error between examiners and the two sonographic methods, the paired t-test was used. The intra- and inter-observer reliability and agreement were estimated by concordance correlation coefficient (CCC) and limits of agreement, respectively. Results: We did not observe significant statistical differences among both measurements performed by the first examiner, both examiners and both methods in the assessment of the hiatal area; however, the measurements of the right pubovisceral muscle were significantly lower using OmniView®. The intra-observer reliability was good in the evaluation of all pelvic floor parameters; however, the inter-observer reliability was good only to the 3D rendering mode (CCC=0.87). The intra-observer agreement was good in the assessment of all pelvic floor parameters; however, the inter-observer agreement was found to be good only when 3DUS in the rendering mode was used (<±15%). Conclusion: Both 3D ultrasound in the rendering mode and OmniView® reformatting techniques were concordant in the assessment of pelvic floor parameters; however, the 3D ultrasound rendering in the mode demonstrated better inter-observer reliability and agreement.

2014 ◽  
Vol 44 (S1) ◽  
pp. 22-23
Author(s):  
A. Youssef ◽  
L. Cariello ◽  
E. Montaguti ◽  
T. Ghi ◽  
O. Sanlorenzo ◽  
...  

Author(s):  
Shahida Naghma ◽  
Achla Batra ◽  
Deepak Kumar

Background: The pelvic floor muscles (PFM) play an important role in supporting the pelvic and abdominal organs and controlling urinary and fecal continence, in addition to their role in the sexual function. The objective of this study was to compare pelvic floor muscle strength in primiparous 6 months after delivery and nulliparous women, to evaluate pelvic floor dysfunction (PFD) in these women and to find the association of PFD with pelvic floor muscle strength (PFMS).Methods: A total of 100 women were recruited in the cross-sectional study which included 28 nulliparous and 72 primiparous women 6 months after delivery. The assessment included general physical examination (GPE), POP-Q and assessment of pelvic floor muscle strength by modified oxford score and perineometer.Results: Endurance of PFMS measured by duration of contraction and number of contractions/min was higher in nulliparous. Mean of the duration of contraction was significantly higher in nulliparous group as compared to primipara i.e., 28.61 seconds and 23.9 seconds in nulliparous and primiparous group respectively (p=0.005). Mean of the number of contractions performed in one minute was significantly higher in nulliparous group as compared to primipara i.e., 31.04 and 19.97 in nulliparous and primiparous group respectively (p<0.0001). None of the nulliparous women had any PFD symptoms, while 4.17% of the primiparous patients had PFD in the form of bladder symptoms and 1.39% of them had PFD in the form bowel symptoms. Vaginal squeeze pressure was found to be affected by mode of delivery. It was lowest in instrumental delivery. It was 39.78±13.33 cmH20 in vaginal delivery, 51.42±12.88 cmH2O in Caesarean section and 31.67±14.36 cmH2O in instrumental delivery (p-0.039).Conclusions: Endurance of PFMS measured by duration of contraction and number of contractions/min was higher in nulliparous. Vaginal squeeze pressure was found to be affected by mode of delivery. It was lowest in instrumental delivery.


2020 ◽  
Vol 10 (6) ◽  
pp. 1370-1373
Author(s):  
Cheng Peng ◽  
Beihua Kong

Objective: During pregnancy and childbirth, a series of remodeling processes may lead to the occurrence of pelvic floor dysfunction. Our aim was to explore the influence of different delivery methods on pelvic floor in primipara after delivery through three-dimensional (3D) ultrasound examination. Method: A total of 48 primiparas were selected as the study object. Among which, 21 primiparas underwent cesarean section were selected as observation group, 27 primiparas in vaginal delivery were selected as the control group. The 3D ultrasound examination of pelvic floor was carried out 6–8 weeks postnatally to observe and compare the prolapse of anterior, middle and posterior pelvic organs of parturient women in Valsalva movement. The posterior ureterovesical angel (PUA), urethral tilt angel (UTA), cervical mouth position (CMP), and bladder neck position (BNP) were measured. The changes of hiatus of levator ani muscle in patients with anal constriction, rest and Valsalva were observed and measured. Result: Compared with the data in control group, the number of cases of anterior, middle and posterior pelvic organ exfoliation in observation group was lesser, the UTA and BNP were higher, the CMP was lower, and the area of hiatus of levator ani muscle was smaller both at the time of calm, contraction and Valsalva movements. Conclusion: The damage of pelvic floor in primipara during transvaginal delivery is great. The 3D ultrasound is an objective and simple imaging method to screen the diseases of pelvic floor dysfunction.


2014 ◽  
Vol 44 (S1) ◽  
pp. 23-23
Author(s):  
A. Youssef ◽  
E. Montaguti ◽  
L. Cariello ◽  
T. Ghi ◽  
A. Piastra ◽  
...  

