scholarly journals Visualization of vermilion degradation using pump-probe microscopy

2019 ◽  
Vol 5 (6) ◽  
pp. eaaw3136 ◽  
Author(s):  
Jin Yu ◽  
Warren S. Warren ◽  
Martin C. Fischer

Here, we demonstrate the use of pump-probe microscopy for high-resolution studies of vermilion degradation. Vermilion (mostly α-HgS), an important red pigment used in historical paintings, blackens over time, and metallic Hg and β-HgS have been implicated as possible degradation products. Conventional analysis techniques have trouble differentiating α- and β-HgS with sufficiently high spatial resolution. However, pump-probe microscopy can differentiate metallic mercury, α- and β-HgS, and map each distribution on the microscopic scale. We studied artificial degradation of α-HgS; femtosecond-pulsed laser irradiation induces an irreversible phase shift of α- to β-HgS, in which the initial presence of β-HgS grains can increase the rate of conversion in their vicinity. Continuous ultraviolet exposure instead generates both liquid Hg and β-HgS, with a conversion rate that increases with elevated temperatures. Last, we reveal the presence of β-HgS as a natural degradation product in discolored vermilion layers in a 14th century Italian painting.

1999 ◽  
Vol 2 (03) ◽  
pp. 271-280 ◽  
Author(s):  
Ekrem Kasap ◽  
Kun Huang ◽  
Than Shwe ◽  
Dan Georgi

Summary The formation-rate-analysis (FRASM) technique is introduced. The technique is based on the calculated formation rate by correcting the piston rate with fluid compressibility. A geometric factor is used to account for irregular flow geometry caused by probe drawdown. The technique focuses on the flow from formation, is applicable to both drawdown and buildup data simultaneously, does not require long buildup periods, and can be implemented with a multilinear regression, from which near-wellbore permeability, p * and formation fluid compressibility are readily determined. The field data applications indicate that FRA is much less amenable to data quality because it utilizes the entire data set. Introduction A wireline formation test (WFT) is initiated when a probe from the tool is set against the formation. A measured volume of fluid is then withdrawn from the formation through the probe. The test continues with a buildup period until pressure in the tool reaches formation pressure. WFTs provide formation fluid samples and produce high-precision vertical pressure profiles, which, in turn, can be used to identify formation fluid types and locate fluid contacts. Wireline formation testing is much faster compared with the regular pressure transient testing. Total drawdown time for a formation test is just a few seconds and buildup times vary from less than a second (for permeability of hundreds of millidarcy) to half a minute (for permeability of less than 0.1 md), depending on system volume, drawdown rate, and formation permeability. Because WFT tested volume can be small (a few cubic centimeters), the details of reservoir heterogeneity on a fine scale are given with better spatial resolution than is possible with conventional pressure transient tests. Furthermore, WFTs may be preferable to laboratory core permeability measurements since WFTs are conducted at in-situ reservoir stress and temperature. Various conventional analysis techniques are used in the industry. Spherical-flow analysis utilizes early-time buildup data and usually gives permeability that is within an order of magnitude of the true permeability. For p* determination, cylindrical-flow analysis is preferred because it focuses on late-time buildup data. However, both the cylindrical- and spherical-flow analyses have their drawbacks. Early-time data in spherical-flow analysis results in erroneous p* estimation. Late-time data are obtained after long testing times, especially in low-permeability formations; however, long testing periods are not desirable because of potential tool "sticking" problems. Even after extended testing times, the cylindrical-flow period may not occur or may not be detectable on WFTs. When it does occur, permeability estimates derived from the cylindrical-flow period may be incorrect and their validity is difficult to judge. New concepts and analysis techniques, combined with 3-D numerical studies, have recently been reported in the literature.1–7 Three-dimensional numerical simulation studies1–6 have contributed to the diagnosis of WFT-related problems and the improved analysis of WFT data. The experimental studies7 showed that the geometric factor concept is valid for unsteady state probe pressure tests. This study presents the FRA technique8 that can be applied to the entire WFT where a plot for both drawdown and buildup periods renders straight lines with identical slopes. Numerical simulation studies were used to generate data to test both the conventional and the FRA techniques. The numerical simulation data are ideally suited for such studies because the correct answer is known (e.g., the input data). The new technique and the conventional analysis techniques are also applied to the field data and the results are compared. We first review the theory of conventional analysis techniques, then present the FRA technique for combined drawdown and buildup data. A discussion of the numerical results and the field data applications are followed by the conclusions. Analysis Techniques It has been industry practice to use three conventional techniques, i.e., pseudo-steady-state drawdown (PSSDD), spherical and cylindrical-flow analyses, to calculate permeability and p* Conventional Techniques Pseudo-Steady-State Drawdown (PSSDD). When drawdown data are analyzed, it is assumed that late in the drawdown period the pressure drop stabilizes and the system approaches to a pseudo-steady state when the formation flow rate is equal to the drawdown rate. PSSDD permeability is calculated from Darcy's equation with the stabilized (maximum) pressure drop and the flowrate resulting from the piston withdrawal:9–11 $$k {d}=1754.5\left({q\mu \over r {i}\Delta p {{\rm max}}}\right),\eqno ({\rm 1})$$where kd=PSSDD permeability, md. The other parameters are given in Nomenclature.


