scholarly journals Altered Enzyme-Linked Immunosorbent Assay Immunoglobulin M (IgM)/IgG Optical Density Ratios Can Correctly Classify All Primary or Secondary Dengue Virus Infections 1 Day after the Onset of Symptoms, when All of the Viruses Can Be Isolated

2006 ◽  
Vol 13 (9) ◽  
pp. 1044-1051 ◽  
Author(s):  
Andrew K. I. Falconar ◽  
Elsa de Plata ◽  
Claudia M. E. Romero-Vivas

ABSTRACT We compared dengue virus (DV) isolation rates and tested whether acute primary (P) and acute/probable acute secondary (S/PS) DV infections could be correctly classified serologically when the patients' first serum (S1) samples were obtained 1 to 3 days after the onset of symptoms (AOS). DV envelope/membrane protein-specific immunoglobulin M (IgM) capture and IgG capture enzyme-linked immunosorbent assay (ELISA) titrations (1/log10 1.7 to 1 log10 6.6 dilutions) were performed on 100 paired S1 and S2 samples from suspected DV infections. The serologically confirmed S/PS infections were divided into six subgroups based on their different IgM and IgG responses. Because of their much greater dynamic ranges, IgG/IgM ELISA titer ratios were more accurate and reliable than IgM/IgG optical density (OD) ratios recorded at a single cutoff dilution for discriminating between P and S/PS infections. However, 62% of these patients' S1 samples were DV IgM and IgG titer negative (<ODmax/2 titer threshold), and in 35% of the S/PS infections, the patients' S1 and S2 samples were IgM titer negative. The IgM OD values were, however, much higher than those of IgG in the S1 samples of many of these, and the other, S/PS infections. This necessitated using higher (≥2.60 and <2.60) discriminatory IgM/IgG OD (DOD) ratios on these S1 samples than those published previously to correctly classify the highest percentage of these P and S/PS infections. The DV isolation rate was highest (12/12; 100%) using IgG and IgM titer-negative S1 samples collected 1 day AOS, when 100% of them were correctly classified as P or S/PS infections using these higher DOD ratios.

2003 ◽  
Vol 10 (4) ◽  
pp. 622-630 ◽  
Author(s):  
Pei-Yun Shu ◽  
Li-Kuang Chen ◽  
Shu-Fen Chang ◽  
Yi-Yun Yueh ◽  
Ling Chow ◽  
...  

ABSTRACT We have found that NS1 serotype-specific immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) can be used to differentiate primary and secondary dengue virus infections. This is due to the fact that the NS1-specific IgG antibody cannot be detected before day 9 of illness for primary infection, so the NS1-specific IgG antibodies measured in acute-phase sera must come from previous infection. Comparison of NS1 serotype-specific IgG ELISA with envelope- and membrane-specific capture IgM and IgG ELISA in the differentiation of primary and secondary dengue virus infections showed good correlation (95.90% agreement). Most important, we have found that the serotype of the dengue virus from the majority of patients with primary infection could be correctly identified when convalescent-phase or postinfection sera were analyzed by NS1 serotype-specific IgG ELISA. These findings suggested that NS1 serotype-specific IgG ELISA could be reliably applied for serodiagnosis and seroepidemiological study of dengue virus infection.


1999 ◽  
Vol 37 (11) ◽  
pp. 3738-3741 ◽  
Author(s):  
Andrea J. Cuzzubbo ◽  
Timothy P. Endy ◽  
David W. Vaughn ◽  
Tom Solomon ◽  
Ananda Nisalak ◽  
...  

A new commercial enzyme-linked immunosorbent assay (ELISA) for the diagnosis of Japanese encephalitis virus infections showed a sensitivity of 88% with sera and 81% with cerebrospinal fluid and a specificity of 97% with sera from patients with primary and secondary dengue virus infections. Specificity was 100% when samples from nonflavivirus infections were tested.


