Spatial Vector–Scalar Structure of Low-Frequency Fields of Multipole Sources in Interference Maxima Zones

2020 ◽  
Vol 66 (3) ◽  
pp. 277-289
Author(s):  
G. N. Kuznetsov ◽  
A. N. Stepanov
1976 ◽  
Vol 75 (1) ◽  
pp. 17-28 ◽  
Author(s):  
M. E. Goldstein

A previous analysis of the acoustic radiation from multipole sources is extended to include additional components of the dipole and quadrupole sources. It is found that, unlike the components of the sources considered in the previous paper, the exponent of the Doppler factor now depends on the location of the sources within the jet.


Geophysics ◽  
1986 ◽  
Vol 51 (1) ◽  
pp. 148-163 ◽  
Author(s):  
Andrew L. Kurkjian ◽  
Shu‐Kong Chang

Acoustic well logging methods historically have been based on the excitation and reception of axisymmetric wave phenomena in a fluid‐filled wellbore. We consider the reception of nonsymmetric wave phenomena excited by acoustic multipole sources. The first three orders of multipoles are the monopole, dipole, and quadrupole, and we examine these particular sources in detail. Existing sonic tools make use of a monopole source, while more recently, both dipole and quadrupole sources have been explored. An exact frequency‐wavenumber domain representation of the acoustic field in the borehole due to a multipole source is formulated and numerical methods are used to compute synthetic space‐time domain waveforms. We consider wideband monopole, dipole, and quadrupole excitations with center frequencies of 1, 4, and 12 kHz, and treat both slow and fast formation models. Finally, we derive low‐frequency, far‐field asymptotic expressions for the monopole, dipole, and quadrupole waveforms. At frequencies such that the shear wavelength is on the order of the borehole diameter or less, the difference between the monopole, dipole, and quadrupole waveforms is primarily in the nature of the surface wave mode which they excite: the monopole excites a Stoneley, or tube mode; the dipole excites a flexural mode; and the quadrupole excites a screw mode. By comparison, the compressional and shear head waves and the trapped waveguide modes do not change as much as the order of the multipole is changed. At low frequencies, where the shear wavelength is much longer than the diameter of the hole, the monopole excites a dominating tube mode, while the dipole and quadrupole excites dominating shear waves. Low‐frequency asymptotic expressions for the waveforms agree well with the numerically computed waveforms.


1975 ◽  
Vol 70 (3) ◽  
pp. 595-604 ◽  
Author(s):  
M. E. Goldstein

We have obtained a closed-form solution for the sound radiation from multipole sources imbedded in an infinite cylindrical jet with an arbitrary velocity profile. It is valid in the limit where the wavelength is large compared with the jet radius. Simple formulae for the acoustic pressure field due to convected point sources are also obtained. The results show (in a simple way) how the mean flow affects the radiation pattern from the sources. For convected lateral quadrupoles it causes the exponentnof the Doppler factor (1 -Mcosθ)−nmultiplying the far-field pressure signal to be increased from the value of 3 used by Lighthill to 5.


Author(s):  
K. Hama

The lateral line organs of the sea eel consist of canal and pit organs which are different in function. The former is a low frequency vibration detector whereas the latter functions as an ion receptor as well as a mechano receptor.The fine structure of the sensory epithelia of both organs were studied by means of ordinary transmission electron microscope, high voltage electron microscope and of surface scanning electron microscope.The sensory cells of the canal organ are polarized in front-caudal direction and those of the pit organ are polarized in dorso-ventral direction. The sensory epithelia of both organs have thinner surface coats compared to the surrounding ordinary epithelial cells, which have very thick fuzzy coatings on the apical surface.


Author(s):  
Robert E. Nordquist ◽  
J. Hill Anglin ◽  
Michael P. Lerner

A human breast carcinoma cell line (BOT-2) was derived from an infiltrating duct carcinoma (1). These cells were shown to have antigens that selectively bound antibodies from breast cancer patient sera (2). Furthermore, these tumor specific antigens could be removed from the living cells by low frequency sonication and have been partially characterized (3). These proteins have been shown to be around 100,000 MW and contain approximately 6% hexose and hexosamines. However, only the hexosamines appear to be available for lectin binding. This study was designed to use Concanavalin A (Con A) and Ricinus Communis (Ricin) agglutinin for the topagraphical localization of D-mannopyranosyl or glucopyranosyl and D-galactopyranosyl or DN- acetyl glactopyranosyl configurations on BOT-2 cell surfaces.


Author(s):  
P. A. Marsh ◽  
T. Mullens ◽  
D. Price

It is possible to exceed the guaranteed resolution on most electron microscopes by careful attention to microscope parameters essential for high resolution work. While our experience is related to a Philips EM-200, we hope that some of these comments will apply to all electron microscopes.The first considerations are vibration and magnetic fields. These are usually measured at the pre-installation survey and must be within specifications. It has been our experience, however, that these factors can be greatly influenced by the new facilities and therefore must be rechecked after the installation is completed. The relationship between the resolving power of an EM-200 and the maximum tolerable low frequency interference fields in milli-Oerstedt is 10 Å - 1.9, 8 Å - 1.4, 6 Å - 0.8.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


Sign in / Sign up

Export Citation Format

Share Document