Wavelength stabilized fiber coupled modules at 79x nm, 88x nm, and 97x nm with up to 600W output power based on single emitters

Author(s):  
Tobias Könning ◽  
Sandra Ahlert ◽  
Jan-Niklas Weimar ◽  
Ruth Steinborn-Knuth ◽  
florian Ahnepohl ◽  
...  
Keyword(s):  
2019 ◽  
Vol 18 (3) ◽  
pp. 118
Author(s):  
Anderson Pontes Morales ◽  
Felipe Sampaio-Jorge ◽  
Thiago Barth ◽  
Alessandra Alegre De Matos ◽  
Luiz Felipe Da Cruz Rangel ◽  
...  

Introduction: The aim of this study was to test the hypothesis that caffeine supplementation (6 mg·kg-1 body mass) for 4-days, followed by acute intake, would impact five male triathletes output power after performed submaximal intensity exercise. Methods: This was a randomized, double-blind, placebo-controlled crossover study, placebo (4-day) - placebo (acute) PP, placebo (4-days) -caffeine (acute) PC, and caffeine (4-day) - caffeine (acute) CC. Participants abstained from dietary caffeine sources for 4 days and ingested capsules containing either placebo or caffeine (6 mg.kg-1 body mass day in one absorption). The acute trials the capsules containing placebo or caffeine (6 mg.kg-1 body mass day in one absorption) were ingested 60min before completing exercise in a treadmill for 40min (80% VO2max) and to perform the Wingate test. Results: Blood lactate was determined before, 60min after ingestion, and immediately after the exercise on the treadmill, the Wingate test, and after the recovery (10-min). CC and PC trials did not change the cardiopulmonary variables (P>0.05) and the anaerobic power variables (peak/mean power output and fatigue index) (P>0.05). The PC trial compared with PP promoted improvements in the curve power output in 2 sec by 31.19% (large effect-size d = 1.08; P<0.05) and 3 sec by 20% (large effect-size d = 1.19; P<0.05). A 10min recovery was not sufficient to reduce blood lactate concentration in the PC trial compared with PP (PC, 13.73±2.66 vs. PP, 10.26±1.60 mmol.L-1; P<0.05, respectively) (P<0.05). Conclusion: In conclusion, these results indicate that caffeine supplementation (6 mg·kg-1 body mass) for 4 days, followed by acute ingestion, did not impact the triathletes output power after performed submaximal intensity exercise. Nutritional interventions may help researchers and athletes to adapt strategies for manipulating caffeine use.Key-words: caffeine metabolism, Wingate test, blood lactate, performance.


Author(s):  
Clarence Rebello ◽  
Ted Kolasa ◽  
Parag Modi

Abstract During the search for the root cause of a board level failure, all aspects of the product must be revisited and investigated. These aspects encompass design, materials, and workmanship. In this discussion, the failure investigation involved an S-Band Power Amplifier assembly exhibiting abnormally low RF output power where initial troubleshooting did not provide a clear cause of failure. A detailed fault tree drove investigations that narrowed the focus to a few possible root causes. However, as the investigation progressed, multiple contributors were eventually discovered, some that were not initially considered.


Author(s):  
Gang Li ◽  
Binren Zhang

Background: Electromagnetic detection is an important method of geophysical exploration. The transmitting system is an important part of the electromagnetic detection equipment. Methods: The general topologies of a transmitting system for EM instrument are analyzed. The basic principle of EM detection is interpreted. In order to improve the output power and give consideration to the dynamic performance, an electromagnetic transmitting system based on the tri-state boost converter is proposed in this paper. Results: The principle of the proposed transmitting system is analyzed. The topology of the proposed transmitting system is illustrated and the working modes of tri-state boost converter are given. Conclusion: The simulation model is established and the simulation experiment is carried out to verify the feasibility of the new electromagnetic transmitting system.


2020 ◽  
Vol 96 (3s) ◽  
pp. 321-324
Author(s):  
Е.В. Ерофеев ◽  
Д.А. Шишкин ◽  
В.В. Курикалов ◽  
А.В. Когай ◽  
И.В. Федин

В данной работе представлены результаты разработки СВЧ монолитной интегральной схемы шестиразрядного фазовращателя и усилителя мощности диапазона частот 26-30 ГГц. СКО ошибки по фазе и амплитуде фазовращателя составили 1,2 град. и 0,13 дБ соответственно. Максимальная выходная мощность и КПД по добавленной мощности усилителя в точке сжатия Ку на 1 дБ составили 30 дБм и 20 % соответственно. This paper describes the design, layout, and performance of 6-bit phase shifter and power amplifier monolithic microwave integrated circuit (MMIC), 26-30 GHz band. Phase shifter MMIC has RMS phase error of 1.2 deg. And RMD amplitude error is 0.13 dB. MMIC power amplifier has output power capability of 30 dBm at 1 dB gain compression (P-1dB) and PAE of 20 %.


Sign in / Sign up

Export Citation Format

Share Document