1999 ◽  
Vol 6 (5) ◽  
pp. 705-712 ◽  
Author(s):  
Andrea J. Cuzzubbo ◽  
David W. Vaughn ◽  
Ananda Nisalak ◽  
Tom Solomon ◽  
Siripen Kalayanarooj ◽  
...  

ABSTRACT The performances of the MRL dengue fever virus immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) and the PanBio Dengue Duo IgM capture and IgG capture ELISA were compared. Eighty sera from patients with dengue virus infections, 24 sera from patients with Japanese encephalitis (JE), and 78 sera from patients with nonflavivirus infections, such as malaria, typhoid, leptospirosis, and scrub typhus, were used. The MRL test showed superior sensitivity for dengue virus infections (94 versus 89%), while the PanBio test showed superior specificity for JE (79 versus 25%) and other infections (100 versus 91%). The PanBio ELISA showed better overall performance, as assessed by the sum of sensitivity and specificity (F value). When dengue virus and nonflavivirus infections were compared, F values of 189 and 185 were obtained for the PanBio and MRL tests, respectively, while when dengue virus infections and JE were compared, F values of 168 and 119 were obtained. The results obtained with individual sera in the PanBio and MRL IgM ELISAs showed good correlation, but this analysis revealed that the cutoff value of the MRL test was set well below that of the PanBio test. Comparing the sensitivity and specificity of the tests at different cutoff values (receiver-operator analysis) revealed that the MRL and PanBio IgM ELISAs performed similarly in distinguishing dengue virus from nonflavivirus infections, although the PanBio IgM ELISA showed significantly better distinction between dengue virus infections and JE. The implications of these findings for the laboratory diagnosis of dengue are discussed.


2003 ◽  
Vol 10 (2) ◽  
pp. 317-322 ◽  
Author(s):  
Angel Balmaseda ◽  
María G. Guzmán ◽  
Samantha Hammond ◽  
Guillermo Robleto ◽  
Carolina Flores ◽  
...  

ABSTRACT To evaluate alternative approaches to the serological diagnosis of dengue virus (DEN) infection, the detection of DEN-specific immunoglobulin M (IgM) and IgA antibodies in serum and saliva specimens was assessed in 147 patients with symptoms of DEN infection seen at the Ministry of Health in Nicaragua. Seventy-two serum samples were determined to be positive for anti-DEN antibodies by IgM capture enzyme-linked immunosorbent assay, the routine diagnostic procedure. Serum and saliva specimens were obtained from 50 healthy adults as additional controls. IgM was detected in the saliva of 65 of the 72 serum IgM-positive cases, 6 of the 75 serum IgM-negative cases, and none of the control group, resulting in a sensitivity of 90.3% and a specificity of 92.0% and demonstrating that salivary IgM is a useful diagnostic marker for DEN infection. Detection of IgA in serum may be another feasible alternative for the diagnosis of DEN infection, with serum IgA found in 68 (94.4%) of the IgM-positive cases. In contrast, detection of IgA in saliva was not found to be a useful tool for DEN diagnosis in the present study. Further studies of the kinetics of antibody detection in another set of 151 paired acute- and convalescent-phase serum samples showed that DEN-specific IgA antibodies were detected in more acute-phase samples than were IgM antibodies. Thus, we conclude that DEN-specific IgA in serum is a potential diagnostic target. Furthermore, given that saliva is a readily obtainable, noninvasive specimen, detection of DEN-specific salivary IgM should be considered a useful, cheaper diagnostic modality with similar sensitivity and specificity to IgM detection in serum.


1998 ◽  
Vol 36 (11) ◽  
pp. 3359-3361 ◽  
Author(s):  
K. H. Chan ◽  
R. X. Luo ◽  
H. L. Chen ◽  
M. H. Ng ◽  
W. H. Seto ◽  
...  

A new immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) based on the recombinant Epstein-Barr virus (EBV) matrix protein was developed. Compared to indirect immunofluorescence for the detection of IgM antibody to the EBV capsid antigen on clinical specimens, the sensitivity and specificity of the new IgM ELISA were 96 and 96%, respectively.