Climacteric ◽  
2018 ◽  
Vol 21 (5) ◽  
pp. 462-466 ◽  
Author(s):  
D. A. S. Bocardi ◽  
V. S. Pereira-Baldon ◽  
C. H. J. Ferreira ◽  
M. A. Avila ◽  
A. C. S. Beleza ◽  
...  

Author(s):  
Beatriz Souza Harada ◽  
Thainá Tolosa De Bortolli ◽  
Letícia Carnaz ◽  
Marta Helena Souza De Conti ◽  
Adoniz Hijaz ◽  
...  

2013 ◽  
Vol 54 (1) ◽  
pp. 75-82 ◽  
Author(s):  
So Young Park ◽  
Ji Seon Park ◽  
Wook Jin ◽  
Kee Hyung Rhyu ◽  
Kyung Nam Ryu

Background Magnetic resonance (MR) arthrography is the ideal imaging modality for the acetabular labrum. Three-dimensional (3D) fast spin-echo (FSE) sequences have similar diagnostic performance as two-dimensional (2D) conventional MR imaging for ligaments, menisci, or bone marrow edema in the knee. Purpose To compare the diagnostic accuracy and inter-observer reliability of 3D intermediate-weighted FSE sequence and 2D FSE sequences for the diagnosis of acetabular labral tears. Material and Methods Institutional review board approval was obtained and informed consent was waived for 45 patients (47 hips) who underwent 3D and 2D MR arthrography and subsequent arthroscopic surgery. The 3D sequences were performed using volumetric intermediate-weighted fast spin-echo imaging with fat suppression (voxel size, 0.6 × 0.6 × 1.2 mm; imaging time, 6 min 38 s). Labral tear was retrospectively and independently evaluated by two radiologists in four areas of the labrum (anterosuperior, posterosuperior, anteroinferior, and posteroinferior) on 3D and 2D FSE sequences. Statistical differences between the sensitivity and specificity of the methods were analyzed with the McNemar test, using arthroscopic findings as the reference standard. Inter-observer agreement was calculated using kappa statistics. Results Arthroscopic findings confirmed labral tears at 40 anterosuperior, 23 posterosuperior, 0 anteroinferior, and 2 posteroinferior quadrants. Sensitivity and specificity were 74% and 89% for 2D FSE sequences, and 78% and 92% for 3D FSE sequences, respectively. Sensitivities and specificities for the methods were not different statistically (P > 0.05). Inter-observer agreement for labral tear was substantial for 2D FSE sequences (k = 0.774) and almost perfect for 3D FSE sequences (k = 0.842). Conclusion 3D intermediate-weighted FSE MR arthrography is excellent for diagnosing acetabular labral tears. Sensitivity, specificity, and inter-observer reliability were similar to conventional 2D MR arthrography. For evaluation of the labrum, 3D FSE MR arthrography is more time-efficient than 2D FSE MR arthrography.


2021 ◽  
Author(s):  
Carlos Izaias Sartorão Filho ◽  
Fabiane Affonso Pinheiro ◽  
Luiz Takano ◽  
Raghavendra Hallur Lakshmana Shetty ◽  
Sthefanie K. Nunes ◽  
...  

Abstract Background Gestational Diabetes Mellitus and long-term urinary incontinence (UI) have a severe impact on women's health. New methods to identify pregnant predictor risk factors of UI are needed. Our study investigated clinical and pelvic floor 3D-ultrasound markers in pregnant women at the second and third trimesters to predict 6-18 months postpartum UI. Methods This ongoing prospective cohort study included one hundred five nulliparous pregnant women with universal GDM screening and diagnosis, treated with nutritional and healthy lifestyle intervention. Pelvic floor 3DUltrasound was performed at the second and third trimesters of gestation. Clinical and pelvic floor 3DUltrasound biometry were collected. The ICIQ-SF and ISI questionnaires for UI were applied in the third trimester and 6-18 months postpartum. We performed univariate analysis (P<.20) to extract risk factors variables and multivariate logistic regression analysis (P<.05) to obtain the adjusted relative ratio for 6-18 months postpartum UI. Results In a preliminary result, a total of 93 participants concluded the follow-up. Using the variables obtained by the univariate analysis and after the adjustments for potential confounders, logistic regression analysis revealed that Gestational Diabetes Mellitus exposure was a strong and independent risk factor for 6-18 months postpartum UI (Adjusted RR 8.088; 95%CI 1.17-55.87; P:.034). In addition, higher hiatal area distension at rest from the second to the third trimester was negatively correlated with 6-18 months postpartum UI (Adjusted RR 0.966; 95%CI 0.93-0.99; P: .023). Conclusion Gestational Diabetes Mellitus was positively correlated with 6-18 months postpartum UI, and a higher hiatal area distension was negatively correlated with 6-18 months postpartum UI development. Trial registration: Regulatory approval was obtained from the Institutional Review Board (number 1.716.895) by “Botucatu Medical School of São Paulo State University (Unesp)” Ethics Committee.


Sign in / Sign up

Export Citation Format

Share Document