Study of Deformation Phenomena in TRIP/TWIP Steels by Acoustic Emission and Scanning Electron Microscopy

2018 ◽  
Vol 119 (4) ◽  
pp. 388-395 ◽  
Author(s):  
M. L. Linderov ◽  
C. Segel ◽  
A. Weidner ◽  
H. Biermann ◽  
A. Yu. Vinogradov
1992 ◽  
Vol 273 ◽  
Author(s):  
William C. Revelos ◽  
Itzhak Roman

ABSTRACTA SiC/Ti-24AI-11 Nb (at. %) composite (30–35 vol. %) was thermally cycled in air and an inert environment between 150 °C and 815 °C for various cycle counts. Various hold times at maximum temperature were employed to determine timedependent effects on composite integrity. Laminate orientations investigated included: [0]4, [0]8, [90]4, [90]8 and [0/90]2S. Acoustic emission produced during thermal fatigue of selected specimens was employed to monitor damage progression. Post-cycling room temperature tension tests as well as optical and scanning electron microscopy were used to document damage, which was particularly acute when hold times at temperature were employed on tests performed in air. The roles of the environment, composite thickness, and off-axis fibers during thermal fatigue on the composite strength and integrity are discussed.


Author(s):  
P.S. Porter ◽  
T. Aoyagi ◽  
R. Matta

Using standard techniques of scanning electron microscopy (SEM), over 1000 human hair defects have been studied. In several of the defects, the pathogenesis of the abnormality has been clarified using these techniques. It is the purpose of this paper to present several distinct morphologic abnormalities of hair and to discuss their pathogenesis as elucidated through techniques of scanning electron microscopy.


Author(s):  
P.J. Dailey

The structure of insect salivary glands has been extensively investigated during the past decade; however, none have attempted scanning electron microscopy (SEM) in ultrastructural examinations of these secretory organs. This study correlates fine structure by means of SEM cryofractography with that of thin-sectioned epoxy embedded material observed by means of transmission electron microscopy (TEM).Salivary glands of Gromphadorhina portentosa were excised and immediately submerged in cold (4°C) paraformaldehyde-glutaraldehyde fixative1 for 2 hr, washed and post-fixed in 1 per cent 0s04 in phosphosphate buffer (4°C for 2 hr). After ethanolic dehydration half of the samples were embedded in Epon 812 for TEM and half cryofractured and subsequently critical point dried for SEM. Dried specimens were mounted on aluminum stubs and coated with approximately 150 Å of gold in a cold sputtering apparatus.Figure 1 shows a cryofractured plane through a salivary acinus revealing topographical relief of secretory vesicles.


Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Sign in / Sign up

Export Citation Format

Share Document