1998 ◽  
Vol 36 (12) ◽  
pp. 3509-3513 ◽  
Author(s):  
Fabienne B. Bouche ◽  
Nicolaas H. C. Brons ◽  
Sophie Houard ◽  
Francois Schneider ◽  
Claude P. Muller

Recombinant hemagglutinin (H) of the measles virus (MV) expressed in a mammalian high-expression system based on the Semliki Forest virus replicon was used in an enzyme-linked immunosorbent assay (ELISA) for the detection of specific immunoglobulin M (IgM) and IgG in patients with acute-phase measles. One hundred twelve serum specimens from 70 patients with measles were analyzed. Case definition was based on a commercial IgM ELISA that utilizes MV-infected cells (MV-ELISA) (Enzygnost; Behring Diagnostics); the clinical criteria of the Centers for Disease Control and Prevention (Atlanta, Ga.); and/or the increase in hemagglutinin test titers, neutralization test titers, and levels of MV-specific IgG whenever paired sera were available. The initial time courses of the IgM signal after the onset of rash are similar in the H- and MV-ELISAs. On days 0 to 19, both ELISAs detected IgM in 67 of 68 (98.5%) sera. Average maximal levels of IgM seem to persist, however, about 10 days longer in the MV-ELISA (up to day 25) than in the H-ELISA (day 15). From days 20 to 29 and 30 to 59, the H-ELISA detected only 64.3 (9 of 14) and 19.2% (5 of 26), respectively, of sera that were IgM positive by MV-ELISA. At least up to day 30, the performance of the H-ELISA seemed to be similar to that reported for commercial ELISAs based on whole MV. Our results demonstrate that MV H-specific IgM can be used to diagnose most measles cases from a single serum specimen collected within 19 days after the onset of rash and that the recombinant protein used in this study is suitable for this purpose.


1979 ◽  
Vol 9 (4) ◽  
pp. 498-502
Author(s):  
D Dittmar ◽  
T J Cleary ◽  
A Castro

An enzyme-linked immunosorbent assay for the detection of antibodies to dengue virus is described. This method correlates well with a hemagglutination inhibition technique. The enzyme-linked immunosorbent assay can also be specific for human immunoglobulin M antibodies when a mu-chain-specific antiglobulin-enzyme conjugate and fractionated serum are employed. By using this technique, dengue immunoglobulin M antibodies were demonstrated in an infant suspected of having a recent dengue infection.


2003 ◽  
Vol 10 (1) ◽  
pp. 177-179 ◽  
Author(s):  
Harry E. Prince ◽  
Wayne R. Hogrefe

ABSTRACT During the 2001 U. S. West Nile virus (WNV) season, 163 specimens were reactive in an in-house WNV-specific immunoglobulin M (IgM) screening enzyme-linked immunosorbent assay (ELISA) and were referred to either the Centers for Disease Control and Prevention or the appropriate state public health laboratory (CDC/SPHL) for additional testing. CDC/SPHL supplied results for 124 specimens that could be further evaluated in-house: 70 specimens were nonreactive in the CDC/SPHL WNV-specific IgM screening assay, and 54 specimens were reactive. These specimens were used to evaluate a modified in-house WNV-specific IgM ELISA that incorporated background subtraction to identify nonspecific reactivity and thus improve assay specificity. Of the 70 CDC/SPHL nonreactive samples, 49 (70%) were nonreactive in the modified ELISA; of the 54 CDC/SPHL reactive samples, 51 (94%) were reactive in the modified ELISA. Confirmatory studies performed by CDC/SPHL indicated that 38 CDC/SPHL screen-reactive specimens represented true WNV infection; all 38 specimens were reactive in the modified in-house WNV-specific IgM ELISA. These findings demonstrate that an in-house ELISA system for WNV-specific IgM effectively identifies patients with WNV infection.


Sign in / Sign up

Export Citation Format

Share Document