2004 ◽  
Vol 99-100 ◽  
pp. 65-72
Author(s):  
Yuri S. Kaganovsky ◽  
I. Antonov ◽  
M. Rosenbluh ◽  
J. Ihlemann ◽  
A.A. Lipovskii

Two types of silver-doped glass were used for direct laser recording of 2D and 3D photonic crystals. The first contained a diffusion layer (20 microns thick) with embedded silver nanoclusters of 20-nm average radius. 2D and 3D photonic crystals of submicron lattice parameters were fabricated by nanosecond pulsed laser irradiation (l, = 355 nm) using four or five coherent intersecting beams. Under irradiation the clusters absorbing light energy are heated to high temperatures and become mobile due to the formation of liquid shells around them. Adjacent clusters move towards each other and towards the irradiated surface under local temperature gradients, form agglomerates and merge in periodically located "spots" of high light intensity in the interference field. The second type of glass, photosensitive to UV irradiation, contained in the bulk Ag+ and Ce3+ ions. Under UV irradiation excited electrons passed from Ce3+ to Ag+. The Ag atoms became neutral and under subsequent heat treatment of the glass at elevated temperatures have a tendency to form nanoclusters, thus “developing” the UV recorded patterns. Using nanosecond pulsed irradiation of 308 nm we have recorded 3D photonic crystals in the bulk of such glass.


2017 ◽  
Vol 53 (04) ◽  
pp. 234-237
Author(s):  
Jyotsna Kailashiya

ABSTRACTPlatelet-derived microparticles (PMPs) are often used as marker of platelet activation and their count in blood has been found to be significantly associated with many diseases like myocardial infarction, stroke, venous thrombo-embolism etc. PMPs have been proposed as potential biomarkers for these conditions. Biosensors are newer analytical tools, being developed for convenient and cost effective analysis. For PMPs analysis, biosensors offer many advantages over conventional analysis techniques. This mini review compiles designs and techniques of reported biosensors based on antibody capturing for analysis of PMPs.


2016 ◽  
Vol 24 (18) ◽  
pp. 20868 ◽  
Author(s):  
Eric S. Massaro ◽  
Andrew H. Hill ◽  
Casey L. Kennedy ◽  
Erik M. Grumstrup

2017 ◽  
Author(s):  
Scott R. Domingue ◽  
Adam J. Chicco ◽  
Randy A. Bartels ◽  
Jesse W. Wilson

2017 ◽  
Vol 21 (2) ◽  
pp. 137-144 ◽  
Author(s):  
Francisco E. Robles ◽  
Sanghamitra Deb ◽  
Martin C. Fischer ◽  
Warren S. Warren ◽  
Maria Angelica Selim

2014 ◽  
Vol 111 (5) ◽  
pp. 1708-1713 ◽  
Author(s):  
Tana Elizabeth Villafana ◽  
William P. Brown ◽  
John K. Delaney ◽  
Michael Palmer ◽  
Warren S. Warren ◽  
...  

2014 ◽  
Vol 118 (16) ◽  
pp. 8634-8640 ◽  
Author(s):  
Erik M. Grumstrup ◽  
Michelle M. Gabriel ◽  
Emma M. Cating ◽  
Christopher W. Pinion ◽  
Joseph D. Christesen ◽  
...  

2019 ◽  
Vol 44 (16) ◽  
pp. 4083 ◽  
Author(s):  
Chenyang Wen ◽  
Fu Feng ◽  
Mindan Ren ◽  
Michael G. Somekh ◽  
Ni Zhao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document